Refine
Year of publication
Institute
- Fachbereich Energietechnik (1068) (remove)
Has Fulltext
- no (1068) (remove)
Language
- English (563)
- German (502)
- Multiple languages (1)
- Dutch (1)
- Spanish (1)
Document Type
- Article (594)
- Conference Proceeding (230)
- Book (126)
- Part of a Book (83)
- Doctoral Thesis (10)
- Conference: Meeting Abstract (8)
- Report (7)
- Other (4)
- Talk (2)
- Contribution to a Periodical (1)
Keywords
- Earthquake (5)
- Diversity Management (4)
- Energy storage (4)
- Power plants (4)
- Seismic design (4)
- Associated liquids (3)
- Concentrated solar power (3)
- Hybrid energy system (3)
- INODIS (3)
- Out-of-plane load (3)
Reinforced concrete (RC) structures with masonry infills are widely used for several types of buildings all over the world. However, it is well known that traditional masonry infills constructed with rigid contact to the surrounding RC frame performed rather poor in past earthquakes. Masonry infills showed severe in-plane damages and failed in many cases under out-of-plane seismic loading. As the undesired interactions between frames and infills changes the load transfer on building level, complete collapses of buildings were observed. A possible solution is uncoupling of masonry infills to the frame to reduce the infill contribution activated by the frame deformation under horizontal loading. The paper presents numerical simulations on RC frames equipped with the innovative decoupling system INODIS. The system was developed within the European project INSYSME and allows an effective uncoupling of frame and infill. The simulations are carried out with a micro-modelling approach, which is able to predict the complex nonlinear behaviour resulting from the different materials and their interaction. Each brick is modelled individually and connected taking into account nonlinearity of a brick mortar interface. The calibration of the model is based on small specimen tests and experimental results for one bay one storey frame are used for the validation. The validated model is further used for parametric studies on two storey and two bay infilled frames. The response and change of the structural stiffness are analysed and compared to the traditionally infilled frame. The results confirm the effectiveness of the INODIS system with less damage and relatively low contribution of the infill at high drift levels. In contrast to the uncoupled system configurations, traditionally infilled frames experienced brittle failure at rather low drift levels.
The article presents the investigation of the seismic behaviour of a modern URM building located in the municipality of Finale Emilia in province of Modena, Northern Italy. The building is situated in the centre of the series of the 2012 Northern Italy earthquakes and has not suffered any damage during the earthquake series in 2012. The observed earthquake resistance of the building is compared with predicted resistances based on linear and nonlinear design approaches according to Eurocode. Furthermore, probabilistic analyses based on nonlinear calculation models taking into account scattering of the most relevant input parameters are carried out to identify their influence to the results and to derive fragility curves.
Stahlbetonrahmentragwerke mit Mauerwerksausfachungen weisen nach Erdbebenereignissen häufig schwere Schäden auf, da die Ausfachungen ohne weitere konstruktive Maßnahmen mit vollem Kontakt zum Stahlbetonrahmen eingemauert werden. Durch die unplanmäßige Beteiligung am horizontalen Lastabtrag erfahren die Ausfachungen Belastungen in Wandebene und beeinflussen das globale Schwingungsverhalten der Rahmentragwerke. In Kombination mit den gleichzeitig auftretenden seismischen Trägheitskräften senkrecht zur Wand führt dies in vielen Fällen zu einem Versagen der mit niedrigen Festigkeiten ausgeführten Ausfachungen. Dies war der Anlass in dem europäischen Forschungsprojekt INSYSME ein Entkopplungssystem zu entwickeln, mit dem Rahmen und Ausfachung durch ein spezielles Profil aus Elastomeren entkoppelt werden.
Das Profil ermöglicht Relativverschiebungen zwischen Rahmen und Ausfachung und stellt gleichzeitig die Aufnahme von Belastungen senkrecht zur Wand sicher. Der Beitrag erläutert zunächst den Aufbau des Systems und gibt einen Überblick über die in Kleinbauteilversuchen ermittelten Tragfähigkeiten. Zudem werden experimentelle Untersuchungen an mit hochwärmedämmenden Mauerziegeln ausgefachten Stahlbetonrahmen mit und ohne Entkopplungssystem für getrennte und kombinierte Belastungen in und senkrecht zur Wandebene vorgestellt. Auf Grundlage einer Versuchsauswertung und eines Ergebnisvergleichs werden Wirkungsweise und Effektivität des entwickelten Entkopplungssystems demonstriert.
