Refine
Year of publication
Document Type
- Conference Proceeding (91)
- Article (47)
- Lecture (3)
- Report (2)
- Course Material (1)
- Other (1)
Has Fulltext
- yes (145) (remove)
Keywords
- Biosensor (25)
- Finite-Elemente-Methode (16)
- CAD (15)
- civil engineering (14)
- Bauingenieurwesen (13)
- Einspielen <Werkstoff> (13)
- shakedown analysis (8)
- FEM (6)
- Clusterion (5)
- limit analysis (5)
- Air purification (4)
- Einspielanalyse (4)
- Hämoglobin (4)
- Limit analysis (4)
- Luftreiniger (4)
- Plasmacluster ion technology (4)
- Raumluft (4)
- Shakedown (4)
- Shakedown analysis (4)
- Technische Mechanik (4)
- Traglast (4)
- Traglastanalyse (4)
- shakedown (4)
- Kohlenstofffaser (3)
- Lipopolysaccharide (3)
- Sonde (3)
- lipopolysaccharides (3)
- ratchetting (3)
- Analytischer Zulaessigkeitsnachweis (2)
- Architektur (2)
- Bruchmechanik (2)
- Capacitive field-effect sensor (2)
- Druckbeanspruchung (2)
- Druckbehälter (2)
- Druckbelastung (2)
- Einspiel-Analyse (2)
- Eisschicht (2)
- Erythrozyt (2)
- Fehlerstellen (2)
- Fibroblast (2)
- Label-free detection (2)
- Pflanzenphysiologie (2)
- Pflanzenscanner (2)
- Ratcheting (2)
- Rohr (2)
- Rohrbruch (2)
- Stahl (2)
- Stickstoffmonoxid (2)
- architecture (2)
- biosensor (2)
- biosensors (2)
- burst pressure (2)
- burst tests (2)
- capacitive field-effect sensors (2)
- celldrum technology (2)
- flaw (2)
- limit load (2)
- load limit (2)
- nanostructured carbonized plant parts (2)
- nanostrukturierte carbonisierte Pflanzenteile (2)
- nitric oxide gas (2)
- pipes (2)
- plant scanner (2)
- tension–torsion loading (2)
- vessels (2)
- 3-nitrofluoranthene (1)
- Adsorption (1)
- Alternating plasticity (1)
- Analysis (1)
- Anastomose (1)
- Anastomosis (1)
- Architectural design (1)
- Arthosetherapie (1)
- Aufschlagversuch (1)
- Autofluoreszenzverfahren (1)
- Axialbelastung (1)
- Axially cracked pipe (1)
- BTEX compounds (1)
- Bacterial cellulose (1)
- Bakterien (1)
- Basis Reduktion (1)
- Basis reduction (1)
- Bicharakteristikenverfahren (1)
- Bio-Sensors (1)
- Bioabsorbable (1)
- Biomechanics (1)
- Biomechanik (1)
- Biomedizinische Technik (1)
- Biophoton (1)
- Bioreaktor (1)
- Biosensorik (1)
- Blitzschutz (1)
- Blutzellenlagerung (1)
- Bone quality and biomechanics (1)
- CAD ; (1)
- CO (1)
- Carbon sources (1)
- Cellulose nanostructure (1)
- Cement infiltration (1)
- Conducing polymer (1)
- Convex optimization (1)
- Cost-effectiveness (1)
- Culture media (1)
- Dattel (1)
- Deformation (1)
- Dekontamination (1)
- Design-by-analysis (1)
- Druckgeräte (1)
- ECT (1)
- ELISA (1)
- EPN (1)
- Einspiel-Kriterium (1)
- Einspielen (1)
- Elastizität (1)
- Elastodynamik (1)
- Elastostatics (1)
- Elektrodynamik (1)
- Endothelzelle (1)
- Enterprise information systems (1)
- Environmental impact (1)
- Enzyme-linked immunosorbent assay (1)
- Epithel (1)
- Exact Ilyushin yield surface (1)
- Experiment (1)
- FEM-Programm (1)
- FEM-computation (1)
- Fault approximation (1)
- Fault detection (1)
- Festkörper (1)
- Finite element method (1)
- First Order Reliabiblity Method (1)
- First-order reliability method (1)
- Fließgrenze (1)
- Fluorescence (1)
- Fußball (1)
- GaAs hot electron injector (1)
- Gas sensor (1)
- Geriatric (1)
- German (1)
- Global and local collapse (1)
- Gold nanoparticles (1)
- Gonarthrose (1)
- Grenzwertberechnung (1)
- Gunn diode (1)
- Harnleiter (1)
- Heavy metal detection (1)
- Hemoglobin structure (1)
- High throughput experimentation (1)
- Hip fractures (1)
- Hotplate (1)
- Human Factors (1)
- Hydrodynamik (1)
- Hydrogel (1)
- Hydrogen sensor (1)
- Hämoglobinstruktur (1)
- I3S 2005 (1)
- ISFET (1)
- Information Integration Tools (1)
- Information extraction (1)
- International Symposium on Sensor Science (1)
- Inverse scattering problem (1)
- Kinematics (1)
- Kinetics (1)
- Kniegelenkarthrose (1)
- Knochen (1)
