Refine
Year of publication
- 2008 (157) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (53)
- IfB - Institut für Bioengineering (33)
- Fachbereich Elektrotechnik und Informationstechnik (27)
- Fachbereich Energietechnik (17)
- Fachbereich Luft- und Raumfahrttechnik (12)
- Fachbereich Wirtschaftswissenschaften (11)
- INB - Institut für Nano- und Biotechnologien (10)
- Fachbereich Chemie und Biotechnologie (9)
- Fachbereich Maschinenbau und Mechatronik (8)
- Solar-Institut Jülich (7)
Language
- English (157) (remove)
Document Type
- Article (103)
- Conference Proceeding (37)
- Book (7)
- Part of a Book (4)
- Doctoral Thesis (3)
- Lecture (1)
- Patent (1)
- Report (1)
Keywords
- Finite-Elemente-Methode (2)
- Limit analysis (2)
- Shakedown analysis (2)
- Telekommunikationsmarkt (2)
- Actuators (1)
- Aktor (1)
- Aktoren (1)
- First-order reliability method (1)
- Kohlenstofffaser (1)
- Lipopolysaccharide (1)
- Microfabrication (1)
- Sensitivity (1)
- Sensor (1)
- Sensoren (1)
- Sensores (1)
- avalanche (1)
- body limbs (1)
- deserts (1)
- lipopolysaccharides (1)
- lizards (1)
- magnetic resonance imaging (1)
- nanostructured carbonized plant parts (1)
- nanostrukturierte carbonisierte Pflanzenteile (1)
- second-order reliability method (1)
- snow (1)
- swimming (1)
Beyond ClearPET: Next Aims
(2008)
The CRYSTAL CLEAR collaboration, in short CCC, is a consortium of 12 academic institutions, mainly from Europe, joining efforts in the area of developing instrumentation for nuclear medicine and medical imaging. In the framework of the CCC a high performance small animal PET system, called ClearPET, was developed by using new technologies in electronics and crystals in a phoswich arrangement combining two types of lutetium- based scintillator materials: LSO:Ce and LuYAP:Ce. Our next aim will be the development of hybrid image systems. Hybrid MR-PET imaging has many unique advantages for brain research. This has sparked a new research line within CCC for the development of novel MR-PET compatible technologies. MRI is not as sensitive as PET but PET has poorer spatial resolution than MRI. Two major advantages of PET are sensitivity and its ability to acquire metabolic information. To assess these innovations, the development of a 9.4T hybrid animal MR-PET scanner is proposed based on an existing 9.4T MR scanner that will be adapted to enable simultaneous acquisition of MR and PET data using cutting- edge technology for both MR and PET.
Due to the interfering effects of acetic acid in many fermentation processes, a gas-diffusion technique was developed for the online determination of acetic acid. The measurements were accomplished with a flow diffusion analysis (FDA) unit from the TRACE Analytics GmbH, Braunschweig, Germany. The diffusion analysis is based on the UV-absorbance of acetic acid at 205 nm. The measurement was achieved by the separation of an acceptor and a carrier stream (acidified fermentation broth) using a gas permeable polytetrafluoroethylene (PTFE) membrane, whereby broth constituents that would otherwise disturb the UV-measurement of acetic acid, are held back efficiently. Merely, the fermentation by-products, e.g. formic acid, is capable of diffusing through the membrane. While formic acid can disturb the measurement, carbon dioxide does not absorb at 205 nm. The method operates with time-dependent sample enrichment. During the analysis, a small volume of the acceptor stream is stopped for a defined time interval in the acceptor chamber. During this period, the gaseous acetic acid diffuses through the membrane and is enriched in the acceptor chamber. Subsequently after the enrichment, the acceptor stream flows through a UV-detector. The intensity of the signal is proportional to the acetic acid concentration. Online measurements in bioreactors via a sterile filtration probe have been accomplished. A linear calibration in the range of 0.5–5.0 g/L acetic acid with a relative standard deviation of <5 % was obtained. A sampling rate of 8 samples per hour was possible. The system was applied for the determination of acetic acid in E. coli fermentation broth. The instrument is easy to clean, very user-friendly and does not require any toxic or expensive reagents.