In recent years, many onshore wind turbines are erected in seismic active regions and on soils with poor load bearing capacity, where pile grids are inevitable to transfer the loads into the ground. In this contribution, a realistic multi pile grid is designed to analyze the dynamics of a wind turbine tower including frequency dependent soil-structure-interaction. It turns out that different foundations on varying soil configurations heavily influence the vibration response. While the vibration amplitude is mostly attenuated, certain unfavorable combinations of structure and soil parameters lead to amplification in the range of the system's natural frequencies. This testifies the need for overall dynamic analysis in the assessment of the dynamic stability and the holistic frequency tuning of the turbines.
The behaviour of infilled reinforced concrete frames under horizontal load has been widely investigated, both experimentally and numerically. Since experimental tests represent large investments, numerical simulations offer an efficient approach for a more comprehensive analysis. When RC frames with masonry infill walls are subjected to horizontal loading, their behaviour is highly non-linear after a certain limit, which makes their analysis quite difficult. The non-linear behaviour results from the complex inelastic material properties of the concrete, infill wall and conditions at the wall-frame interface. In order to investigate this non-linear behaviour in detail, a finite element model using a micro modelling approach is developed, which is able to predict the complex non-linear behaviour resulting from the different materials and their interaction. Concrete and bricks are represented by a non-linear material model, while each reinforcement bar is represented as an individual part installed in the concrete part and behaving elasto-plastically. Each brick is modelled individually and connected taking into account the non-linearity of a brick mortar interface. The same approach is followed using two finite element software packages and the results are compared with the experimental results. The numerical models show a good agreement with the experiments in predicting the overall behaviour, but also very good matching for strength capacity and drift. The results emphasize the quality and the valuable contribution of the numerical models for use in parametric studies, which are needed for the derivation of design recommendations for infilled frame structures.
Eine seismische Anregung verursacht in einem Flüssigkeitstank einen kombinierten Spannungszustand, was zu einem Stabilitätsversagen der häufig sehr dünnwandigen Konstruktionen führen kann. Für die Durchführung von Stabilitätsnachweisen stehen verschiedene Verfahren zur Verfügung. Üblicherweise werden aus Gründen der Einfachheit spannungsbasierte Verfahren angewendet. Diese sind für Einheitslastfälle experimentell abgesichert, wobei eine Übertragung auf kombinierte Spannungszustände wie im Erdbebenfall nur begrenzt möglich ist. Alternativ kann ein globales, numerisches Konzept, das LBA/MNA-Verfahren, angewendet werden. Das Verfahren kombiniert eine materiell nichtlineare Berechnung (MNA) mit einer linearen Beulanalyse (LBA) und erfasst die Interaktion verschiedener gleichzeitig auftretender Beanspruchungen implizit im Nachweis. Dieser Beitrag demonstriert die Anwendung der Verfahren am Beispiel verschiedener Tankgeometrien mit Höhe/Radius-Verhältnissen zwischen 1 ≤ H/R ≤ 2 und Radius/Tankwand-Verhältnissen zwischen 500 ≤ R/t ≤ 1000 und diskutiert zusätzlich die Defizite der spannungsbasierten Nachweisverfahren.
Die erdbebensichere Auslegung von erdverlegten Rohrleitungssystemen ist von wesentlicher Bedeutung zur Sicherstellung der Funktionalität der Versorgungsinfrastruktur nach einem Erdbebenereignis. Zur Vermeidung von Netzausfällen ist es erforderlich, die räumlich weit ausgedehnten Leitungssysteme mit geeigneten rechnerischen Modellen seismisch zu bemessen. Der vorliegende Beitrag behandelt die Beanspruchung von Rohrleitungssystemen durch seismische Welleneinwirkung und stellt geeignete Näherungsansätze und ein detailliertes Rechenmodell für seismische Leitungsanalysen vor. Mit den Ansätzen wird in Berechnungsbeispielen der Einfluss wesentlicher Parameter auf die seismisch induzierten Dehnungen in Rohrleitungssystemen untersucht.
