Refine
Year of publication
- 2010 (343) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (73)
- Fachbereich Wirtschaftswissenschaften (41)
- IfB - Institut für Bioengineering (40)
- Fachbereich Elektrotechnik und Informationstechnik (36)
- Fachbereich Chemie und Biotechnologie (35)
- Fachbereich Energietechnik (35)
- Fachbereich Maschinenbau und Mechatronik (31)
- Fachbereich Bauingenieurwesen (24)
- Fachbereich Luft- und Raumfahrttechnik (24)
- INB - Institut für Nano- und Biotechnologien (23)
Language
- English (187)
- German (153)
- Italian (2)
- Multiple languages (1)
Document Type
- Article (141)
- Conference Proceeding (100)
- Book (38)
- Part of a Book (23)
- Conference: Meeting Abstract (19)
- Patent (7)
- Report (5)
- Doctoral Thesis (2)
- Other (2)
- Part of a Periodical (2)
Keywords
- Aachen / Fachhochschule Aachen (3)
- Aachen University of Applied Sciences (3)
- FH Aachen (2)
- Geschichte (2)
- avalanche (2)
- humans (2)
- Adsorbentien (1)
- Cardiovascular MRI (1)
- Cardiovascular Magnetic Resonance (1)
- Commercial Vehicle (1)
Der folgende Bericht fasst Erfahrungen zusammen, die in großen Entwicklungsprojekten der Firma Ericsson über mehrere Jahre gesammelt wurden. Ziel war dabei nicht, agile Methoden und Techniken einzusetzen - Agilität war zu der Zeit noch kein Hype-Thema. Vielmehr wurden Schwächen in den eigenen Projekten identifiziert und verbessert. Der Erfahrungsbericht vergleicht Verbesserungen in diesen Projekten mit den Ansätzen der agilen Entwicklung. Als Ergebnis werden folgende Punkte festgehalten: Erstens, einige Praktiken und Werte der agilen Entwicklung lassen sich auch in Großprojekten einsetzen. Zweitens, bei der Skalierung für Großprojekte werden diese Praktiken langsamer getaktet. Drittens, agile Entwicklung ist nicht nur eine Reihe von Praktiken und Werten, agile Entwicklung ist vielmehr auch eine Frage der Entwicklungs- und Projektkultur. Diese kulturelle Änderung lässt sich in Großprojekten deutlich langsamer umsetzen.
Objective
To investigate whether functional brain networks of epilepsy patients treated with antiepileptic medication differ from networks of healthy controls even during the seizure-free interval.
Methods
We applied different rules to construct binary and weighted networks from EEG and MEG data recorded under a resting-state eyes-open and eyes-closed condition from 21 epilepsy patients and 23 healthy controls. The average shortest path length and the clustering coefficient served as global statistical network characteristics.
Results
Independent on the behavioral condition, epileptic brains exhibited a more regular functional network structure. Similarly, the eyes-closed condition was characterized by a more regular functional network structure in both groups. The amount of network reorganization due to behavioral state changes was similar in both groups. Consistent findings could be achieved for networks derived from EEG but hardly from MEG recordings, and network construction rules had a rather strong impact on our findings.
Conclusions
Despite the locality of the investigated processes epileptic brain networks differ in their global characteristics from non-epileptic brain networks. Further methodological developments are necessary to improve the characterization of disturbed and normal functional networks.
Significance
An increased regularity and a diminished modulation capability appear characteristic of epileptic brain networks.
Durch rapide gesellschaftliche Veränderungen und neue Anforderungen auf dem Arbeitsmarkt gewinnt die akademische berufliche Weiterbildung zunehmend an Bedeutung. Die Nachfrage nach entsprechenden Angeboten ist sowohl seitens der Unternehmen als auch der Arbeitnehmer/-innen hoch. Die Hochschulen sind aufgefordert, darauf zu reagieren und Wege für lebenslanges Lernen aufzuzeigen, indem sie außerhalb der Hochschule erworbene Kenntnisse auf Hochschulabschlüsse anerkennen und Möglichkeiten schaffen, diese Kenntnisse mit dem Ziel weiterzuentwickeln, einen akademischen Abschluss zu erreichen. Dieser Beitrag stellt einen Studiengang vor, der es Berufstätigen ermöglicht, durch die Anrechnung beruflich erworbener Kompetenzen bis zu 50 Prozent der zu erbringenden Studienleistung abzugelten.
