Refine
Year of publication
- 2010 (343) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (73)
- Fachbereich Wirtschaftswissenschaften (41)
- IfB - Institut für Bioengineering (40)
- Fachbereich Elektrotechnik und Informationstechnik (36)
- Fachbereich Chemie und Biotechnologie (35)
- Fachbereich Energietechnik (35)
- Fachbereich Maschinenbau und Mechatronik (31)
- Fachbereich Bauingenieurwesen (24)
- Fachbereich Luft- und Raumfahrttechnik (24)
- INB - Institut für Nano- und Biotechnologien (23)
Language
- English (187)
- German (153)
- Italian (2)
- Multiple languages (1)
Document Type
- Article (140)
- Conference Proceeding (100)
- Book (38)
- Part of a Book (23)
- Conference: Meeting Abstract (20)
- Patent (7)
- Report (5)
- Doctoral Thesis (2)
- Other (2)
- Part of a Periodical (2)
Keywords
- Aachen / Fachhochschule Aachen (3)
- Aachen University of Applied Sciences (3)
- FH Aachen (2)
- Geschichte (2)
- avalanche (2)
- humans (2)
- Adsorbentien (1)
- Cardiovascular MRI (1)
- Cardiovascular Magnetic Resonance (1)
- Commercial Vehicle (1)
Purpose:
MRI plays a leading diagnostic role in assessing the musculoskeletal (MSK) system and is well established for most questions at clinically used field strengths (up to 3 T). However, there are still limitations in imaging early stages of cartilage degeneration, very fine tendons and ligaments, or in locating nerve lesions, for example. 7 T MRI of the knee has already received increasing attention in the current published literature, but there is a strong need to develop new radiofrequency (RF) coils to assess more regions of the MSK system. In this work, an eight-channel transmit/receive RF array was built as a multipurpose coil for imaging some of the thus far neglected regions. An extensive coil characterization protocol and first in vivo results of the human wrist, shoulder, elbow, knee, and ankle imaged at 7 T will be presented.
Methods:
Eight surface loop coils with a dimension ofurn:x-wiley:00942405:media:mp7176:mp7176-math-0001 were machined from FR4 circuit board material. To facilitate easy positioning, two coil clusters, each with four loop elements, were combined to one RF transmit/receive array. An overlapped and shifted arrangement of the coil elements was chosen to reduce the mutual inductance between neighboring coils. A phantom made of body-simulating liquid was used for tuning and matching on the bench. Afterward, the S-parameters were verified on a human wrist, elbow, and shoulder. For safety validation, a detailed compliance test was performed including full wave simulations of the RF field distribution and the corresponding specific absorption rate (SAR) for all joints. In vivo images of four volunteers were assessed with gradient echo and spin echo sequences modified to obtain optimal image contrast, full anatomic coverage, and the highest spatial resolution within a reasonable acquisition time. The performance of the RF coil was additionally evaluated by in vivo B1 mapping.
Results:
A comparison of B1 per unit power, flip angle distribution, and anatomic images showed a fairly homogeneous excitation for the smaller joints (elbow, wrist, and ankle), while for the larger joints, the shoulder and especially the knee, B1 inhomogeneities and limited penetration depth were more pronounced. However, the greater part of the shoulder joint could be imaged.In vivo images rendered very fine anatomic details such as fascicles of the median nerve and the branching of the nerve bundles. High-resolution images of cartilage, labrum, and tendons could be acquired. Additionally, turbo spin echo (TSE) and inversion recovery sequences performed very well.
Conclusions:
This study demonstrates that the concept of two four-channel transmit/receive RF arrays can be used as a multipurpose coil for high-resolutionin vivo MR imaging of the musculoskeletal system at 7 T. Not only gradient echo but also typical clinical and SAR-intensive sequences such as STIR and TSE performed well. Imaging of small structures and peripheral nerves could in particular benefit from this technique.
The control of molecular architecture provided by the layer-by-layer (LbL) technique has led to enhanced biosensors, in which advantageous features of distinct materials can be combined. Full optimization of biosensing performance, however, is only reached if the film morphology is suitable for the principle of detection of a specific biosensor. In this paper, we report a detailed morphology analysis of LbL films made with alternating layers of single-walled carbon nanotubes (SWNTs) and polyamidoamine (PAMAM) dendrimers, which were then covered with a layer of penicillinase (PEN). An optimized performance to detect penicillin G was obtained with 6-bilayer SWNT/PAMAM LbL films deposited on p-Si-SiO2-Ta2O5 chips, used in biosensors based on a capacitive electrolyte-insulator-semiconductor (EIS) and a light-addressable potentiometric sensor (LAPS) structure, respectively. Field-emission scanning electron microscopy (FESEM) and atomic force microscopy (AFM) images indicated that the LbL films were porous, with a large surface area due to interconnection of SWNT into PAMAM layers. This morphology was instrumental for the adsorption of a larger quantity of PEN, with the resulting LbL film being highly stable. The experiments to detect penicillin were performed with constant-capacitance (ConCap) and constant-current (CC) measurements for EIS and LAPS sensors, respectively, which revealed an enhanced detection signal and sensitivity of ca. 100 mV/decade for the field-effect sensors modified with the PAMAM/SWNT LbL film. It is concluded that controlling film morphology is essential for an enhanced performance of biosensors, not only in terms of sensitivity but also stability and response time.
