Refine
Year of publication
- 2017 (109) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (45)
- INB - Institut für Nano- und Biotechnologien (24)
- IfB - Institut für Bioengineering (14)
- Fachbereich Chemie und Biotechnologie (11)
- Fachbereich Maschinenbau und Mechatronik (11)
- Fachbereich Wirtschaftswissenschaften (10)
- Fachbereich Bauingenieurwesen (9)
- Fachbereich Luft- und Raumfahrttechnik (9)
- Fachbereich Elektrotechnik und Informationstechnik (8)
- Fachbereich Energietechnik (7)
Has Fulltext
- no (109)
Document Type
- Article (109) (remove)
Keywords
- 3D nonlinear finite element model (1)
- CNOT (1)
- Capacitive field-effect (1)
- Chemical images (1)
- Chemical sensor (1)
- Dehydrogenase (1)
- Diaphorase (1)
- Dry-low-NOx (DLN) combustion (1)
- EIS capacitive sensor (1)
- Effective modal mass (1)
Is part of the Bibliography
- no (109)
The Pharmacokinetics and Metabolism of Lumiracoxib in Chimeric Humanized and Murinized FRG Mice
(2017)
Reinigungsprozesse in der Lebensmittelindustrie. Entwicklung eines Demonstrators zur Überwachung
(2017)
Development and Testing of a Low NOX Micromix Combustion Chamber for an Industrial Gas Turbine
(2017)
The Micromix combustion principle, based on cross-flow mixing of air and hydrogen, promises low emission applications in future gas turbines. The Micromix combustion takes place in several hundreds of miniaturized diffusion-type micro-flames. The major advantage is the inherent safety against flash-back and low NOx-emissions due to a very short residence time of reactants in the flame region. The paper gives insight into the Micromix design and scaling procedure for different energy densities and the interaction of scaling laws and key design drivers in gas turbine integration. Numerical studies, experimental testing, gas turbine integration and interface considerations are evaluated. The aerodynamic stabilization of the miniaturized flamelets and the resulting flow field, flame structure and NOx formation are analysed experimentally and numerically. The results show and confirm the successful adaption of the low NOx Micromix characteristics for a range of different nozzle sizes, energy densities and thermal power output.
Für Auftragschweißaufgaben existiert eine Vielzahl an verfahrenstechnischen
Prozessvarianten, die je nach Charakteristik und Anwendungsfall
ausgewählt werden. Ein Nachteil der vorwiegend verwendeten Metall-
Schutzgasschweißprozesse (MSG) für das Auftragschweißen ist durch die
direkte Kopplung von Drahtvorschub zu Energieeintrag gegeben. Die vorgestellte
Zweidraht-Prozessvariante kann durch die Ausbildung eines übertragenen
und eines nicht-übertragenen Lichtbogens die elektrische Leistung
beider Lichtbögen variieren und damit einen direkten Einfluss auf
die Prozessgrößen Abschmelzleistung und Aufschmelzgrad nehmen. Im
Speziellen besteht über die Entkopplung von Drahtvorschub zu Schweißstromstärke
die Möglichkeit eines niederenergetischen Betriebs trotz hoher
Drahtvorschubgeschwindigkeit. Damit lassen sich Aufschmelzgrade
unter 2% umsetzen und Abschmelzleistungen bis zu 15 kg/h realisieren.
Eigene positive Erfahrungen mit Onlinekursen sowie die geringen Studierendenzahlen in der Präsenzlehre gaben den Anstoß zu einem Experiment mit einem offenen Onlinekurs auf der Plattform Udemy. Die Erfahrungen sowohl bei der Erstellung und als auch im Lehrbetrieb waren positiv und führten zu einer neuen Beschäftigung mit Inhalten und Lernenden, getrieben durch die Anforderungen der Lernplattform.
