Refine
Year of publication
- 2010 (331) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (68)
- Fachbereich Wirtschaftswissenschaften (41)
- Fachbereich Elektrotechnik und Informationstechnik (36)
- IfB - Institut für Bioengineering (36)
- Fachbereich Energietechnik (35)
- Fachbereich Chemie und Biotechnologie (34)
- Fachbereich Maschinenbau und Mechatronik (31)
- Fachbereich Luft- und Raumfahrttechnik (24)
- Fachbereich Bauingenieurwesen (23)
- INB - Institut für Nano- und Biotechnologien (23)
Has Fulltext
- no (331) (remove)
Document Type
- Article (177)
- Conference Proceeding (67)
- Book (37)
- Part of a Book (20)
- Conference: Meeting Abstract (12)
- Patent (7)
- Report (4)
- Other (2)
- Contribution to a Periodical (1)
- Doctoral Thesis (1)
Keywords
- Geschichte (2)
- avalanche (2)
- Adsorbentien (1)
- Cardiovascular MRI (1)
- Cardiovascular Magnetic Resonance (1)
- Commercial Vehicle (1)
- Common Rail Injection System (1)
- Diesel Engine (1)
- Enzymatischer Ligninabbau (1)
- European Transient Cycle (1)
Objective
To investigate whether functional brain networks of epilepsy patients treated with antiepileptic medication differ from networks of healthy controls even during the seizure-free interval.
Methods
We applied different rules to construct binary and weighted networks from EEG and MEG data recorded under a resting-state eyes-open and eyes-closed condition from 21 epilepsy patients and 23 healthy controls. The average shortest path length and the clustering coefficient served as global statistical network characteristics.
Results
Independent on the behavioral condition, epileptic brains exhibited a more regular functional network structure. Similarly, the eyes-closed condition was characterized by a more regular functional network structure in both groups. The amount of network reorganization due to behavioral state changes was similar in both groups. Consistent findings could be achieved for networks derived from EEG but hardly from MEG recordings, and network construction rules had a rather strong impact on our findings.
Conclusions
Despite the locality of the investigated processes epileptic brain networks differ in their global characteristics from non-epileptic brain networks. Further methodological developments are necessary to improve the characterization of disturbed and normal functional networks.
Significance
An increased regularity and a diminished modulation capability appear characteristic of epileptic brain networks.
A novel scheme for precise diagnostics and effective stabilization of currents in a fuel cell stack
(2010)
Normative Regulations
(2010)
Following the success of PET/CT during the last decade and the recent increasing proliferation of SPECT/CT, another hybrid imaging instrument has been gaining more and more interest: MR-PET. First combined, simultaneous PET and MR studies carried out in small animals demonstrated the feasibility of the new approach. Concurrently, some prototypes of an MR-PET scanner for simultaneous human brain studies have been built, their performance is being tested and preliminary applications have already been shown. Through this pioneering work, it has become clear that advances in the detector design are necessary for further optimization.
Recently, the different issues related to the present state and future prospects of MR-PET were presented and discussed during an international 2-day workshop at the Forschungszentrum Jülich, Germany, held after, and in conjunction with, the 2008 IEEE Nuclear Science Symposium and Medical Imaging Conference in Dresden, Germany on October 27–28, 2008. The topics ranged from small animal MR-PET imaging to human MR-BrainPET imaging, new detector developments, challenges/opportunities for ultra-high field MR-PET imaging and considerations of possible future research and clinical applications. This report presents a critical summary of the contributions made to the workshop.
Differential modulation of valence and arousal in high-alexithymic and low-alexithymic individuals
(2010)
High-alexithymic individuals are characterized by an impaired ability to identify and communicate emotions whereas low-alexithymic individuals have a wide-ranging ability to deal with emotions. This study examined the hypothesis that valence and arousal modifications of emotional stimuli differentially modulate cortical regions in high-alexithymic and low-alexithymic individuals. To this end, 28 high-alexithymic and 25 low-alexithymic individuals were investigated with event-related fMRI using visual emotional stimuli. We found differential neural activations in the dorsal anterior cingulate, the insula and the amygdala. We suggest that these differences may account for the impaired ability of high-alexithymic individuals to appropriately handle emotional stimuli.
Background: One of the most prominent neurobiological models of alexithymia assumes an altered function of the anterior cingulate cortex (ACC) as the crucial neural correlate of alexithymia. So far functional imaging studies have yielded inconclusive results. Therefore, we tested this hypothesis in healthy alexithymics and nonalexithymics in an event-related fMRI study.
Methods: Thirty high- and 30 low-alexithymic right-handed male subjects (selected by the 20-item Toronto Alexithymia Scale, TAS-20) were investigated with event-related fMRI using a picture viewing paradigm. The stimuli consisted of happy, fearful and neutral facial expressions (Ekman-Friesen) as well as positive, negative and neutral pictures from the International Affective Picture System.
Results: Contrasting the high-alexithymic with the low-alexithymic group we observed increased activation of the supragenual ACC for different emotional valences as well as for different emotional stimuli. Moreover, there was a positive correlation of the ACC with the individual TAS-20 scores but no correlations with the individual Beck Depression Inventory scores. Additionally, there was no difference in activity of the amygdala.
