Refine
Year of publication
- 2010 (343) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (73)
- Fachbereich Wirtschaftswissenschaften (41)
- IfB - Institut für Bioengineering (40)
- Fachbereich Elektrotechnik und Informationstechnik (36)
- Fachbereich Chemie und Biotechnologie (35)
- Fachbereich Energietechnik (35)
- Fachbereich Maschinenbau und Mechatronik (31)
- Fachbereich Bauingenieurwesen (24)
- Fachbereich Luft- und Raumfahrttechnik (24)
- INB - Institut für Nano- und Biotechnologien (23)
Language
- English (187)
- German (153)
- Italian (2)
- Multiple languages (1)
Document Type
- Article (140)
- Conference Proceeding (100)
- Book (38)
- Part of a Book (23)
- Conference: Meeting Abstract (20)
- Patent (7)
- Report (5)
- Doctoral Thesis (2)
- Other (2)
- Part of a Periodical (2)
Keywords
- Aachen / Fachhochschule Aachen (3)
- Aachen University of Applied Sciences (3)
- FH Aachen (2)
- Geschichte (2)
- avalanche (2)
- humans (2)
- Adsorbentien (1)
- Cardiovascular MRI (1)
- Cardiovascular Magnetic Resonance (1)
- Commercial Vehicle (1)
75 Jahre Vereinsgeschichte
(2010)
Von der Königlichen Höheren Maschinenbauschule Aachen zu den Ingenieurfachbereichen der FH Aachen
(2010)
The determination of spacing, edge and end distance requirements for self-tapping screws requires numerous and comprehensive insertion tests. Yet the results of such tests cannot be transferred to other types of screws or even to screws of different diameter because of differences in shape or geometry. To reduce the effort of insertion tests a new method was developed which allows the estimation of required spacings, distances and timber thickness.
Differential modulation of valence and arousal in high-alexithymic and low-alexithymic individuals
(2010)
High-alexithymic individuals are characterized by an impaired ability to identify and communicate emotions whereas low-alexithymic individuals have a wide-ranging ability to deal with emotions. This study examined the hypothesis that valence and arousal modifications of emotional stimuli differentially modulate cortical regions in high-alexithymic and low-alexithymic individuals. To this end, 28 high-alexithymic and 25 low-alexithymic individuals were investigated with event-related fMRI using visual emotional stimuli. We found differential neural activations in the dorsal anterior cingulate, the insula and the amygdala. We suggest that these differences may account for the impaired ability of high-alexithymic individuals to appropriately handle emotional stimuli.
Background: One of the most prominent neurobiological models of alexithymia assumes an altered function of the anterior cingulate cortex (ACC) as the crucial neural correlate of alexithymia. So far functional imaging studies have yielded inconclusive results. Therefore, we tested this hypothesis in healthy alexithymics and nonalexithymics in an event-related fMRI study.
Methods: Thirty high- and 30 low-alexithymic right-handed male subjects (selected by the 20-item Toronto Alexithymia Scale, TAS-20) were investigated with event-related fMRI using a picture viewing paradigm. The stimuli consisted of happy, fearful and neutral facial expressions (Ekman-Friesen) as well as positive, negative and neutral pictures from the International Affective Picture System.
Results: Contrasting the high-alexithymic with the low-alexithymic group we observed increased activation of the supragenual ACC for different emotional valences as well as for different emotional stimuli. Moreover, there was a positive correlation of the ACC with the individual TAS-20 scores but no correlations with the individual Beck Depression Inventory scores. Additionally, there was no difference in activity of the amygdala.
Conclusions: We demonstrated that the supragenual ACC is constantly activated more strongly in alexithymic subjects and that this activation is related to the symptoms of alexithymia and not to associated symptoms such as depression. Therefore, our findings support the hypothesis of an altered function of the ACC in alexithymia.
Following the success of PET/CT during the last decade and the recent increasing proliferation of SPECT/CT, another hybrid imaging instrument has been gaining more and more interest: MR-PET. First combined, simultaneous PET and MR studies carried out in small animals demonstrated the feasibility of the new approach. Concurrently, some prototypes of an MR-PET scanner for simultaneous human brain studies have been built, their performance is being tested and preliminary applications have already been shown. Through this pioneering work, it has become clear that advances in the detector design are necessary for further optimization.