The 2012 Emilia-Romagna earthquake, that mainly struck the homonymous Italian region provoking 28 casualties and damage to thousands of structures and infrastructures, is an exceptional source of information to question, investigate, and challenge the validity of seismic fragility functions and loss curves from an empirical standpoint. Among the most recent seismic events taking place in Europe, that of Emilia-Romagna is quite likely one of the best documented, not only in terms of experienced damages, but also for what concerns occurred losses and necessary reconstruction costs. In fact, in order to manage the compensations in a fair way both to citizens and business owners, soon after the seismic sequence, the regional administrative authority started (1) collecting damage and consequence-related data, (2) evaluating information sources and (3) taking care of the cross-checking of various reports. A specific database—so-called Sistema Informativo Gestione Europa (SFINGE)—was devoted to damaged business activities. As a result, 7 years after the seismic events, scientists can rely on a one-of-a-kind, vast and consistent database, containing information about (among other things): (1) buildings’ location and dimensions, (2) occurred structural damages, (3) experienced direct economic losses and (4) related reconstruction costs. The present work is focused on a specific data subset of SFINGE, whose elements are Long-Span-Beam buildings (mostly precast) deployed for business activities in industry, trade or agriculture. With the available set of data, empirical fragility functions, cost and loss ratio curves are elaborated, that may be included within existing Performance Based Earthquake Engineering assessment toolkits.
Stahlbetonrahmentragwerke mit Ausfachungen aus Mauerwerk weisen nach Erdbeben häufig schwere Schäden auf. Gründe hierfür sind die Beanspruchungen der Ausfachungswände durch die aufgezwungenen Rahmenverformungen in Wandebene und die gleichzeitig auftretenden Trägheitskräfte senkrecht zur Wandebene in Kombination mit der konstruktiven Ausführung des Ausfachungsmauerwerks. Die Ausfachung wird in der Regel knirsch gegen die Rahmenstützen gemauert, wobei der Verschluss der oberen Fuge mit Mörtel oder Montageschaum erfolgt. Dadurch kommt es im Erdbebenfall zu lokalen Interaktionen zwischen Ausfachung und Rahmen, die in der Folge zu einem Versagen einzelner Ausfachungswände oder zu einem sukzessiven Versagen des Gesamtgebäudes führen können. Die beobachteten Schäden waren die Motivation dafür, in dem europäischen Forschungsprojekt INSYSME für Stahlbetonrahmentragwerke mit Ausfachungen aus hochwärmedämmenden Ziegelmauerwerk innovative Lösungen zur Verbesserung des seismischen Verhaltens zu entwickeln. Der vorliegende Beitrag stellt die im Rahmen des Projekts von den deutschen Projektpartnern (Universität Kassel, SDA-engineering GmbH) entwickelten Lösungen vor und vergleicht deren seismisches Verhalten mit der traditionellen Ausführung der Ausfachungswände. Grundlage für den Vergleich sind statisch-zyklische Wandversuche und Simulationen auf Wandebene. Aus den Ergebnissen werden Empfehlungen für die erdbebensichere Auslegung von Stahlbetonrahmentragwerken mit Ausfachungen aus Ziegelmauerwerk abgeleitet.
Mit finanzieller Unterstützung der Deutschen Gesellschaft für Mauerwerks- und Wohnungsbau e.V. (DGfM) und des Deutschen Instituts für Bautechnik in Berlin (DIBt) wurden zwei aufeinander aufbauende Forschungsvorhaben zur Verbesserung der seismischen Nachweise von Mauerwerksbauten in deutschen Erdbebengebieten durchgeführt. Zunächst wurde das seismische Verhalten von drei modernen unbewehrten Mauerwerksgebäuden in der Region Emilia Romagna in Italien während der Erdbebenserie im Jahr 2012 in Kooperation mit der Universität Pavia eingehend untersucht. Aufbauend auf den Erkenntnissen dieser Untersuchungen wurde ein verbessertes seismisches Bemessungskonzept für unbewehrte Mauerwerksbauten erarbeitet. Der Beitrag stellt die wesentlichen Ergebnisse dieser Forschungsarbeiten und deren Eingang in die Normung vor.
