Refine
Year of publication
- 2004 (323) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (85)
- Fachbereich Wirtschaftswissenschaften (37)
- Fachbereich Elektrotechnik und Informationstechnik (35)
- Fachbereich Energietechnik (35)
- INB - Institut für Nano- und Biotechnologien (35)
- IfB - Institut für Bioengineering (30)
- Fachbereich Maschinenbau und Mechatronik (24)
- Fachbereich Luft- und Raumfahrttechnik (23)
- Fachbereich Bauingenieurwesen (20)
- Fachbereich Chemie und Biotechnologie (15)
Language
- English (161)
- German (160)
- Portuguese (2)
Document Type
- Article (214)
- Conference Proceeding (37)
- Book (35)
- Lecture (6)
- Report (6)
- Part of a Book (5)
- Doctoral Thesis (4)
- Patent (4)
- Study Thesis (4)
- Other (3)
Keywords
- Bauingenieurwesen (4)
- Betriebswirtschaftslehre (4)
- Bologna-Prozess (4)
- CAD (4)
- ECTS (4)
- Filmregie (4)
- Finanzierung (4)
- Liquiditätspolitik (4)
- civil engineering (4)
- Aachen University of Applied Sciences (3)
- Arbeitsbelastung (3)
- European Credit Transfer System (3)
- Europäisches Leistungspunktesystem (3)
- Fachhochschule Aachen (3)
- Hochschuldidaktik (3)
- Mediendesign (3)
- Project (3)
- Workload (3)
- Didactics (2)
- Dokumentarfilm (2)
- Elektromagnetischer Schutzschild (2)
- Fernsehen (2)
- Fernsehsendung (2)
- Film design (2)
- Filmdesign (2)
- Führung (2)
- Karosseriebau (2)
- Kurzfilm (2)
- Leadership (2)
- Leichtbau (2)
- Projektarbeit (2)
- Regie (2)
- Studienarbeit (2)
- Talkshow (2)
- Television (2)
- Television show (2)
- blended learning (2)
- 3D-Printing (1)
- Audio-visual Art (1)
- Bachelor (1)
- Bewertung von Studienleistungen (1)
- Bewertung von Studienleistungen . Ingenieurstudiengänge (1)
- Bewertung von Studienleistungen . Studierendenmobilität (1)
- Black-and-white-film (1)
- Blitz (1)
- Blitzrisiko (1)
- Blitzschlag (1)
- Blitzschutz (1)
- Direct lightning strike (1)
- Direkter Blitzschlag (1)
- Druckbeanspruchung (1)
- Druckbehälter (1)
- Druckbelastung (1)
- E-Learning (1)
- Einspielen <Werkstoff> (1)
- Elektronische Kunst (1)
- Extrusionsverfahren (1)
- FLM (1)
- Fehlerstellen (1)
- Fibroblast (1)
- Fließgrenze (1)
- Forschungsbericht (1)
- Froschperspektive (1)
- Fused deposition modelling (1)
- Führungserfolg (1)
- Führungskraft (1)
- Gießharzwerkzeuge (1)
- Grundstudium (1)
- Handheld camera (1)
- Handkamera (1)
- Hybrid Art (1)
- Hybride Kunst (1)
- Induzierte Spannungen (1)
- Ingenieurstudiengänge (1)
- Kalkulation (1)
- Kamera (1)
- Karosserieleichtbau (1)
- Karosserietechnik (1)
- Klangkunst (1)
- Knochen (1)
- Knochenbildung (1)
- Knochenchirugie (1)
- Knochendichte (1)
- Kontaktstunden (1)
- Laminat Verfahren (1)
- Laminated-Object-Manufacturing (1)
- Lasersintern (1)
- Laserstrahlsintern (1)
- Leader (1)
- Learning Outcomes (1)
- Leichtbauwerkstoffe (1)
- Leistungspunktsysteme (1)
- Lernprogramm (1)
- Lightning (1)
- Lightning Protection (1)
- Lightning Risk (1)
- Magnetische Felder (1)
- Master (1)
- Materialmischbauweise (1)
- Maßstabsgetreues Modell (1)
- Mechanische Beanspruchung (1)
- Medienkunst (1)
- Modularisierung (1)
- Motivation (1)
- Organisationale Führung (1)
- Parodie (1)
- Projekt (1)
- Rapid prototyping (1)
- Research report (1)
- Risiko (1)
- Risikoabwägung (1)
- Risk (1)
- Risk Assessment (1)
- Risk Management (1)
- Rohr (1)
- Rohrbruch (1)
- Schwammknochen (1)
- Schwarz-Weiß-Film (1)
- Shakedown (1)
- Shortfilm (1)
- Sound Art (1)
- Stahl (1)
- Stahlbeton (1)
- Stereolithographie (1)
- Strukturanalyse (1)
- Studienprojekt (1)
- Stummfilm (1)
- Success (1)
- Temperaturabhängigkeit (1)
- UML (1)
- Unified Modeling Language (1)
- Vakuumgießen (1)
- Video (1)
- Video film (1)
- Videofilm (1)
- Wolff's Law (1)
- Wolffsches Gesetz (1)
- Worm's-eye view (1)
- avalanche (1)
- bone density (1)
- bone structure (1)