Conclusions: We demonstrated that the supragenual ACC is constantly activated more strongly in alexithymic subjects and that this activation is related to the symptoms of alexithymia and not to associated symptoms such as depression. Therefore, our findings support the hypothesis of an altered function of the ACC in alexithymia.
During the development process of a complex technical product, one widely used and important technique is accelerated testing where the applied stress on a component is chosen to exceed the reference stress, i.e. the stress encountered in field operation, in order to reduce the time to failure. For that, the reference stress has to be known. Since a complex technical product may fail regarding numerous failure modes, stress in general is highly dimensional rather than scalar. In addition, customers use their products individually, i.e. field operation should be described by a distribution rather than by one scalar stress value. In this paper, a way to span the customer usage space is shown. It allows the identification of worst case reference stress profiles in significantly reduced dimensions with minimal loss of information. The application example shows that even for a complex product like a combustion engine, stress information can be compressed significantly. With low measurement effort it turned out that only three reference stress cycles were sufficient to cover a broad range of customer stress variety.
Recently, we introduced and mathematically analysed a new method for grid deformation (Grajewski et al., 2009) [15] we call basic deformation method (BDM) here. It generalises the method proposed by Liao et al. (Bochev et al., 1996; Cai et al., 2004; Liao and Anderson, 1992) [4], [6], [20]. In this article, we employ the BDM as core of a new multilevel deformation method (MDM) which leads to vast improvements regarding robustness, accuracy and speed. We achieve this by splitting up the deformation process in a sequence of easier subproblems and by exploiting grid hierarchy. Being of optimal asymptotic complexity, we experience speed-ups up to a factor of 15 in our test cases compared to the BDM. This gives our MDM the potential for tackling large grids and time-dependent problems, where possibly the grid must be dynamically deformed once per time step according to the user's needs. Moreover, we elaborate on implementational aspects, in particular efficient grid searching, which is a key ingredient of the BDM.
The present article describes a standard instrument for the continuous online determination of retinal vessel diameters, the commercially available retinal vessel analyzer. This report is intended to provide informed guidelines for measuring ocular blood flow with this system. The report describes the principles underlying the method and the instruments currently available, and discusses clinical protocol and the specific parameters measured by the system. Unresolved questions and the possible limitations of the technique are also discussed.
High Spatial Resolution 3D MRI of the Larynx Using a Dedicated TX/RX Phased Array Coil at 7.0T
(2010)
MRI holds great potential for elucidating laryngeal and vocal fold anatomy together with the assessment of physiological processes associated in human phonation. However, MRI of human phonation remains very challenging due to the small size of the targeted structures, interfering signal from fat, air between the vocal folds and surrounding muscles and physiological motion. These anatomical/physiological constraints translate into stringent technical requirements in balancing, scan time, image contrast, immunity to physiological motion, temporal resolution and spatial resolution. Motivated by these challenges and limitations this study is aiming at translating the sensitivity gain at ultra-high magnetic fields for enhanced high spatial resolution 3D imaging of the larynx and vocal tract. To approach this goal a dedicated two channel TX/RX larynx coil is being proposed.
Background
To demonstrate the applicability of acoustic cardiac triggering (ACT) for imaging of the heart at ultrahigh magnetic fields (7.0 T) by comparing phonocardiogram, conventional vector electrocardiogram (ECG) and traditional pulse oximetry (POX) triggered 2D CINE acquisitions together with (i) a qualitative image quality analysis, (ii) an assessment of the left ventricular function parameter and (iii) an examination of trigger reliability and trigger detection variance derived from the signal waveforms.
Results
ECG was susceptible to severe distortions at 7.0 T. POX and ACT provided waveforms free of interferences from electromagnetic fields or from magneto-hydrodynamic effects. Frequent R-wave mis-registration occurred in ECG-triggered acquisitions with a failure rate of up to 30% resulting in cardiac motion induced artifacts. ACT and POX triggering produced images free of cardiac motion artefacts. ECG showed a severe jitter in the R-wave detection. POX also showed a trigger jitter of approximately Δt = 72 ms which is equivalent to two cardiac phases. ACT showed a jitter of approximately Δt = 5 ms only. ECG waveforms revealed a standard deviation for the cardiac trigger offset larger than that observed for ACT or POX waveforms.
Image quality assessment showed that ACT substantially improved image quality as compared to ECG (image quality score at end-diastole: ECG = 1.7 ± 0.5, ACT = 2.4 ± 0.5, p = 0.04) while the comparison between ECG vs. POX gated acquisitions showed no significant differences in image quality (image quality score: ECG = 1.7 ± 0.5, POX = 2.0 ± 0.5, p = 0.34).
Conclusions
The applicability of acoustic triggering for cardiac CINE imaging at 7.0 T was demonstrated. ACT's trigger reliability and fidelity are superior to that of ECG and POX. ACT promises to be beneficial for cardiovascular magnetic resonance at ultra-high field strengths including 7.0 T.