Recently, the different issues related to the present state and future prospects of MR-PET were presented and discussed during an international 2-day workshop at the Forschungszentrum Jülich, Germany, held after, and in conjunction with, the 2008 IEEE Nuclear Science Symposium and Medical Imaging Conference in Dresden, Germany on October 27–28, 2008. The topics ranged from small animal MR-PET imaging to human MR-BrainPET imaging, new detector developments, challenges/opportunities for ultra-high field MR-PET imaging and considerations of possible future research and clinical applications. This report presents a critical summary of the contributions made to the workshop.
Design and initial performance of PlanTIS: a high-resolution positron emission tomograph for plants
(2010)
Positron emitters such as 11C, 13N and 18F and their labelled compounds are widely used in clinical diagnosis and animal studies, but can also be used to study metabolic and physiological functions in plants dynamically and in vivo. A very particular tracer molecule is 11CO2 since it can be applied to a leaf as a gas. We have developed a Plant Tomographic Imaging System (PlanTIS), a high-resolution PET scanner for plant studies. Detectors, front-end electronics and data acquisition architecture of the scanner are based on the ClearPET™ system. The detectors consist of LSO and LuYAP crystals in phoswich configuration which are coupled to position-sensitive photomultiplier tubes. Signals are continuously sampled by free running ADCs, and data are stored in a list mode format. The detectors are arranged in a horizontal plane to allow the plants to be measured in the natural upright position. Two groups of four detector modules stand face-to-face and rotate around the field-of-view. This special system geometry requires dedicated image reconstruction and normalization procedures. We present the initial performance of the detector system and first phantom and plant measurements.
Numerical avalanche dynamics models have become an essential part of snow engineering. Coupled with field observations and historical records, they are especially helpful in understanding avalanche flow in complex terrain. However, their application poses several new challenges to avalanche engineers. A detailed understanding of the avalanche phenomena is required to construct hazard scenarios which involve the careful specification of initial conditions (release zone location and dimensions) and definition of appropriate friction parameters. The interpretation of simulation results requires an understanding of the numerical solution schemes and easy to use visualization tools. We discuss these problems by presenting the computer model RAMMS, which was specially designed by the SLF as a practical tool for avalanche engineers. RAMMS solves the depth-averaged equations governing avalanche flow with accurate second-order numerical solution schemes. The model allows the specification of multiple release zones in three-dimensional terrain. Snow cover entrainment is considered. Furthermore, two different flow rheologies can be applied: the standard Voellmy–Salm (VS) approach or a random kinetic energy (RKE) model, which accounts for the random motion and inelastic interaction between snow granules. We present the governing differential equations, highlight some of the input and output features of RAMMS and then apply the models with entrainment to simulate two well-documented avalanche events recorded at the Vallée de la Sionne test site.
Two- and three-dimensional avalanche dynamics models are being increasingly used in hazard-mitigation studies. These models can provide improved and more accurate results for hazard mapping than the simple one-dimensional models presently used in practice. However, two- and three-dimensional models generate an extensive amount of output data, making the interpretation of simulation results more difficult. To perform a simulation in three-dimensional terrain, numerical models require a digital elevation model, specification of avalanche release areas (spatial extent and volume), selection of solution methods, finding an adequate calculation resolution and, finally, the choice of friction parameters. In this paper, the importance and difficulty of correctly setting up and analysing the results of a numerical avalanche dynamics simulation is discussed. We apply the two-dimensional simulation program RAMMS to the 1968 extreme avalanche event In den Arelen. We show the effect of model input variations on simulation results and the dangers and complexities in their interpretation.
Sisyphus wird Steiff
(2010)
Numerical solution of the heat equation with non-linear, time derivative-dependent source term
(2010)
The mathematical modeling of heat conduction with adsorption effects in coated metal structures yields the heat equation with piecewise smooth coefficients and a new kind of source term. This term is special, because it is non-linear and furthermore depends on a time derivative. In our approach we reformulated this as a new problem for the usual heat equation, without source term but with a new non-linear coefficient. We gave an existence and uniqueness proof for the weak solution of the reformulated problem. To obtain a numerical solution, we developed a semi-implicit and a fully implicit finite volume method. We compared these two methods theoretically as well as numerically. Finally, as practical application, we simulated the heat conduction in coated aluminum fibers with adsorption in the zeolite coating. Copyright © 2010 John Wiley & Sons, Ltd.