- Knochenbildung (1)
- Knochenchirugie (1)
- Knochendichte (1)
- Knowledge Management (1)
- Körpertemperatur (1)
- LED chip (1)
- LISA (1)
- Level sensor (1)
- Lichtstreuungsbasierte Instrumente (1)
- MBST (1)
- MCDA (1)
- MEMS (1)
- Main sensitivity (1)
- Materialermüdung (1)
- Mechanics (1)
- Mechanische Beanspruchung (1)
- Medusomyces gisevi (1)
- Microreactors (1)
- Model-driven software engineering (1)
- Multi-dimensional wave propagation (1)
- Multicell (1)
- Multiplexing (1)
- Nano Materials (1)
- Nanomaterial (1)
- Nanoparticles (1)
- Nanopartikel (1)
- Nanostructuring (1)
- Nanotechnologie (1)
- Nanotechnology ; Microelectronics ; Biosensors ; Superconductor ; MEMS (1)
- Natriumhypochlorit (1)
- Nichtlineare Gleichung (1)
- Nichtlineare Optimierung (1)
- Nichtlineare Welle (1)
- Ontologie <Wissensverarbeitung> (1)
- Ontology Engineering (1)
- Organkultur (1)
- Organophosphorus (1)
- Ostazine Orange (1)
- Osteoporose (1)
- Osteoporosis (1)
- PFM (1)
- Permeability (1)
- Permeabilität (1)
- Peroxidase (1)
- Pflanzenstress (1)
- Phenylalanine determination (1)
- Plant virus (1)
- Plastizität (1)
- Polylactide acid (1)
- Potentiometry (1)
- Pressure loaded crack-face (1)
- Prevention (1)
- Progressive plastic deformation (1)
- Prophylaxis (1)
- Proteine (1)
- Pseudomonas putida (1)
- Quartz crystal nanobalance (QCN) (1)
- Quartz micro balances (1)
- Random variable (1)
- Ratchetting (1)
- Reaction-diffusion (1)
- Red blood cell storage (1)
- Resistive temperature detector (1)
- Schienbeinschoner (1)
- Schwammknochen (1)
- Sensitivity (1)
- Sepsis (1)
- Shakedown criterion (1)
- Silk fibroin (1)
- Skeletal muscle (1)
- Small Aral Sea (1)
- Software and systems modeling (1)
- Solid amalgam electrodes (1)
- Statics (1)
- Strukturanalyse (1)
- Supraleiter (1)
- Temperaturabhängigkeit (1)
- Tendons (1)
- Tin oxide (1)
- Tissue Engineering (1)
- Tobacco mosaic virus (TMV) (1)
- Torsion (1)
- Torsionsbelastung (1)
- Tragfähigkeit (1)
- UML (1)
- Ultrasound (1)
- Unified Modeling Language (1)
- Vertebroplastie (1)
- Vertebroplasty (1)
- Viscous flow (1)
- Viskose Strömung (1)
- Viskosität (1)
- Wafer (1)
- Wasserbrücke (1)
- Wasserstoffperoxid (1)
- Wellen (1)
- Wolff's Law (1)
- Wolffsches Gesetz (1)
- Wundheilung (1)
- Zeta potential (1)
- Zug-Druck Belastung (1)
- Zug-Druck-Beanspruchung (1)
- Zug-Druck-Belastung (1)
- acetoin (1)
- acetoin reductase (1)
- activated nanostructured carbon (1)
- aktivierte nanostrukturierte Kohlenstofffaser (1)
- alcoholic beverages (1)
- alternierend Verformbarkeit (1)
- ammonia gas sensors (1)
- amperometric biosensors (1)
- amperometric sensor (1)
- antimony doped tin oxide (1)
- aromatic amines (1)
- arthrosis therapy (1)
- atomic layer deposition (1)
- autofluorescence-based detection system (1)
- bicharacteristics (1)
- bioburdens (1)
- biocompatible (1)
- biocompatible materials (1)
- biodegradabl (1)
- biodegradable electronic devices (1)
- bone density (1)
- bone structure (1)
- cancellous bone (1)
- capacitive electrolyte–insulator–semiconductor sensors (1)
- capillary micro-droplet cell (1)
- carbon electrodes (1)
- carbonized rice husk (1)
- carcinogens (1)
- catalytic decomposition (1)
- chemical reduction method (1)
- contractile tension (1)
- cross sensitivity (1)
- cytosolic water diffusion (1)
- date palm tree (1)
- design-by-analysis (1)
- direct method (1)
- doped metal oxide (1)
- doped silicon (1)
- doping (1)
- ecological structure (1)
- elastic solids (1)
- electrical capacitance tomography (1)
- electro-migration (1)
- electronic noses dendronized polymers inverted mesa technology (1)
- encapsulation materials (1)
- enzymatic biosensor (1)
- enzymatic methods (1)
- enzyme immobilisation (1)
- epithelization (1)
- fatigue analyses (1)
- fenitrothion (1)
- fibroin (1)
- finite element analysis (1)
- fluidic (1)