Erdbebennachweis von Mauerwerksbauten mit realistischen Modellen und erhöhten Verhaltensbeiwerten
(2020)
Die Anwendung des linearen Nachweiskonzepts auf Mauerwerksbauten führt dazu, dass bereits heute Standsicherheitsnachweise für Gebäude mit üblichen Grundrissen in Gebieten mit moderaten Erdbebeneinwirkungen nicht mehr geführt werden können. Diese Problematik wird sich in Deutschland mit der Einführung kontinuierlicher probabilistischer Erdbebenkarten weiter verschärfen. Aufgrund der Erhöhung der seismischen Einwirkungen, die sich vielerorts ergibt, ist es erforderlich, die vorhandenen, bislang nicht berücksichtigten Tragfähigkeitsreserven in nachvollziehbaren Nachweiskonzepten in der Baupraxis verfügbar zu machen. Der vorliegende Beitrag stellt ein Konzept für die gebäudespezifische Ermittlung von erhöhten Verhaltensbeiwerten vor. Die Verhaltensbeiwerte setzen sich aus drei Anteilen zusammen, mit denen die Lastumverteilung im Grundriss, die Verformungsfähigkeit und Energiedissipation sowie die Überfestigkeiten berücksichtigt werden. Für die rechnerische Ermittlung dieser drei Anteile wird ein nichtlineares Nachweiskonzept auf Grundlage von Pushover-Analysen vorgeschlagen, in denen die Interaktionen von Wänden und Geschossdecken durch einen Einspanngrad beschrieben werden. Für die Bestimmung der Einspanngrade wird ein nichtlinearer Modellierungsansatz eingeführt, mit dem die Interaktion von Wänden und Decken abgebildet werden kann. Die Anwendung des Konzepts mit erhöhten gebäudespezifischen Verhaltensbeiwerten wird am Beispiel eines Mehrfamilienhauses aus Kalksandsteinen demonstriert. Die Ergebnisse der linearen Nachweise mit erhöhten Verhaltensbeiwerten für dieses Gebäude liegen deutlich näher an den Ergebnissen nichtlinearer Nachweise und somit bleiben übliche Grundrisse in Erdbebengebieten mit den traditionellen linearen Rechenansätzen nachweisbar.
In collaborative research projects, both researchers and practitioners work together solving business-critical challenges. These projects often deal with ETL processes, in which humans extract information from non-machine-readable documents by hand. AI-based machine learning models can help to solve this problem.
Since machine learning approaches are not deterministic, their quality of output may decrease over time. This fact leads to an overall quality loss of the application which embeds machine learning models. Hence, the software qualities in development and production may differ.
Machine learning models are black boxes. That makes practitioners skeptical and increases the inhibition threshold for early productive use of research prototypes. Continuous monitoring of software quality in production offers an early response capability on quality loss and encourages the use of machine learning approaches. Furthermore, experts have to ensure that they integrate possible new inputs into the model training as quickly as possible.
In this paper, we introduce an architecture pattern with a reference implementation that extends the concept of Metrics Driven Research Collaboration with an automated software quality monitoring in productive use and a possibility to auto-generate new test data coming from processed documents in production.
Through automated monitoring of the software quality and auto-generated test data, this approach ensures that the software quality meets and keeps requested thresholds in productive use, even during further continuous deployment and changing input data.
Stored and cooled, highly-charged ions offer unprecedented capabilities for precision studies in the realm of atomic, nuclear structure and astrophysics[1]. After the successful investigation of the 96Ru(p,7)97Rh reaction cross section in 2009[2], the first measurement of the 124Xe(p,7)125Cs reaction cross section has been performed with decelerated, fully-ionized 124Xe ions in 2016 at the Experimental Storage Ring (ESR) of GSI[3]. Using a Double Sided Silicon Strip Detector, introduced directly into the ultra-high vacuum environment of a storage ring, the 125Cs proton-capture products have been successfully detected. The cross section has been measured at 5 different energies between 5.5AMeV and 8AMeV, on the high energy tail of the Gamow-window for hot, explosive scenarios such as supernovae and X-ray binaries. The elastic scattering on the H2 gas jet target is the major source of background to count the (p,7) events. Monte Carlo simulations show that an additional slit system in the ESR in combination with the energy information of the Si detector will enable background free measurements of the proton-capture products. The corresponding hardware is being prepared and will increase the sensitivity of the method tremendously.