The CellDrum technology (The term 'CellDrum technology' includes a couple of slightly different technological setups for measuring lateral mechanical tension in various types of cell monolayers or 3D-tissue constructs) was designed to quantify the contraction rate and mechanical tension of self-exciting cardiac myocytes. Cells were grown either within flexible, circular collagen gels or as monolayer on top of respective 1-mum thin silicone membranes. Membrane and cells were bulged outwards by air pressure. This biaxial strain distribution is rather similar the beating, blood-filled heart. The setup allowed presetting the mechanical residual stress level externally by adjusting the centre deflection, thus, mimicking hypertension in vitro. Tension was measured as oscillating differential pressure change between chamber and environment. A 0.5-mm thick collagen-cardiac myocyte tissue construct induced after 2 days of culturing (initial cell density 2 x 10(4) cells/ml), a mechanical tension of 1.62 +/- 0.17 microN/mm(2). Mechanical load is an important growth regulator in the developing heart, and the orientation and alignment of cardiomyocytes is stress sensitive. Therefore, it was necessary to develop the CellDrum technology with its biaxial stress-strain distribution and defined mechanical boundary conditions. Cells were exposed to strain in two directions, radially and circumferentially, which is similar to biaxial loading in real heart tissues. Thus, from a biomechanical point of view, the system is preferable to previous setups based on uniaxial stretching.
The present article describes a standard instrument for the continuous online determination of retinal vessel diameters, the commercially available retinal vessel analyzer. This report is intended to provide informed guidelines for measuring ocular blood flow with this system. The report describes the principles underlying the method and the instruments currently available, and discusses clinical protocol and the specific parameters measured by the system. Unresolved questions and the possible limitations of the technique are also discussed.
Patients after coarctation repair still have an increased risk of cardiovascular or cerebrovascular events. This has been explained by the persisting hypertension and alterations in the peripheral vessels. However, involvement of the central vessels such as the retinal arteries is virtually unknown. A total of 34 patients after coarctation repair (22 men and 12 women; 23 to 58 years old, age range 0 to 32 years at surgical repair) and 34 nonhypertensive controls underwent structural and functional retinal vessel analysis. Using structural analysis, the vessel diameters were measured. Using functional analysis, the endothelium-dependent vessel dilation in response to flicker light stimulation was assessed. In the patients after coarctation repair, the retinal arteriolar diameter was significantly reduced compared to that of the controls (median 182 μm, first to third quartile 171 to 197; vs 197 μm, first to third quartile 193 to 206; p <0.001). These findings were independent of the peripheral blood pressure and age at intervention. No differences were found for venules. The functional analysis findings were not different between the patients and controls (maximum dilation 3.5%, first to third quartile 2.1% to 4.5% vs 3.6%, first to third quartile 2.2% to 4.3%; p = 0.81), indicating preserved autoregulative mechanisms. In conclusion, the retinal artery diameter is reduced in patients after coarctation repair, independent of their current blood pressure level and age at intervention. As a structural marker of chronic vessel damage associated with past, current, or future hypertension, retinal arteriolar narrowing has been linked to stroke incidence. These results indicate an involvement of cerebral microcirculation in aortic coarctation, despite timely repair, and might contribute to explain the increased rate of cerebrovascular events in such patients.
Ein 34-jähriger männlicher Patient stellte sich zur Abklärung einer seit dem 9. Lebensjahr bestehenden und im letzten Jahr rasch progredienten Visusminderung beider Augen bei uns vor. Er beschrieb eine subjektiv zunehmende, im Spiegel für ihn selbst sichtbare, weißliche Trübung in der Pupille beidseits und eine starke Blendempfindlichkeit. Nebenbefundlich gab er rezidivierende Konjunktivitiden und morgens verklebte Lider an. Eine Allergie auf Gräserpollen und eine Unverträglichkeit auf Alkohol sowie mehrere Lebensmittel seien ebenfalls bekannt.