Plant growth and transport processes are highly dynamic. They are characterized by plant-internal control processes and by strong interactions with the spatially and temporally varying environment. Analysis of structure- function relations of growth and transport in plants will strongly benefit from the development of non-invasive techniques. PlanTIS (Plant Tomographic Imaging System) is designed for non-destructive 3D-imaging of positron emitting radiotracers. It will permit functional analysis of the dynamics of carbon distribution in plants including bulky organs. It will be applicable for screening transport properties of plants to evaluate e.g. temperature adaptation of genetically modified plants. PlanTIS is a PET scanner dedicated to monitor the dynamics of the 11C distribution within a plant while or after assimilation of 11CO2. Front end electronics and data acquisition architecture of the scanner are based on the ClearPETTM system [1]. Four detector modules form one of two opposing detector blocks. Optionally, a hardware coincidence detection between the blocks can be applied. In general the scan duration is rather long (~ 1 hour) compared to the decay time of 11C (20 min). As a result the count rates can vary over a wide range and accurate dead time correction is necessary.
7th International Conference on Reliability of Materials and Structures (RELMAS 2008). June 17 - 20, 2008 ; Saint Petersburg, Russia. pp 354-358. Reprint with corrections in red Introduction Analysis of advanced structures working under extreme heavy loading such as nuclear power plants and piping system should take into account the randomness of loading, geometrical and material parameters. The existing reliability are restricted mostly to the elastic working regime, e.g. allowable local stresses. Development of the limit and shakedown reliability-based analysis and design methods, exploiting potential of the shakedown working regime, is highly needed. In this paper the application of a new algorithm of probabilistic limit and shakedown analysis for shell structures is presented, in which the loading and strength of the material as well as the thickness of the shell are considered as random variables. The reliability analysis problems may be efficiently solved by using a system combining the available FE codes, a deterministic limit and shakedown analysis, and the First and Second Order Reliability Methods (FORM/SORM). Non-linear sensitivity analyses are obtained directly from the solution of the deterministic problem without extra computational costs.
Load bearing capacity of thin shell structures made of elastoplastic material by direct methods
(2008)
Soft Materials in Technology and Biology – Characteristics, Properties, and Parameter Identification
(2008)
Sensing charged macromolecules with nanocrystalline diamond-based field-effect capacitive sensors
(2008)
Optoelectronic Properties of Nanostructured Ensembles Controlled by Biomolecular Logic Systems
(2008)
[Skripte]
(2008)
The sorption of LPS toxic shock by nanoparticles on base of carbonized vegetable raw materials
(2008)
Immobilization of lactobacillus on high temperature carbonizated vegetable raw material (rice husk, grape stones) increases their physiological activity and the quantity of the antibacterial metabolits, that consequently lead to increase of the antagonistic activity of lactobacillus. It is implies that the use of the nanosorbents for the attachment of the probiotical microorganisms are highly perspective for decision the important problems, such as the probiotical preparations delivery to the right address and their attachment to intestines mucosa with the following detoxication of gastro-intestinal tract and the normalization of it’s microecology. Besides that, thus, the received carbonizated nanoparticles have peculiar properties – ability to sorption of LPS toxical shock and, hence, to the detoxication of LPS.
Time-of-flight (ToF) sensors have become an alternative to conventional distance sensing techniques like laser scanners or image based stereo. ToF sensors provide full range distance information at high frame-rates and thus have a significant impact onto current research in areas like online object recognition, collision prevention or scene reconstruction. However, ToF cameras like the photonic mixer device (PMD) still exhibit a number of challenges regarding static and dynamic effects, e.g. systematic distance errors and motion artefacts, respectively. Sensor calibration techniques reducing static system errors have been proposed and show promising results. However, current calibration techniques in general need a large set of reference data in order to determine the corresponding parameters for the calibration model. This paper introduces a new calibration approach which combines different demodulation techniques for the ToF- camera 's reference signal. Examples show, that the resulting combined demodulation technique yields improved distance values based on only two required reference data sets.
Password necessarily. Access only for Students by Prof. Dr. Klaus-Peter Kämper. Winter semester 2008/2009. 488 pages (pdf) Contents 1. Introduction 2. Introduction to Sensors 3. Introduction to Microfabrication 4. Pressure Sensors 5. Acceleration Sensors 6. Angular Rate Sensors 7. Position Sensors 8. Flow Sensors 9. Piezoelectric Actuators 10. Magnetostrictive Actuators 11. Actuators based on Shape Memory Alloys 12. Actuators based on Electrorheological Fluids 13. Actuators based on Magnetorheological Fluids 14. Index
Solar tower power plants
(2008)