Refine
Year of publication
- 2013 (138) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (48)
- INB - Institut für Nano- und Biotechnologien (32)
- Fachbereich Chemie und Biotechnologie (24)
- IfB - Institut für Bioengineering (20)
- Fachbereich Wirtschaftswissenschaften (18)
- Fachbereich Elektrotechnik und Informationstechnik (13)
- Fachbereich Energietechnik (12)
- Sonstiges (6)
- Fachbereich Luft- und Raumfahrttechnik (5)
- Fachbereich Bauingenieurwesen (4)
Has Fulltext
- no (138) (remove)
Document Type
- Article (138) (remove)
Keywords
The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the spatial distribution of specific ions on the sensing surface. The conventional chemical imaging system based on the light-addressable potentiometric sensor (LAPS), however, required a long time to obtain a chemical image, due to the slow mechanical scan of a single light beam. For high-speed imaging, a plurality of light beams modulated at different frequencies can be employed to measure the ion concentrations simultaneously at different locations on the sensor plate by frequency division multiplex (FDM). However, the conventional measurement geometry of back-side illumination limited the bandwidth of the modulation frequency required for FDM measurement, because of the low-pass filtering characteristics of carrier diffusion in the Si substrate. In this study, a high-speed chemical imaging system based on front-side-illuminated LAPS was developed, which achieved high-speed spatiotemporal recording of pH change at a rate of 70 frames per second.
Mass transfer correlation for evaporation–condensation thermal process in the range of 70 °C–95 °C
(2013)
Latente Steuern im Zusammenhang mit Beteiligungen an Tochterunternehmen im IFRS-Konzernabschluss
(2013)
Modeling contribution to risk assessment of thermal production power for geothermal reservoirs
(2013)
A High-Throughput Functional Complementation Assay for Classification of BRCA1 Missense Variants
(2013)
Obesity-induced overexpression of miR-802 impairs glucose metabolism through silencing of Hnf1b
(2013)
Size unlimited markerless deletions by a transconjugative plasmid-system in Bacillus licheniformis
(2013)
The concept of an injective affine embedding of the quantum states into a set of classical states, i.e., into the set of the probability measures on some measurable space, as well as its relation to statistically complete observables is revisited, and its limitation in view of a classical reformulation of the statistical scheme of quantum mechanics is discussed. In particular, on the basis of a theorem concerning a non-denseness property of a set of coexistent effects, it is shown that an injective classical embedding of the quantum states cannot be supplemented by an at least approximate classical description of the quantum mechanical effects. As an alternative approach, the concept of quasi-probability representations of quantum mechanics is considered.
In modernen Fahrzeugkarosserien der Großserie kommen zunehmend Materialmischbauweisen
zur Anwendung. In Zusammenarbeit der Daimler AG, der Tower Automotive Holding
GmbH, der Imperia GmbH sowie der Partnerunternehmen KSM Castings GmbH und Schaufler
Tooling GmbH & Co. KG wird das Leichtbaupotenzial von Stahlblech-AluminiumverbundgussHybriden
am Beispiel des vorderen Dachquerträgers des Mercedes-Benz Viano/Vito ausführlich
untersucht.
In modernen Fahrzeugkarosserien der Großserie kommen zunehmend Materialmischbauweisen zur Anwendung. In Zusammenarbeit der Daimler AG, der Tower Automotive Holding GmbH, der Imperia GmbH sowie der Partnerunternehmen KSM Castings GmbH und Schaufler Tooling GmbH & Co. KG wird das Leichtbaupotenzial von Aluminiumverbundguss-Stahlblech-Hybriden am Beispiel des vorderen Dachquerträgers des Mercedes-Benz Viano/Vito ausführlich untersucht.