Zusätzlich leidet der Patient an stark ausgeprägtem atopischem Ekzem. Dieses wurde nie systemisch, sondern nur bei Bedarf mit kortisonhaltiger Salbe therapiert.
Bilaterale stromale Hornhauttrübungen sind für den Augenarzt eine differenzialdiagnostische Herausforderung. Im folgenden Beitrag werden 2 Patieninnen (30 und 36 Jahre) mit unterschiedlich stark ausgeprägter stromaler diffuser Hornhauttrübung vorgestellt. Patientin 1 war kleinwüchsig (114 cm) und Patientin 2 normal groß (172 cm). Beide Patientinnen wiesen veränderte Gelenkstrukturen an Hand und Fußgelenken sowie diffuse stromale Hornhauttrübungen auf. Des Weiteren lagen eine Mitral- und Aorteninsuffizienz (Patientin 1) bzw. eine Aorteninsuffizienz (Patientin 2) vor. Die stromalen diffusen Hornhauttrübungen ließen im Zusammenhang mit den Gelenkveränderungen ein Scheie-Syndrom vermuten. Therapeutisch ist bei Patienten mit Visusminderung eine (lamelläre) Keratoplastik sinnvoll.
Purpose: Image analysis by the retinal vessel analyzer (RVA) observes retinal vessels in their dynamic state online noninvasively along a chosen vessel segment. It has been found that high-frequency diameter changes in the retinal artery blood column along the vessel increase significantly in anamnestically healthy volunteers with increasing age and in patients with glaucoma during vascular dilation. This study was undertaken to investigate whether longitudinal sections of the retinal artery blood column are altered in systemic hypertension.
Methods: Retinal arteries of 15 untreated patients with essential arterial hypertension (age, 50.9 ± 11.9 years) and of 15 age-matched anamnestically healthy volunteers were examined by RVA. After baseline assessment, a monochromatic luminance flicker (530–600 nm; 12.5 Hz; 20 s) was applied to evoke retinal vasodilation. Differences in amplitude and frequency of spatial artery blood column diameter change along segments (longitudinal arterial profiles) of 1 mm in length were measured and analyzed using Fourier transformation.
Results: In the control group, average reduced power spectra (ARPS) of longitudinal arterial profiles did not differ when arteries changed from constriction to dilation. In the systemic hypertension group, ARPS during constriction, baseline, and restoration were identical and differed from ARPS during dilation (P < 0.05). Longitudinal arterial profiles in both groups showed significant dissimilitude at baseline and restoration (P < 0.05).
Conclusions: The retinal artery blood column demonstrates microstructural alterations in systemic hypertension and is less irregular along the vessel axis during vessel dilation. These microstructural changes may be an indication of alterations in vessel wall rigidity, vascular endothelial function, and smooth muscle cells in this disease, leading to impaired perfusion and regulation.
formine 2010 ... ein Haus ... : Workshop ; Fachbereich Architektur / Tünnemann, Thomas [Red.]
(2010)
During the development process of a complex technical product, one widely used and important technique is accelerated testing where the applied stress on a component is chosen to exceed the reference stress, i.e. the stress encountered in field operation, in order to reduce the time to failure. For that, the reference stress has to be known. Since a complex technical product may fail regarding numerous failure modes, stress in general is highly dimensional rather than scalar. In addition, customers use their products individually, i.e. field operation should be described by a distribution rather than by one scalar stress value. In this paper, a way to span the customer usage space is shown. It allows the identification of worst case reference stress profiles in significantly reduced dimensions with minimal loss of information. The application example shows that even for a complex product like a combustion engine, stress information can be compressed significantly. With low measurement effort it turned out that only three reference stress cycles were sufficient to cover a broad range of customer stress variety.
