Refine
Year of publication
- 2013 (174) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (54)
- INB - Institut für Nano- und Biotechnologien (35)
- Fachbereich Elektrotechnik und Informationstechnik (29)
- Fachbereich Chemie und Biotechnologie (26)
- IfB - Institut für Bioengineering (24)
- Fachbereich Energietechnik (16)
- Fachbereich Luft- und Raumfahrttechnik (14)
- Fachbereich Wirtschaftswissenschaften (12)
- Fachbereich Bauingenieurwesen (9)
- Fachbereich Maschinenbau und Mechatronik (6)
Language
- English (174) (remove)
Document Type
- Article (97)
- Conference Proceeding (57)
- Part of a Book (7)
- Doctoral Thesis (4)
- Book (2)
- Other (2)
- Patent (2)
- Report (2)
- Conference: Meeting Abstract (1)
Keywords
- industrial research (2)
- metal structure (2)
- steel (2)
- Bacillus atrophaeus (1)
- Business Models (1)
- Epithel (1)
- Fibroblast (1)
- IT Products (1)
- Product Management (1)
- Strategic Business Planning (1)
A High-Throughput Functional Complementation Assay for Classification of BRCA1 Missense Variants
(2013)
Obesity-induced overexpression of miR-802 impairs glucose metabolism through silencing of Hnf1b
(2013)
The network approach towards the analysis of the dynamics of complex systems has been successfully applied in a multitude of studies in the neurosciences and has yielded fascinating insights. With this approach, a complex system is considered to be composed of different constituents which interact with each other. Interaction structures can be compactly represented in interaction networks. In this contribution, we present a brief overview about how interaction networks are derived from multivariate time series, about basic network characteristics, and about challenges associated with this analysis approach.
Size unlimited markerless deletions by a transconjugative plasmid-system in Bacillus licheniformis
(2013)
A methodology for assessment, seismic verification and strengthening of existing masonry buildings is presented in this paper. The verification is performed using a calculation model calibrated with the results from ambient vibration measurements. The calibrated model serves as an input for a deformation-based verification procedure based on the Capacity Spectrum Method (CSM). The bearing capacity of the building is calculated from experimental capacity curves of the individual walls idealized with bilinear elastic-perfectly plastic curves. The experimental capacity curves were obtained from in-plane cyclic loading tests on unreinforced and strengthened masonry walls with reinforced concrete jackets. The seismic action is compared with the load-bearing capacity of the building considering non-linear material behavior with its post-peak capacity. The application of the CSM to masonry buildings and the influence of a traditional strengthening method are demonstrated on the example of a public school building in Skopje, Macedonia.
Robust addresses the renovation and improvement of existing residential, industrial and commercial buildings using steel-based technologies, focusing on techniques such as over-cladding, over-roofing and roof-top extensions. Steel-intensive renovation techniques currently on the market were reviewed. Performance criteria were developed for over-cladding systems meeting current regulatory standards, with guidelines on how to achieve appropriate levels of air-tightness.
The carbonized rice husk (CRH) was evaluated for its wound healing activity in rats using excision models. In this study, the influences of CRH on wound healing in rat skin in vivo and cellular behavior of human dermal fibroblasts in vitro were investigated. The obtained results showed that the CRH treatment promoted wound epithelization in rats and exhibited moderate inhibition of cell proliferation in vitro. CRH with lanolin oil treated wounds were found to epithelize faster as compared to controls.
Seismic excited liquid filled tanks are subjected to extreme loading due to hydrodynamic pressures, which can lead to nonlinear stability failure of the thinwalled cylindrical tanks, as it is known from past earthquakes. A significant reduction of the seismically induced loads can be obtained by the application of base isolation systems, which have to be designed carefully with respect to the modified hydrodynamic behaviour of the tank in interaction with the liquid. For this reason a highly sophisticated fluid-structure interaction model has to be applied for a realistic simulation of the overall dynamic system. In the following, such a model is presented and compared with the results of simplified mathematical models for rigidly supported tanks. Finally, it is examined to what extent a simple mechanical model can represent the behaviour of a base isolated tank in case of seismic excitation