Refine
Year of publication
Institute
- Fachbereich Bauingenieurwesen (47) (remove)
Has Fulltext
- yes (47) (remove)
Document Type
- Conference Proceeding (36)
- Article (6)
- Course Material (2)
- Report (2)
- Book (1)
Keywords
- Kanalisation (4)
- Aachen / Fachhochschule Aachen / Fachbereich Bauingenieurwesen (3)
- Absolvententreffen (3)
- Alfha.net (3)
- Alumni (3)
- Fließgewässer (3)
- Geodatenbank (3)
- Geodatenhaltung (3)
- Geoinformationen (3)
- Geoinformationssystem (3)
Zugriffsart
- weltweit (4)
Is part of the Bibliography
- no (47)
Dipl.Ing. Johann Andorfer , Tandler.com GmbH, Buch a. Erlbach. Abstract zum 1. Aachener Softwaretag in der Wasserwirtschaft <1,2007, Aachen>. 2 S. (S. 136-137) Eine nachhaltige Sicherung der Funktionalität und der ökologischen Verträglichkeit eines mittleren bis großen Kanalnetzes erfordert eine umfassende und detaillierte Modellierung in Raum und Zeit. Um den in den Richtlinien geforderten statistischen Anforderungen gerecht zu werden und die jährlichen Häufigkeiten, Mengen und Zeiträume der Belastungen erwartungstreu abschätzen zu können, ist es zielführend und notwendig, lange Zeiträume und die Gesamtheit der Einzugsgebiete möglichst detailliert zu betrachten. Die hydraulische Funktionalität und Sicherheit soll meistens mit Hilfe zeitsymmetrischer (hydrodynamischer) Verfahren nur durch Betrachtung von Modellregen, allenfalls Regenserien, sichergestellt werden. Für die Abschätzung der jährlich zu erwartenden Emissionen in unsere natürlichen Gewässer mit ihren Mengen, Frequenzen und Dauern werden normalerweise Langzeitsimulationen natürlicher Regenreihen über möglichst große Zeiträume mit zeitasymmetrischen (hydrologischen) Verfahren durchgeführt. Die betrachteten Kanalnetze werden zumeist vereinfacht (Grobnetze), um die Rechenzeiten erträglicher zu gestalten. Wünschenswert wäre jedoch eine allen Anforderungen gerecht werdende wirklichkeitsnahe Modellierung des gesamten Kanalnetzes in all seinen Details, Vermaschungen und Wechselwirkungen (Feinnetz) und dessen zeitsymmetrische und damit verlässliche Simulation mit langjährigen Regenreihen. Bereits vor 15 Jahren wurde im Hause Tandler begonnen, die Berechnungssoftware durch Parallelisierung auf symmetrische Multiprozessortechnologien auszurichten. In neuerer Zeit hält diese Technik durch die Mehrkernprozessoren in normalen Notebooks und PCs Einzug in die Ingenieurbüros und Abwasserbetriebe und sorgt schon für wesentliche Einsparungen an Rechenzeit. Doch erst durch die Kombination der Parallelisierung mit dem Prinzip des verteilten Rechnens (d.h. die Einbeziehung mehrerer PCs eines Netzwerkes in die Berechnung) erhält man die Chance ausreichend Rechenkapazität zur Verfügung zu stellen, um nicht nur eine einzelne Langzeitsimulation eines Feinnetzes durchzuführen, sondern sogar mehrere Sanierungsalternativen zu überprüfen. Die zukunftsweisenden Arbeiten von Dipl. Math. R. Tandler auf diesem Gebiet sind Thema dieses Vortrags.
Previous studies optimized the dimensions of coaxial heat exchangers using constant mass fow rates as a boundary condition. They show a thermal optimal circular ring width of nearly zero. Hydraulically optimal is an inner to outer pipe radius ratio of 0.65 for turbulent and 0.68 for laminar fow types. In contrast, in this study, fow conditions in the circular ring are kept constant (a set of fxed Reynolds numbers) during optimization. This approach ensures fxed fow conditions and prevents inappropriately high or low mass fow rates. The optimization is carried out for three objectives: Maximum energy gain, minimum hydraulic efort and eventually optimum net-exergy balance. The optimization changes the inner pipe radius and mass fow rate but not the Reynolds number of the circular ring. The thermal calculations base on Hellström’s borehole resistance and the hydraulic optimization on individually calculated linear loss of head coefcients. Increasing the inner pipe radius results in decreased hydraulic losses in the inner pipe but increased losses in the circular ring. The net-exergy diference is a key performance indicator and combines thermal and hydraulic calculations. It is the difference between thermal exergy fux and hydraulic efort. The Reynolds number in the circular ring is instead of the mass fow rate constant during all optimizations. The result from a thermal perspective is an optimal width of the circular ring of nearly zero. The hydraulically optimal inner pipe radius is 54% of the outer pipe radius for laminar fow and 60% for turbulent fow scenarios. Net-exergetic optimization shows a predominant infuence of hydraulic losses, especially for small temperature gains. The exact result depends on the earth’s thermal properties and the fow type. Conclusively, coaxial geothermal probes’ design should focus on the hydraulic optimum and take the thermal optimum as a secondary criterion due to the dominating hydraulics.