Cross sections for neutron-induced reactions of short-lived nuclei are essential for nuclear astrophysics since these reactions in the stars are responsible for the production of most heavy elements in the universe. These reactions are also key in applied domains like energy production and medicine. Nevertheless, neutron-induced cross-section measurements can be extremely challenging or even impossible to perform due to the radioactivity of the targets involved. Indirect measurements through the surrogate-reaction method can help to overcome these difficulties.
The surrogate-reaction method relies on the use of an alternative reaction that will lead to the formation of the same excited nucleus as in the neutron-induced reaction of interest. The decay probabilities (for fission, neutron and gamma-ray emission) of the nucleus produced via the surrogate reaction allow one to constrain models and the prediction of the desired neutron cross sections.
We propose to perform surrogate reaction measurements in inverse kinematics at heavy-ion storage rings, in particular at the CRYRING@ESR of the GSI/FAIR facility. We present the conceptual idea of the most promising setup to measure for the first time simultaneously the fission, neutron and gamma-ray emission probabilities. The results of the first simulations considering the 238U(d,d') reaction are shown, as well as new technical developments that are being carried out towards this set-up.
The chapter initially provides a summary of the contents of Eurocode 8, its aim being to offer both to the students and to practising engineers an easy introduction into the calculation and dimensioning procedures of this earthquake code. Specifically, the general rules for earthquake-resistant structures, the definition of design response spectra taking behaviour and importance factors into account, the application of linear and non-linear calculation methods and the structural safety verifications at the serviceability and ultimate limit state are presented. The application of linear and non-linear calculation methods and corresponding seismic design rules is demonstrated on practical examples for reinforced concrete, steel and masonry buildings. Furthermore, the seismic assessment of existing buildings is discussed and illustrated on the example of a typical historical masonry building in Italy. The examples are worked out in detail and each step of the design process, from the preliminary analysis to the final design, is explained in detail.
Industrial units consist of the primary load-carrying structure and various process engineering components, the latter being by far the most important in financial terms. In addition, supply structures such as free-standing tanks and silos are usually required for each plant to ensure the supply of material and product storage. Thus, for the earthquake-proof design of industrial plants, design and construction rules are required for the primary structures, the secondary structures and the supply structures. Within the framework of these rules, possible interactions of primary and secondary structures must also be taken into account. Importance factors are used in seismic design in order to take into account the usually higher risk potential of an industrial unit compared to conventional building structures. Industrial facilities must be able to withstand seismic actions because of possibly wide-ranging damage consequences in addition to losses due to production standstill and the destruction of valuable equipment. The chapter presents an integrated concept for the seismic design of industrial units based on current seismic standards and the latest research results. Special attention is devoted to the seismic design of steel thin-walled silos and tank structures.
The fundamental modeling of energy systems through individual unit commitment decisions is crucial for energy system planning. However, current large-scale models are not capable of including uncertainties or even risk-averse behavior arising from forecasting errors of variable renewable energies. However, risks associated with uncertain forecasting errors have become increasingly relevant within the process of decarbonization. The intraday market serves to compensate for these forecasting errors. Thus, the uncertainty of forecasting errors results in uncertain intraday prices and quantities. Therefore, this paper proposes a two-stage risk-constrained stochastic optimization approach to fundamentally model unit commitment decisions facing an uncertain intraday market. By the nesting of Lagrangian relaxation and an extended Benders decomposition, this model can be applied to large-scale, e.g., pan-European, power systems. The approach is applied to scenarios for 2023—considering a full nuclear phase-out in Germany—and 2035—considering a full coal phase-out in Germany. First, the influence of the risk factors is evaluated. Furthermore, an evaluation of the market prices shows an increase in price levels as well as an increasing day-ahead-intraday spread in 2023 and in 2035. Finally, it is shown that intraday cross-border trading has a significant influence on trading volumes and prices and ensures a more efficient allocation of resources.
