Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (1546)
- Fachbereich Wirtschaftswissenschaften (700)
- Fachbereich Elektrotechnik und Informationstechnik (629)
- Fachbereich Energietechnik (598)
- Fachbereich Chemie und Biotechnologie (589)
- INB - Institut für Nano- und Biotechnologien (523)
- Fachbereich Maschinenbau und Mechatronik (472)
- IfB - Institut für Bioengineering (428)
- Fachbereich Luft- und Raumfahrttechnik (368)
- Fachbereich Bauingenieurwesen (327)
Has Fulltext
- no (5531) (remove)
Language
Document Type
- Article (5531) (remove)
Keywords
- avalanche (5)
- Earthquake (4)
- LAPS (4)
- field-effect sensor (4)
- frequency mixing magnetic detection (4)
- CellDrum (3)
- Heparin (3)
- SLM (3)
- additive manufacturing (3)
- capacitive field-effect sensor (3)
The scientific interest for near-Earth asteroids as well as the interest in potentially hazardous asteroids from the perspective of planetary defense led the space community to focus on near-Earth asteroid mission studies. A multiple near-Earth asteroid rendezvous mission with close-up observations of several objects can help to improve the characterization of these asteroids. This work explores the design of a solar-sail spacecraft for such a mission, focusing on the search of possible sequences of encounters and the trajectory optimization. This is done in two sequential steps: a sequence search by means of a simplified trajectory model and a set of heuristic rules based on astrodynamics, and a subsequent optimization phase. A shape-based approach for solar sailing has been developed and is used for the first phase. The effectiveness of the proposed approach is demonstrated through a fully optimized multiple near-Earth asteroid rendezvous mission. The results show that it is possible to visit five near-Earth asteroids within 10 years with near-term solar-sail technology.
Solar Sails for Near- and Medium-Term Scientific Deep Space Missions / W. Sebolt ; B. Dachwald
(2005)
Solar sailcraft of the first generation technology development / Seboldt, Wolfgang ; Dachwald, Bernd
(2003)
Solar Sail Trajectory Optimization for Intercepting, Impacting, and Deflecting Near-Earth Asteroids
(2005)
Solar Sail Kinetic Energy Impactor Trajectory Optimization for an Asteroid-Deflection Mission
(2007)
The cost of solar tower power plants is dominated by the heliostat field making up roughly 50% of investment costs. Classical heliostat design is dominated by mirrors brought into position by steel structures and drives that guarantee high accuracies under wind loads and thermal stress situations. A large fraction of costs is caused by the stiffness requirements of the steel structure, typically resulting in ~ 20 kg/m² steel per mirror area. The typical cost figure of heliostats (figure mentioned by Solucar at Solar Paces Conference, Seville, 2006) is currently in the area of 150 €/m² caused by the increasing price of the necessary raw materials. An interesting option to reduce costs lies in a heliostat design where all moving parts are protected from wind loads. In this way, drives and mechanical layout may be kept less robust, thereby reducing material input and costs. In order to keep the heliostat at an appropriate size, small mirrors (around 10x10 cm²) have to be used, which are placed in a box with a transparent cover. Innovative drive systems are developed in order to obtain a cost-effective design. A 0,5x0,5 m² demonstration unit will be constructed. Tests of the unit are carried out with a high-precision artificial sun unit that imitates the sun’s path with an accuracy of less than 0.5 mrad and creates a beam of parallel light with a divergence of less than 4 mrad.
Soft Materials in Technology and Biology – Characteristics, Properties, and Parameter Identification
(2008)
Socio-technical scenarios for energy-intensive industries: the future of steel production in Germany
(2019)
Smartphone Forensik
(2012)
Slot die coating is applied to deposit thin and homogenous films in roll-to-roll and sheet-to-sheet applications. The critical step in operation is to choose suitable process parameters within the process window. In this work, we investigate an upper limit for stripe coatings. This maximum film thickness is characterized by stripe merging which needs to be avoided in a stable process. It is shown that the upper limit reduces the process window for stripe coatings to a major extent. As a result, stripe coatings at large coating gaps and low viscosities are only possible for relatively thick films. Explaining the upper limit, a theory of balancing the side pressure in the gap region in the cross-web direction has been developed.
Superparamagnetic iron oxide nanoparticles (SPION) are extensively used for magnetic resonance imaging (MRI) and magnetic particle imaging (MPI), as well as for magnetic fluid hyperthermia (MFH). We here describe a sequential centrifugation protocol to obtain SPION with well-defined sizes from a polydisperse SPION starting formulation, synthesized using the routinely employed co-precipitation technique. Transmission electron microscopy, dynamic light scattering and nanoparticle tracking analyses show that the SPION fractions obtained upon size-isolation are well-defined and almost monodisperse. MRI, MPI and MFH analyses demonstrate improved imaging and hyperthermia performance for size-isolated SPION as compared to the polydisperse starting mixture, as well as to commercial and clinically used iron oxide nanoparticle formulations, such as Resovist® and Sinerem®. The size-isolation protocol presented here may help to identify SPION with optimal properties for diagnostic, therapeutic and theranostic applications.
Size unlimited markerless deletions by a transconjugative plasmid-system in Bacillus licheniformis
(2013)
Sisyphus wird Steiff
(2010)
Simultaneous detection of cyanide and heavy metals for environmental analysis by means of µISEs
(2010)
Simultane Atline-Quantifizierung von Magnetpartikeln und Mikroorganismen bei einer HGMS-Filtration
(2015)
Es wird eine neue Atline-Messmethode vorgestellt, mit der während einer Hochgradienten-Magnetseparation (HGMS)-Filtration eine simultane Quantifizierung von Magnetpartikeln und Mikroorganismen im Filtrat vorgenommen werden kann. Dabei gelingt die Quantifizierung signifikant besser als mit bisher verwendeten Messmethoden. Mit dieser Methode ist es möglich, die Trennleistung einer HGMS-Filtration zu bestimmen und einen Filterdurchbruch durch Konzentrationsanstiege im Bereich einiger µg L−1 von Magnetpartikeln im Filtrat frühzeitig zu detektieren, ohne dass nennenswerte Partikelmengen verloren gehen.