- fortschreitende plastische Deformation (1)
- gas sensor (1)
- gas sensor array (1)
- glucose (1)
- gonarthrosis (1)
- graphene oxide (1)
- heater metallisation (1)
- hemoglobin (1)
- hemoglobin dynamics (1)
- high-temperature stability (1)
- human dermal fibroblasts (1)
- humidity (1)
- hydrogel (1)
- hydrogen peroxide (1)
- image sensor (1)
- imaging (1)
- impedance spectroscopy (1)
- ion-selective electrodes (1)
- kontraktile Spannung (1)
- konvexe Optimierung (1)
- lab-on-a-chip (1)
- lab-on-chip (1)
- large language models (1)
- layer expansion (1)
- layer-by-layer technique (1)
- lenslet array (1)
- light scattering analysis (1)
- lightning flash (1)
- limit and shakedown analysis (1)
- linear kinematic hardening (1)
- load carrying capacity (1)
- lower bound theorem (1)
- magnetic particles (1)
- material shakedown (1)
- matrix method (1)
- mechanical waves (1)
- metagenomics (1)
- metal oxide (1)
- microbial diversity (1)
- microreactor (1)
- microwave generation (1)
- modeling biosensor (1)
- modelling (1)
- modified electrode (1)
- multi-interface measurement (1)
- nanomaterials (1)
- naphtols (1)
- nitrogen oxides (1)
- nonlinear kinematic hardening (1)
- nonlinear optimization (1)
- nonlinear solids (1)
- nonlinear tensor constitutive equation (1)
- organic PVC membranes (1)
- pH sensors (1)
- pH-based biosensing (1)
- pattern-size reduction (1)
- penicillin (1)
- penicillinase (1)
- phenols (1)
- photoelectrochemistry (1)
- plant stress (1)
- plasma generated ions (1)
- plastic deformation (1)
- polyaniline (1)
- polymer composites (1)
- porous Pt electrode (1)
- principal component (1)
- probabilistic fracture mechanics (1)
- protein (1)
- quantum charging (1)
- reliability (1)
- reliability analysis (1)
- rhAPC (1)
- screen-printing (1)
- second-order reliability method (1)
- self-aligned patterning (1)
- semantic role labeling (1)
- sensing properties (1)
- shakedown analyses (1)
- shotgun sequencing (1)
- speaker attribution (1)
- sterilisation (1)
- sterility tests (1)
- sterilization efficacy (1)
- sterilization methods (1)
- subsurface ice research (1)
- subsurface probe (1)
- surface modification (1)
- swift heavy ions (1)
- thermal ratcheting (1)
- thick-film technology (1)
- thin-film microsensors (1)
- titanium dioxide photoanode (1)
- ultrathin gate insulators (1)
- validation methods (1)
- voltammetry (1)
- wafer-level testing (1)
- water bridge phenomenon (1)
- wound healing (1)
- yield stress (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (145) (remove)
Companies often build their businesses based on product information and therefore try to automate the process of information extraction (IE). Since the information source is usually heterogeneous and non-standardized, classic extract, transform, load techniques reach their limits. Hence, companies must implement the newest findings from research to tackle the challenges of process automation. They require a flexible and robust system that is extendable and ensures the optimal processing of the different document types. This paper provides a distributed microservice architecture pattern that enables the automated generation of IE pipelines. Since their optimal design is individual for each input document, the system ensures the ad-hoc generation of pipelines depending on specific document characteristics at runtime. Furthermore, it introduces the automated quality determination of each available pipeline and controls the integration of new microservices based on their impact on the business value. The introduced system enables fast prototyping of the newest approaches from research and supports companies in automating their IE processes. Based on the automated quality determination, it ensures that the generated pipelines always meet defined business requirements when they come into productive use.