With the final objective of optimizing the "Micromix" hydrogen combustion principle, a round jet in a laminar cross-flow prior to its combustion is investigated experimentally using Stereoscopic Particle Image Velocimetry. Measurements are performed at a jet to cross-stream momentum ratio of 1 and a Reynolds number, based on the jet diameter and jet velocity, of 1600. The suitability to combine side, top and end views is analyzed statistically. The statistical theory of testing hypotheses, pertaining to the joint distribution of the averaged velocity along intersecting observation planes, is employed. Overall, the averaged velocity fields of the varying observation planes feature homogeneity at a 0.05 significance level. Minor discrepancies are related to the given experimental conditions. By use of image maps, averaged and instantaneous velocity fields, an attempt is made to elucidate the flow physics and a kinematically consistent vortex model is proposed. In the time-averaged flow field, the principal vortical systems were identified and the associated mixing visualized. The jet trajectory and physical dimensions scale with the momentum ratio times the jet diameter. The jet/cross-flow mixture converging upon the span-wise centre-line, the lifting action of the Counter Rotating Vortex Pair and the reversed flow region contribute to the high entrainment and mixedness. It is shown that the jet width is larger on the downstream side as compared to the upstream side of the centre-streamline. The deepest penetration of the particles on the outer boundary occurs in the centre-plane. Meanwhile, with increasing off-centre position, the boundaries all lay further from the centre-line position than does the boundary in the centre-plane, corresponding to a kidney-like shape of the flow cross-section. The generation of the Counter Rotating Vortex Pair and the instability mechanism is documented by instantaneous image maps and vector fields. The necessary circulation for the Counter Rotating Vortex Pair originates from a combined effect of steady in-hole, hanging and wake vortices. The strong cross-flow and jet interaction induces a three-dimensional waving, the stream-wise Counter Rotating Vortex Pair pair, leading to the formation of Ring Like Vortices. A secondary Counter Rotating Vortex Pair forms on top of the primary Counter Rotating Vortex Pair, resulting in mixing by "puffs". Overall, Stereoscopic Particle Image Velocimetry proofed capable of elucidating the Jet in Cross-Flow complex flow field. The gained insight in the mixing process will definitely contribute to the "Micromix" hydrogen combustion optimization.
For more than a decade up to now there is an ongoing interest in small gas turbines downsized to micro-scale. With their high energy density they offer a great potential as a substitute for today’s unwieldy accumulators, found in a variety of applications like laptops, small tools etc. But micro-scale gas turbines could not only be used for generating electricity, they could also produce thrust for powering small unmanned aerial vehicles (UAVs) or similar devices. Beneath all the great design challenges with the rotating parts of the turbomachinery at this small scale, another crucial item is in fact the combustion chamber needed for a safe and reliable operation. With the so called regular micromix burning principle for hydrogen successfully downscaled in an initial combustion chamber prototype of 10 kW energy output, this paper describes a new design attempt aimed at the integration possibilities in a μ-scale gas turbine. For manufacturing the combustion chamber completely out of stainless steel components, a recuperative wall cooling was introduced to keep the temperatures in an acceptable range. Also a new way of an integrated ignition was developed. The detailed description of the prototype’s design is followed by an in depth report about the test results. The experimental investigations comprise a set of mass flow variations, coupled with a variation of the equivalence ratio for each mass flow at different inlet temperatures and pressures. With the data obtained by an exhaust gas analysis, a full characterisation concerning combustion efficiency and stability of the prototype chamber is possible. Furthermore the data show a full compliance with the expected operating requirements of the designated μ-scale gas turbine.
Among many approaches to address the high-level decision making problem for autonomous robots and agents, the robot program¬ming and plan language Golog follows a logic-based deliberative approach, and its successors were successfully deployed in a number of robotics applications over the past ten years. Usually, Golog interpreter are implemented in Prolog, which is not available for our target plat¬form, the bi-ped robot platform Nao. In this paper we sketch our first approach towards a prototype implementation of a Golog interpreter in the scripting language Lua. With the example of the elevator domain we discuss how the basic action theory is specified and how we implemented fluent regression in Lua. One possible advantage of the availability of a Non-Prolog implementation of Golog could be that Golog becomes avail¬able on a larger number of platforms, and also becomes more attractive for roboticists outside the Cognitive Robotics community.
