Refine
Year of publication
- 2022 (91) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (34)
- IfB - Institut für Bioengineering (22)
- Fachbereich Chemie und Biotechnologie (14)
- INB - Institut für Nano- und Biotechnologien (13)
- Fachbereich Energietechnik (10)
- ECSM European Center for Sustainable Mobility (6)
- Fachbereich Bauingenieurwesen (6)
- Fachbereich Luft- und Raumfahrttechnik (6)
- Fachbereich Wirtschaftswissenschaften (6)
- Fachbereich Elektrotechnik und Informationstechnik (5)
Document Type
- Article (91) (remove)
Keywords
- Chemometrics (2)
- Earthquake (2)
- Heparin (2)
- NMR spectroscopy (2)
- biosensors (2)
- damage (2)
- Actuator disk modelling (1)
- Algal Turf Scrubber (1)
- Algal–bacterial bioflm (1)
- Alkalihalobacillus okhensis (1)
Although several successful applications of benchtop nuclear magnetic resonance (NMR) spectroscopy in quantitative mixture analysis exist, the possibility of calibration transfer remains mostly unexplored, especially between high- and low-field NMR. This study investigates for the first time the calibration transfer of partial least squares regressions [weight average molecular weight (Mw) of lignin] between high-field (600 MHz) NMR and benchtop NMR devices (43 and 60 MHz). For the transfer, piecewise direct standardization, calibration transfer based on canonical correlation analysis, and transfer via the extreme learning machine auto-encoder method are employed. Despite the immense resolution difference between high-field and low-field NMR instruments, the results demonstrate that the calibration transfer from high- to low-field is feasible in the case of a physical property, namely, the molecular weight, achieving validation errors close to the original calibration (down to only 1.2 times higher root mean square errors). These results introduce new perspectives for applications of benchtop NMR, in which existing calibrations from expensive high-field instruments can be transferred to cheaper benchtop instruments to economize.
This work introduces a novel method for the detection of H₂O₂ vapor/aerosol of low concentrations, which is mainly applied in the sterilization of equipment in medical industry. Interdigitated electrode (IDE) structures have been fabricated by means of microfabrication techniques. A differential setup of IDEs was prepared, containing an active sensor element (active IDE) and a passive sensor element (passive IDE), where the former was immobilized with an enzymatic membrane of horseradish peroxidase that is selective towards H₂O₂. Changes in the IDEs’ capacitance values (active sensor element versus passive sensor element) under H₂O₂ vapor/aerosol atmosphere proved the detection in the concentration range up to 630 ppm with a fast response time (<60 s). The influence of relative humidity was also tested with regard to the sensor signal, showing no cross-sensitivity. The repeatability assessment of the IDE biosensors confirmed their stable capacitive signal in eight subsequent cycles of exposure to H₂O₂ vapor/aerosol. Room-temperature detection of H₂O₂ vapor/aerosol with such miniaturized biosensors will allow a future three-dimensional, flexible mapping of aseptic chambers and help to evaluate sterilization assurance in medical industry.