SHEMAT-Suite: An open-source code for simulating flow, heat and species transport in porous media
(2020)
SHEMAT-Suite is a finite-difference open-source code for simulating coupled flow, heat and species transport in porous media. The code, written in Fortran-95, originates from geoscientific research in the fields of geothermics and hydrogeology. It comprises: (1) a versatile handling of input and output, (2) a modular framework for subsurface parameter modeling, (3) a multi-level OpenMP parallelization, (4) parameter estimation and data assimilation by stochastic approaches (Monte Carlo, Ensemble Kalman filter) and by deterministic Bayesian approaches based on automatic differentiation for calculating exact (truncation error-free) derivatives of the forward code.
Innovative breeds of sugar cane yield up to 2.5 times as much organic matter as conventional breeds, resulting in a great potential for biogas production. The use of biogas production as a complementary solution to conventional and second-generation ethanol production in Brazil may increase the energy produced per hectare in the sugarcane sector. Herein, it was demonstrated that through ensiling, energy cane can be conserved for six months; the stored cane can then be fed into a continuous biogas process. This approach is necessary to achieve year-round biogas production at an industrial scale. Batch tests revealed specific biogas potentials between 400 and 600 LN/kgVS for both the ensiled and non-ensiled energy cane, and the specific biogas potential of a continuous biogas process fed with ensiled energy cane was in the same range. Peak biogas losses through ensiling of up to 27% after six months were observed. Finally, compared with second-generation ethanol production using energy cane, the results indicated that biogas production from energy cane may lead to higher energy yields per hectare, with an average energy yield of up to 162 MWh/ha. Finally, the Farm²CBG concept is introduced, showing an approach for decentralized biogas production.
Large scale central receiver systems typically deploy between thousands to more than a hundred thousand heliostats. During solar operation, each heliostat is aligned individually in such a way that the overall surface normal bisects the angle between the sun’s position and the aim point coordinate on the receiver. Due to various tracking error sources, achieving accurate alignment ≤1 mrad for all the heliostats with respect to the aim points on the receiver without a calibration system can be regarded as unrealistic. Therefore, a calibration system is necessary not only to improve the aiming accuracy for achieving desired flux distributions but also to reduce or eliminate spillage. An overview of current larger-scale central receiver systems (CRS), tracking error sources and the basic requirements of an ideal calibration system is presented. Leading up to the main topic, a description of general and specific terms on the topics heliostat calibration and tracking control clarifies the terminology used in this work. Various figures illustrate the signal flows along various typical components as well as the corresponding monitoring or measuring devices that indicate or measure along the signal (or effect) chain. The numerous calibration systems are described in detail and classified in groups. Two tables allow the juxtaposition of the calibration methods for a better comparison. In an assessment, the advantages and disadvantages of individual calibration methods are presented.
In this paper, a coupled multiphase model considering both non-linearities of water retention curves and solid state modeling is proposed. The solid displacements and the pressures of both water and air phases are unknowns of the proposed model. The finite element method is used to solve the governing differential equations. The proposed method is demonstrated through simulation of seepage test and partially consolidation problem. Then, implementation of the model is done by using hypoplasticity for the solid phase and analyzing the fully saturated triaxial experiments. In integration of the constitutive law error controlling is improved and comparisons done accordingly. In this work, the advantages and limitations of the numerical model are discussed.
A German–Brazilian research project investigates sugarcane as an energy plant in anaerobic digestion for biogas production. The aim of the project is a continuous, efficient, and stable biogas process with sugarcane as the substrate. Tests are carried out in a fermenter with a volume of 10 l.
In order to optimize the space–time load to achieve a stable process, a continuous process in laboratory scale has been devised. The daily feed in quantity and the harvest time of the substrate sugarcane has been varied. Analyses of the digester content were conducted twice per week to monitor the process: The ratio of inorganic carbon content to volatile organic acid content (VFA/TAC), the concentration of short-chain fatty acids, the organic dry matter, the pH value, and the total nitrogen, phosphate, and ammonium concentrations were monitored. In addition, the gas quality (the percentages of CO₂, CH₄, and H₂) and the quantity of the produced gas were analyzed.