In order to allow an autonomous robot to perform non-trivial tasks like to explore a foreign planet the robot has to have deliberative capabilities like reasoning or planning. Logic-based approaches like the programming and planing language Golog and it successors has been successfully used for such decision-making problems. A drawback of this particular programing language is that their interpreter usually are written in Prolog and run on a Prolog back-end. Such back-ends are usually not available or feasible on resource-limited robot systems. In this paper we present our ideas and first results of a re-implementation of the interpreter based on the Lua scripting language which is available on a wide range of systems including small embedded systems.
We propose a formalism for reasoning about actions based on multi-modal logic which allows for expressing observations as first-class objects. We introduce a new modal operator, namely [o |α], which allows us to capture the notion of perceiving an observation given that an action has taken place. Formulae of the type [o |α]ϕ mean ’after perceiving observation o, given α was performed, necessarily ϕ’. In this paper, we focus on the challenges concerning sensing with explicit observations, and acting with nondeterministic effects. We present the syntax and semantics, and a correct and decidable tableau calculus for the logic
In this extended abstract we describe the robot programming and planning language READYLOG, a GOLOG dialect which was developed to support the decision making of robots acting in dynamic real-time domains like robotic soccer. The formal framework of READYLOG, which is based on the situation calculus, features imperative control structures like loops and procedures, allows for decision-theoretic planning, and accounts for a continuously changing world. We developed high-level controllers in READYLOG for our soccer robots in RoboCup’s Middle-size league, but also for service robots and for autonomous agents in interactive computer games.
The idea of component-based software engineering was proposed more that 40 years ago, yet only few robotics software frameworks follow these ideas. The main problem with robotics software usually is that it runs on a particular platform and transferring source code to another platform is crucial. In this paper, we present our software framework Fawkes which follows the component-based software design paradigm by featuring a clear component concept with well-defined communication interfaces. We deployed Fawkes on several different robot platforms ranging from service robots to biped soccer robots. Following the component concept with clearly defined communication interfaces shows great benefit when porting robot software from one robot to the other. Fawkes comes with a number of useful plugins for tasks like timing, logging, data visualization, software configuration, and even high-level decision making. These make it particularly easy to create and to debug productive code, shortening the typical development cycle for robot software.
The high-level decision making process of an autonomous robot can be seen as an hierarchically organised entity, where strategical decisions are made on the topmost layer, while the bottom layer serves as driver for the hardware. In between is a layer with monitoring and reporting functionality. In this paper we propose a behaviour engine for this middle layer which, based on formalism of hybrid state machines (HSMs), bridges the gap between high-level strategic decision making and low-level actuator control. The behaviour engine has to execute and monitor behaviours and reports status information back to the higher level. To be able to call the behaviours or skills hierarchically, we extend the model of HSMs with dependencies and sub-skills. These Skill-HSMs are implemented in the lightweight but expressive Lua scripting language which is well-suited to implement the behaviour engine on our target platform, the humanoid robot Nao.
Hybrid control for autonomous systems — Integrating learning, deliberation and reactive control
(2010)
Autonomous robotic systems for penetrating thick ice shells with simultaneous collecting of scientific data are very promising devices in both terrestrial (glacier, climate research) and extra-terrestrial applications. Technical challenges in development of such systems are numerous and include 3D-navigation, an appropriate energy source, motion control, etc. Not less important is the problem of forward contamination of the pristine glacial environments with microorganisms and biomolecules from the surface of the probe. This study was devoted to establishing a laboratory model for microbial contamination of a newly constructed ice-melting probe called IceMole and to analyse the viability and amount of the contaminating microorganisms as a function of distance. The used bacterial strains were Bacillus subtilis (ATCC 6051) and Escherichia coli (ATCC 11775). The main objective was development of an efficient and reliable in-situ decontamination method of the melting probe. Therefore, several chemical substances were tested in respect of their efficacy to eliminate bacteria on the surface of the melting probe at low temperature (0 - 5 °C) and at continuous dilution by melted water. Our study has shown that at least 99.9% decontamination of the IceMole can be successfully achieved by the injection of 30% (v/v) hydrogen peroxide and 3% (v/v) sodium hypochlorite into the drilling site. We were able to reproduce this result in both time-dependent and depth-dependent experiments. The sufficient amount of 30% (v/v) H₂O₂ or 3% (v/v) NaClO has been found to be approximately 18 L per cm² of the probe’s surface.