A novel scheme for precise diagnostics and effective stabilization of currents in a fuel cell stack
(2010)
A novel scheme for detecting inhomogeneous internal currents in a fuel cell stack is presented. In this paper the scheme is investigated for the case that the flow field plates consist of graphite. Then plates of high conductivity, e.g. aluminium between the flow field plates together with small slits in these plates have three effects: (a) Whenever a local inhomogeneity of the electric current occurs at a particular cell in the stack, this will induce a surface current close to that cell perpendicular to the averaged current. This current can be detected. (b) The plates of high conductivity completely prevent the inhomogeneities from spreading to neighbouring cells. (c) Even at the particular cell the inhomogeneity is suppressed as far as possible. Thus this scheme leads to much better diagnostic possibilities and at the same time reduces electric instabilities to an extent, where they probably become harmless. This scheme will first be explained for a simple model to clarify the idea. However, very precise three dimensional computations using realistic parameters are presented, corroborating the results of the simple model.
A novel tomographic scheme for analysing the state of any single membrane electrode assembly (MEA) in a stack is suggested. Plates of very high conductivity placed between every fuel cell and slitted in an appropriate manner cause surface currents at well-defined locations of the stack. We show that knowing these surface currents, information about anomalies of the currents in a MEA can be obtained using the methods of tomography. The results are mathematically not unique. However, when assuming plausible defect structures, one can exclude improbable deficiencies by applying a special form of simulated annealing. We present numerical calculations of typical examples demonstrating that the essential defects of the MEA in any single cell of the stack can be detected and their extent can be determined.
Unter Energieeffizienz wird verstanden, dass ein definiertes Ziel mit möglichst wenig Energie erreicht wird. Im Beitrag wird zunächst eine Formel zur Berechnung der Gesamtenergieeffizienz eines Gebäudes angegeben. Darauf aufbauend wird ein 3-Säulen-Modell zur Energieeinsparung vorgeschlagen. Es beinhaltet vereinfachte Verfahren zur Berechnung der Betriebseigenschaften von Heizanlagen, raumlufttechnischen Anlagen und Kühl- und Kaltwasseranlagen. Am Beispiel einer RLT-Anlage wird die Vorgehensweise der Bewertung näher erläutert. Zusammenfassend wird festgestellt, dass das vereinfachte Verfahren eine schnelle und sichere energetische Bewertung der genannten Anlagen erlaubt,, zu Präsenzwissen führt, die Haupteinflussgrößen aufzeigt und eine Anlagenbewertung ohne Gebäudebewertung gewährleistet. Das vereinfachte Verfahren wird im Frühjahr 2011 verfügbar sein. Es soll Bestandteil der DIN V 18599 werden, und die EnEV 2012 soll darauf Bezug nehmen.
Normative Regulations
(2010)
Following the success of PET/CT during the last decade and the recent increasing proliferation of SPECT/CT, another hybrid imaging instrument has been gaining more and more interest: MR-PET. First combined, simultaneous PET and MR studies carried out in small animals demonstrated the feasibility of the new approach. Concurrently, some prototypes of an MR-PET scanner for simultaneous human brain studies have been built, their performance is being tested and preliminary applications have already been shown. Through this pioneering work, it has become clear that advances in the detector design are necessary for further optimization.
Recently, the different issues related to the present state and future prospects of MR-PET were presented and discussed during an international 2-day workshop at the Forschungszentrum Jülich, Germany, held after, and in conjunction with, the 2008 IEEE Nuclear Science Symposium and Medical Imaging Conference in Dresden, Germany on October 27–28, 2008. The topics ranged from small animal MR-PET imaging to human MR-BrainPET imaging, new detector developments, challenges/opportunities for ultra-high field MR-PET imaging and considerations of possible future research and clinical applications. This report presents a critical summary of the contributions made to the workshop.