Micromachined thermal heater platforms offer low electrical power consumption and high modulation speed, i.e. properties which are advantageous for realizing nondispersive infrared (NDIR) gas- and liquid monitoring systems. In this paper, we report on investigations on silicon-on-insulator (SOI) based infrared (IR) emitter devices heated by employing different kinds of metallic and semiconductor heater materials. Our results clearly reveal the superior high-temperature performance of semiconductor over metallic heater materials. Long-term stable emitter operation in the vicinity of 1300 K could be attained using heavily antimony-doped tin dioxide (SnO2:Sb) heater elements.
Study of swift heavy ion modified conduction polymer composites for application as gas sensor
(2006)
A polyaniline-based conducting composite was prepared by oxidative polymerisation of aniline in a polyvinylchloride (PVC) matrix. The coherent free standing thin films of the composite were prepared by a solution casting method. The polyvinyl chloride-polyaniline composites exposed to 120 MeV ions of silicon with total ion fluence ranging from 1011 to 1013 ions/cm2, were observed to be more sensitive towards ammonia gas than the unirradiated composite. The response time of the irradiated composites was observed to be comparably shorter. We report for the first time the application of swift heavy ion modified insulating polymer conducting polymer (IPCP) composites for sensing of ammonia gas.
Improved collapse loads of thick-walled, crack containing pipes and vessels are suggested. Very deep cracks have a residual strength which is better modelled by a global limit load. In all burst tests, the ductility of pressure vessel steels was sufficiently high whereby the burst pressure could be predicted by limit analysis with no need to apply fracture mechanics. The relative prognosis error increases however, for long and deep defects due to uncertainties of geometry and strength data.
Fatigue analyses are conducted with the aim of verifying that thermal ratcheting is limited. To this end it is important to make a clear distintion between the shakedown range and the ratcheting range (continuing deformation). As part of an EU-supported research project, experiments were carried out using a 4-bar model. The experiment comprised a water-cooled internal tube, and three insulated heatable outer test bars. The system was subjected to alternating axial forces, superimposed with alternating temperatures at the outer bars. The test parameters were partly selected on the basis of previous shakedown analyses. During the test, temperatures and strains were measured as a function of time. The loads and the resulting stresses were confirmed on an ongoing basis during performance of the test, and after it. Different material models were applied for this incremental elasto-plastic analysis using the ANSYS program. The results of the simulation are used to verify the FEM-based shakedown analysis.
Limit loads can be calculated with the finite element method (FEM) for any component, defect geometry, and loading. FEM suggests that published long crack limit formulae for axial defects under-estimate the burst pressure for internal surface defects in thick pipes while limit loads are not conservative for deep cracks and for pressure loaded crack-faces. Very deep cracks have a residual strength, which is modelled by a global collapse load. These observations are combined to derive new analytical local and global collapse loads. The global collapse loads are close to FEM limit analyses for all crack dimensions.
In the new European standard for unfired pressure vessels, EN 13445-3, there are two approaches for carrying out a Design-by-Analysis that cover both the stress categorization method (Annex C) and the direct route method (Annex B) for a check against global plastic deformation and against progressive plastic deformation. This paper presents the direct route in the language of limit and shakedown analysis. This approach leads to an optimization problem. Its solution with Finite Element Analysis is demonstrated for mechanical and thermal actions. One observation from the examples is that the so-called 3f (3Sm) criterion fails to be a reliable check against progressive plastic deformation. Precise conditions are given, which greatly restrict the applicability of the 3f criterion.
Structural design analyses are conducted with the aim of verifying the exclusion of ratchetting. To this end it is important to make a clear distinction between the shakedown range and the ratchetting range. The performed experiment comprised a hollow tension specimen which was subjected to alternating axial forces, superimposed with constant moments. First, a series of uniaxial tests has been carried out in order to calibrate a bounded kinematic hardening rule. The load parameters have been selected on the basis of previous shakedown analyses with the PERMAS code using a kinematic hardening material model. It is shown that this shakedown analysis gives reasonable agreement between the experimental and the numerical results. A linear and a nonlinear kinematic hardening model of two-surface plasticity are compared in material shakedown analysis.
Limit and shakedown analysis are effective methods for assessing the load carrying capacity of a given structure. The elasto–plastic behavior of the structure subjected to loads varying in a given load domain is characterized by the shakedown load factor, defined as the maximum factor which satisfies the sufficient conditions stated in the corresponding static shakedown theorem. The finite element dicretization of the problem may lead to very large convex optimization. For the effective solution a basis reduction method has been developed that makes use of the special problem structure for perfectly plastic material. The paper proposes a modified basis reduction method for direct application to the two-surface plasticity model of bounded kinematic hardening material. The considered numerical examples show an enlargement of the load carrying capacity due to bounded hardening.