Aims: Thrombotic complications due to activation of platelets and plasmatic clotting factors belong still to the most investigated topics in the field of study of patho-physiological mechanisms. Mathematical modeling of thrombotic reactions is established and validated in test cases. Aim of this study is to experimentally evaluate and computationally simulate platelets under the influence of well-defined shear flow conditions. Platelet behaviour and reactions are experimentally reproduced, measured and used for validation of the numerical simulation. Methods: A mathematical model of platelet activation, adhesion and aggregation has been implemented into a finite element CFD (Computational Fluid Dynamics) code. The approach is based on the advective and diffusive transport equations for resting platelets, activated platelets and platelet released agonists. Adhesion rates for the reactive surfaces depend on the hemocompatibility properties of the surface and the local shear rate. Experiments with citrate-anticoagulated freshly-drawn whole blood are performed in a perfusion flow chamber as well as in a system of rotating cylinders for Couette and Taylor-vortex flow. Different biomaterials are used. The activation, drop of platelet concentration, adhesion and aggregation are quantified using scanning electron microscopy (SEM) and flow cytometry. Results: Regions and flow conditions with a high potential for thrombus growth could be identified. The experiments clearly show the influence of the blood contacting material and flow properties. By means of SEM diverse platelet adhesion patterns are observed. Numerical analysis can explain the patterns and the degree of thrombus formation. Conclusion: The numerical method shows good agreement with experimental data indicating a possible prediction of initiation of activation and detection of the local adhesion areas in connection with the role of Von-Willebrand-Factor.
Purpose of Study: Thrombosis-related complications are among the leading causes for morbidity and mortality in patients who depend on artificial organs. For the prediction of platelet behavior both the flow conditions inside the device and the thrombogenic properties of the blood-contacting surfaces must be considered. Platelet reactions under the influence of well-defined shear rates are experimentally evaluated and numerically simulated. The approach is intended for the analysis of VAD and oxygenator design.
Methods Used: A mathematical model of platelet activation, adhesion and aggregation has been implemented into a finite element CFD (Computational Fluid Dynamics) code. The approach is based on the advective and diffusive transport equations for resting and activated platelets and platelet released agonists. Experiments with citrate-anticoagulated freshly-drawn whole blood are performed in a perfusion flow chamber as well as in a system of rotating cylinders for Couette and Taylor-vortex flow. Different biomaterials are used. The activation, adhesion and aggregation are quantified using scanning electron microscopy and flow cytometry.
Summary of Results: Regions and flow conditions with a high potential for thrombus growth could be identified. The experiments clearly show the influence of the blood contacting material and governing shear rates. Numerical analysis can explain observed adhesion patterns and the degree of thrombus formation
The MicroMed DeBakey ventricular assist device is an axial flow pump designed for providing long-term support to end-stage heartfailure patients. Previously, we presented computational analysis of the blood pump flow. From the analysis, we were able to identify regions of high shear and recirculating flow that may cause blood damage, for example, deformation and fragmentation of the red blood cell (RBC). This mechanical hemolysis can be predicted using a tensor-based blood damage model that is based on the physical properties of the RBCs, for example, the relaxation time of the RBC membrane. However, an extensive and detailed analysis was complicated by the fact that the previous method predicts hemolysis along a finite number of pathlines traversed by the RBCs, possibly omitting parts of the flow domain. Furthermore, it is computationally expensive and is not easily parallelizable.
Here, we propose a new method to estimate hemolysis. The method is based on treating the shape of droplet (tensor) as a field variable, like velocity in the Navier-Stokes system. The governing equation for the RBC shape is treated by least-squares finite element method and the volume conservation of the RBC is augmented by Lagrangian multiplier. Unlike the previous method, the proposed method can visualize areas of high RBC strain that is potentially dangerous for mechanical hemolysis. Also, the amount of plasma-free hemoglobin and, consequently, normalized index of hemolysis can be computed as a byproduct. The method is tested in a simple shear flow for validation and an artery graft flow is chosen to show its potential usefulness. Finally, the method is applied to the blood damage estimation for the pump.