This study investigated the anaerobic digestion of an algal–bacterial biofilm grown in artificial wastewater in an Algal Turf Scrubber (ATS). The ATS system was located in a greenhouse (50°54′19ʺN, 6°24′55ʺE, Germany) and was exposed to seasonal conditions during the experiment period. The methane (CH4) potential of untreated algal–bacterial biofilm (UAB) and thermally pretreated biofilm (PAB) using different microbial inocula was determined by anaerobic batch fermentation. Methane productivity of UAB differed significantly between microbial inocula of digested wastepaper, a mixture of manure and maize silage, anaerobic sewage sludge, and percolated green waste. UAB using sewage sludge as inoculum showed the highest methane productivity. The share of methane in biogas was dependent on inoculum. Using PAB, a strong positive impact on methane productivity was identified for the digested wastepaper (116.4%) and a mixture of manure and maize silage (107.4%) inocula. By contrast, the methane yield was significantly reduced for the digested anaerobic sewage sludge (50.6%) and percolated green waste (43.5%) inocula. To further evaluate the potential of algal–bacterial biofilm for biogas production in wastewater treatment and biogas plants in a circular bioeconomy, scale-up calculations were conducted. It was found that a 0.116 km2 ATS would be required in an average municipal wastewater treatment plant which can be viewed as problematic in terms of space consumption. However, a substantial amount of energy surplus (4.7–12.5 MWh a−1) can be gained through the addition of algal–bacterial biomass to the anaerobic digester of a municipal wastewater treatment plant. Wastewater treatment and subsequent energy production through algae show dominancy over conventional technologies.
The present work aimed to study the mainstream feasibility of the deammonifying sludge of side stream of municipal wastewater treatment plant (MWWTP) in Kaster, Germany. For this purpose, the deammonifying sludge available at the side stream was investigated for nitrogen (N) removal with respect to the operational factors temperature (15–30°C), pH value (6.0–8.0) and chemical oxygen demand (COD)/N ratio (≤1.5–6.0). The highest and lowest N-removal rates of 0.13 and 0.045 kg/(m³ d) are achieved at 30 and 15°C, respectively. Different conditions of pH and COD/N ratios in the SBRs of Partial nitritation/anammox (PN/A) significantly influenced both the metabolic processes and associated N-removal rates. The scientific insights gained from the current work signifies the possibility of mainstream PN/A at WWTPs. The current study forms a solid basis of operational window for the upcoming semi-technical trails to be conducted prior to the full-scale mainstream PN/A at WWTP Kaster and WWTPs globally.
Dipl.-Ing. Ralf Engels - DHI Wasser und Umwelt GmbH, Syke. 24 S. (S. 70-93) Beitrag zum 1. Aachener Softwaretag in der Wasserwirtschaft <1,2007, Aachen> Einleitung [des Autors] Die hydrodynamische Kanalnetzmodellierung ist ein Standardwerkzeug für die Bemessung von Kanalnetzen. Neben der Berechnung der hydrologischen und hydraulischen Gegebenheiten in einem städtischen Einzugsgebiet gehören auch weiterführende Technologien mittlerweile zum Standard. So können alle steuerbaren Elemente eines Kanalnetzes dynamisch so optimiert werden, dass die Leistungsfähigkeit des Kanalnetzes zusätzlich gesteigert werden kann. Automatische Werkzeuge zur dynamischen hydraulischen Schmutzfrachtberechnung ermöglichen die Erweiterung der Steuerung – insbesondere von Entlastungsanlagen – im Hinblick auf die entlasteten Schmutzfrachten und geben darüber hinaus detaillierte Informationen für den Betrieb der Kläranlage. Weiterführende biologische Prozessmodellierungen ergänzen dieses Themenfeld. GIS Werkzeuge können bei der räumlich differenzierten Modellierung von Kanalnetzen wertvolle Dienste leisten. Die detaillierte Betrachtung einzelner Haltungsflächen in ihrem räumlichen Zusammenhang ist damit ebenso möglich wie eine komplette Verwaltung aller für die Kanalnetzmodellierung notwendigen Daten in einem übersichtlichen grafischen Menü. Die Grenzen der Kanalnetzmodellierung lagen in früheren Zeiten an dessen Rand. Detaillierte Informationen über die Wege des Wassers auf der Geländeoberfläche, an der Schnittstelle zu Vorflutern und in der Interaktion mit Grundwasser waren bisher nicht modelltechnisch bewertbar. Eine dynamische Kopplung verschiedener Modelle zur Darstellung aller relevanten hydraulischen Prozesse ermöglicht eine integrative Betrachtung aller möglichen Wege, die das Wasser in der Stadt nehmen kann (Mark & Djordjevic, 2006). Dieser Beitrag präsentiert den Stand der Technik für die integrierte Modellierung städtischer Überschwemmungen mit Hilfe der Modellkopplung von Oberflächenmodellen und Kanalnetzmodellen.