Modulation of muscle-tendon interaction in the human triceps surae during an energy dissipation task
(2017)
Altered neurovascular coupling as measured by optical imaging: a biomarker for Alzheimer’s disease
(2017)
Implikationen der Digitalisierung für den Finanzbereich der Unternehmung und das Rollenbild des CFO
(2017)
The immobilization of NAD+-dependent dehydrogenases, in combination with a diaphorase, enables the facile development of multiparametric sensing devices. In this work, an amperometric biosensor array for simultaneous determination of ethanol, formate, d- and l-lactate is presented. Enzyme immobilization on platinum thin-film electrodes was realized by chemical cross-linking with glutaraldehyde. The optimization of the sensor performance was investigated with regard to enzyme loading, glutaraldehyde concentration, pH, cofactor concentration and temperature. Under optimal working conditions (potassium phosphate buffer with pH 7.5, 2.5 mmol L-1 NAD+, 2.0 mmol L-1 ferricyanide, 25 °C and 0.4% glutaraldehyde) the linear working range and sensitivity of the four sensor elements was improved. Simultaneous and cross-talk free measurements of four different metabolic parameters were performed successfully. The reliable analytical performance of the biosensor array was demonstrated by application in a clarified sample of inoculum sludge. Thereby, a promising approach for on-site monitoring of fermentation processes is provided.
Three amperometric biosensors have been developed for the detection of L-malic acid, fumaric acid, and L -aspartic acid, all based on the combination of a malate-specific dehydrogenase (MDH, EC 1.1.1.37) and diaphorase (DIA, EC 1.8.1.4). The stepwise expansion of the malate platform with the enzymes fumarate hydratase (FH, EC 4.2.1.2) and aspartate ammonia-lyase (ASPA, EC 4.3.1.1) resulted in multi-enzyme reaction cascades and, thus, augmentation of the substrate spectrum of the sensors. Electrochemical measurements were carried out in presence of the cofactor β-nicotinamide adenine dinucleotide (NAD+) and the redox mediator hexacyanoferrate (III) (HCFIII). The amperometric detection is mediated by oxidation of hexacyanoferrate (II) (HCFII) at an applied potential of + 0.3 V vs. Ag/AgCl. For each biosensor, optimum working conditions were defined by adjustment of cofactor concentrations, buffer pH, and immobilization procedure. Under these improved conditions, amperometric responses were linear up to 3.0 mM for L-malate and fumarate, respectively, with a corresponding sensitivity of 0.7 μA mM−1 (L-malate biosensor) and 0.4 μA mM−1 (fumarate biosensor). The L-aspartate detection system displayed a linear range of 1.0–10.0 mM with a sensitivity of 0.09 μA mM−1. The sensor characteristics suggest that the developed platform provides a promising method for the detection and differentiation of the three substrates.
An enzyme-based reversible Controlled NOT (CNOT) logic gate operating on a semiconductor transducer
(2017)
An enzyme-based biocatalytic system mimicking operation of a logically reversible Controlled NOT (CNOT) gate has been interfaced with semiconductor electronic transducers. Electrolyte–insulator–semiconductor (EIS) structures have been used to transduce chemical changes produced by the enzyme system to an electronically readable capacitive output signal using field-effect features of the EIS device. Two enzymes, urease and esterase, were immobilized on the insulating interface of EIS structure producing local pH changes performing XOR logic operation controlled by various combinations of the input signals represented by urea and ethyl butyrate. Another EIS transducer was functionalized with esterase only, thus performing Identity (ID) logic operation for the ethyl butyrate input. Both semiconductor devices assembled in parallel operated as a logically reversible CNOT gate. The present system, despite its simplicity, demonstrated for the first time logically reversible function of the enzyme system transduced electronically with the semiconductor devices. The biomolecular realization of a CNOT gate interfaced with semiconductors is promising for integration into complex biomolecular networks and future biosensor/biomedical applications.
Die Verbindung der Welten dressierter Elektronen und grenzenloser Kreativität bietet ein großes Potential; zum Beispiel bei modernen Skulpturen, deren Form sich durch Motoren verändern kann. An der FH Aachen wurde ein solches Projekt verwirklicht: Eine Matrix aus Holzkugeln kann Piktogramme anzeigen, aber auch mathematische Funktionen visualisieren. In diesem Artikel beschreiben wir die clevere Ansteuerung der Motoren.