The investigations have exhibited feasible and economical production of biogas in a continuous process with energy cane as substrate. With a daily feeding rate of 1.68gᵥₛ/l*d the average specific gas formation rate was 0.5 m3/kgᵥₛ. The long-term study demonstrates a surprisingly fast metabolism of short-chain fatty acids. This indicates a stable and less susceptible process compared to other substrates.
In many cities, diesel buses are being replaced by electric buses with the aim of reducing local emissions and thus improving air quality. The protection of the environment and the health of the population is the highest priority of our society. For the transport companies that operate these buses, not only ecological issues but also economic issues are of great importance. Due to the high purchase costs of electric buses compared to conventional buses, operators are forced to use electric vehicles in a targeted manner in order to ensure amortization over the service life of the vehicles. A compromise between ecology and economy must be found in order to both protect the environment and ensure economical operation of the buses.
In this study, we present a new methodology for optimizing the vehicles’ charging time as a function of the parameters CO₂eq emissions and electricity costs. Based on recorded driving profiles in daily bus operation, the energy demands of conventional and electric buses are calculated for the passenger transportation in the city of Aachen in 2017. Different charging scenarios are defined to analyze the influence of the temporal variability of CO₂eq intensity and electricity price on the environmental impact and economy of the bus. For every individual day of a year, charging periods with the lowest and highest costs and emissions are identified and recommendations for daily bus operation are made. To enable both the ecological and economical operation of the bus, the parameters of electricity price and CO₂ are weighted differently, and several charging periods are proposed, taking into account the priorities previously set. A sensitivity analysis is carried out to evaluate the influence of selected parameters and to derive recommendations for improving the ecological and economic balance of the battery-powered electric vehicle.
In all scenarios, the optimization of the charging period results in energy cost savings of a maximum of 13.6% compared to charging at a fixed electricity price. The savings potential of CO₂eq emissions is similar, at 14.9%. From an economic point of view, charging between 2 a.m. and 4 a.m. results in the lowest energy costs on average. The CO₂eq intensity is also low in this period, but midday charging leads to the largest savings in CO₂eq emissions. From a life cycle perspective, the electric bus is not economically competitive with the conventional bus. However, from an ecological point of view, the electric bus saves on average 37.5% CO₂eq emissions over its service life compared to the diesel bus. The reduction potential is maximized if the electric vehicle exclusively consumes electricity from solar and wind power.
Speicher statt Kohle. Integration thermischer Stromspeicher in vorhandene Kraftwerksstandorte
(2019)
Die Energiewirtschaft befindet sich in einem starken Wandel, der v. a. durch die Energiewende und Digitalisierung Druck auf sämtliche Marktteilnehmer ausübt. Das klassische Geschäftsmodell des Energieversorgungsunternehmens verändert sich dabei grundlegend. Der kontinuierlich ansteigende Einsatz dezentraler und volatiler Erzeugungsanlagen macht die Identifikation von Flexibilitätspotenzialen notwendig, um weiterhin eine hohe Versorgungssicherheit zu gewährleisten. Dieser Schritt ist nur mit einem hohen Digitalisierungsgrad möglich. Eine funktionale Plattform mit Microservices, die zu Geschäftsprozessen verbunden werden können, wird als Möglichkeit zur Aktivierung der Flexibilität und Digitalisierung der Energieversorgungsunternehmen im Folgenden vorgestellt.
Extrem hohe Blitzströme
(2018)
Blitze sind nach wie vor eine enorme Schadensquelle für Personenschäden, Brände, mechanische Zerstörungen und insbesondere auch Überspannungen. Das zeigen nicht zuletzt aktuelle Statistiken der Schadensversicherer. Immer wieder gibt es Meldungen über extrem hohe Blitzströme, die natürlich auch zu großen Schäden und Zerstörungen führen können. Dabei werden Scheitelwerte von teilweise deutlich über 300 kA genannt. Dies wirft Fragen auf, da die „klassische“ Blitzstatistik (z. B. nach CIGRE und IEC [8][10]) bisher solche Werte nicht kennt. Diese extremen Blitzströme werden meist aus den Daten von Blitzortungssystemen ermittelt.
Extrem hohe Blitzströme
(2017)