Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (1594) (remove)
Document Type
- Article (1594) (remove)
Keywords
- Einspielen <Werkstoff> (7)
- FEM (4)
- Finite-Elemente-Methode (4)
- LAPS (4)
- CellDrum (3)
- Label-free detection (3)
- biosensors (3)
- hydrogen peroxide (3)
- impedance spectroscopy (3)
- shakedown analysis (3)
A Classical Reformulation of Finite-Dimensional Quantum Mechanics. Hellwig, K.-E.; Stulpe, W.
(1993)
Macroporous silicon has been etched from n-type Si, using a vertical etching cell where no rear side contact on the silicon wafer is necessary. The resulting macropores have been characterised by means of Scanning Electron Microscopy (SEM). After etching, SiO₂ was thermally grown on the top of the porous silicon as an insulating layer and Si₃N₄ was deposited by means of Low Pressure Chemical Vapour Deposition (LPCVD) as transducer material to fabricate a capacitive pH sensor. In order to prepare porous biosensors, the enzyme penicillinase has been additionally immobilised inside the porous structure. Electrochemical measurements of the pH sensor and the biosensor with an Electrolyte/Insulator/Semiconductor (EIS) structure have been performed in the Capacitance/Voltage (C/V) and Constant capacitance (ConCap) mode.
468 Scatter dose determination at the eye lens during a mask based whole brain radiotherapy (WBRT)
(2005)
For performing point-of-care molecular diagnostics, magnetic immunoassays constitute a promising alternative to established enzyme-linked immunosorbent assays (ELISA) because they are fast, robust and sensitive. Simultaneous detection of multiple biomolecular targets from one body fluid sample is desired. The aim of this work is to show that multiplex magnetic immunodetection based on magnetic frequency mixing by means of modular immunofiltration columns prepared for different targets is feasible. By calculations of the magnetic response signal, the required spacing between the modules was determined. Immunofiltration columns were manufactured by 3D printing and antibody immobilization was performed in a batch approach. It was shown experimentally that two different target molecules in a sample solution could be individually detected in a single assaying step with magnetic measurements of the corresponding immobilization filters. The arrangement order of the filters and of a negative control did not influence the results. Thus, a simple and reliable approach to multi-target magnetic immunodetection was demonstrated.