- burst pressure (1)
- burst tests (1)
- calculations (1)
- cancellous bone (1)
- car body construction (1)
- celldrum technology (1)
- electromagnetic shield (1)
- electromagnetic shielding (1)
- film directing (1)
- flaw (1)
- induced voltages (1)
- load limit (1)
- magnetic fields (1)
- pipes (1)
- reinforced concrete (1)
- scaled model (1)
- shakedown analysis (1)
- vessels (1)
- yield stress (1)
For the application of the concept of Lightning Protection Zones (LPZ), the knowledge of the magnetic fields and induced voltages inside a structure is necessary. Laboratory experiments have been conducted at a downscaled model of a building (scale factor 1:6) to determine these electromagnetic quantities in case of a direct strike to the structure. The model (3 m x 2 m x 2 m) represented a small industrial building using the reinforcement of the concrete as electromagnetic shield. The magnetic fields and magnetic field derivatives were measured at several location inside the scaled model. Further, the voltages induced on three typical cable routes inside the model was determined. The influence of the lightning current waveshape, point-of-strike, bonding of the cable routes, and bridging of an expansion joint in the middle of the building on these quantities was studied.
The ClearPET™ project is proposed by working groups of the Crystal Clear Collaboration (CCC) to develop a 2nd generation high performance small animal positron emission tomograph (PET). High sensitivity and high spatial resolution is foreseen for the ClearPET™ camera by using a phoswich arrangement combining mixed lutetium yttrium aluminum perovskite (LuYAP:Ce) and lutetium oxyorthosilicate (LSO) scintillating crystals. Design optimizations for the first photomultiplier tube (PMT) based ClearPET camera are done with a Monte-Carlo simulation package implemented on GEANT3 (CERN, Geneva, Switzerland). A dual-head prototype has been built to test the frontend electronics and was used to validate the implementation of the GEANT3 simulation tool. Multiple simulations were performed following the experimental protocols to measure the intrinsic resolution and the sensitivity profile in axial and radial direction. Including a mean energy resolution of about 27.0% the simulated intrinsic resolution is about (1.41±0.11)mm compared to the measured of (1.48±0.06)mm. The simulated sensitivity profiles show a mean square deviation of 12.6% in axial direction and 3.6% in radial direction. Satisfactorily these results are representative for all designs and confirm the scanner geometry.
A 2nd generation high performance small animal PET scanner, called ClearPET™, has been designed and a first prototype is built by working groups of the Crystal Clear Collaboration (CCC). In order to achieve high sensitivity and maintain good uniform spatial resolution over the field of view in high resolution PET systems, it is necessary to extract the depth of interaction (DOI) information and correct for spatial degradation. The design of the first ClearPET™ Demonstrator based on the use of the multi-anode photomultiplier tube (Hamamatsu R7600-M64) and a LSO/LuYAP phoswich matrix. The two crystal layers of 8*8 crystals (2*2*10 mm3) are stacked on each other and mounted without light guide as one to one on the PMT. A unit of four PMTs arranged in-line represents one of 20 sectors of the ring design. The opening diameter of the crystal ring is 137 mm, the axial detector length is 110 mm. The PMT pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the pulse arrival time. Single gamma interactions are recorded and coincidences are found by software. The gantry allows rotation of the detector modules around the field of view. The measurements have been done using the first LSO/LuYAP detector cassettes.