b-Lactame gehören zu den wirkungsvollsten Antibiotika, jedoch lassen sich viele nur schwierig fermentativ erzeugen. Ein Problem bei der fermentativen Produktion ist die Hydrolyse des Lactamrings im wässrigen Milieu. Das Ziel des von der DBU geförderten Projekts ist die selektive In-situ-Adsorption der b-Lactamantibiotika unter anschließender magnetischer Separation. Durch die Isolation im Hochgradientenmagnetseparator (HGMS) ist eine Fest-fest-flüssig-Trennung und somit ein erheblicher Zeitgewinn im Downstreamprozess möglich. Zusätzlich kommt es zur Einsparung an Lösungsmittel und Energie, was neben Reduzierung der Antibiotikahydrolyse auch in ökologischer Hinsicht einen interessanten Aspekt darstellt. Als Trägermaterial für die Adsorbermatrix werden magnetisierbare Eisenoxidpartikel eingesetzt, die in einer Silikamatrix eingebettet sind. Diese Adsorber sollen auf Selektivität in Wasser und verschiedenen Medien getestet werden. Zusätzlich werden die Abbauprodukte des b-Lactams analysiert, um eine Aussage über die Stabilisierung des Antibiotikums durch die selektiven Adsorber treffen zu können. Diese Ergebnisse werden mit kommerziell erhältlichen Adsorbern verglichen. Die Aufreinigung der Antibiotika soll direkt aus der Fermentationsbrühe erfolgen. Um die Trennung der magnetischen, selektiven Adsorber von der Biomasse zu gewährleisten, soll der HGMS in die Fermentation integriert werden. Das filamentöse Wachstum des Mikroorganismus erfordert eine Neuauslegung der Filtermatrix.
Eine SPS im Kraftfahrzeug? Das geht ja gar nicht – da gibt es doch all die Hersteller für Kfz-Steuergeräte, die konfigurierbare Hardware anbieten. Im Prinzip ja, aber leider sind gerade die Sensoren oder Aktoren nicht ansteuerbar, die der Entwickler genau für sein aktuelles Projekt benötigt. Dieser Beitrag gibt einen kleinen Einblick in neue Möglichkeiten des Rapid Prototyping für mechatronische Systeme auf der Basis von Speicherprogrammierbaren Steuerungen (SPS).
Es wurde ein automatisiertes, computerunterstütztes Testsystem für die Funktionsprüfung und Charakterisierung von (bio-)chemischen Sensoren auf Waferebene entwickelt und in einen konventionellen Spitzenmessplatz integriert. Das System ermöglicht die Charakterisierung und Identifizierung „funktionstauglicher“ Sensoren bereits auf Waferebene zwischen den einzelnen Herstellungsschritten, wodurch weitere, bisher übliche Verarbeitungsschritte wie das Fixieren, Bonden und Verkapseln für die defekten oder nicht funktionstauglichen Sensorstrukturen entfällt. Außerdem bietet eine speziell entworfene miniaturisierte Durchflussmesszelle die Möglichkeit, bereits auf Waferlevel die Sensitivität, Drift, Hysterese und Ansprechzeit der (bio-)chemischen Sensoren zu charakterisieren. Das System wurde exemplarisch mit kapazitiven, pH-sensitiven EIS- (Elektrolyt-Isolator-Silizium) Strukturen und ISFET- (ionensensitiver Feldeffekttransistor) Strukturen mit verschiedenen Geometrien und Gate-Layouts getestet.
Two- and three-dimensional avalanche dynamics models are being increasingly used in hazard-mitigation studies. These models can provide improved and more accurate results for hazard mapping than the simple one-dimensional models presently used in practice. However, two- and three-dimensional models generate an extensive amount of output data, making the interpretation of simulation results more difficult. To perform a simulation in three-dimensional terrain, numerical models require a digital elevation model, specification of avalanche release areas (spatial extent and volume), selection of solution methods, finding an adequate calculation resolution and, finally, the choice of friction parameters. In this paper, the importance and difficulty of correctly setting up and analysing the results of a numerical avalanche dynamics simulation is discussed. We apply the two-dimensional simulation program RAMMS to the 1968 extreme avalanche event In den Arelen. We show the effect of model input variations on simulation results and the dangers and complexities in their interpretation.
Die Spritzbetonbauweise hat sich im Tunnelbau seit Jahren bewährt. Spritzbeton wird als unbewehrter Beton, in Verbindung mit Bewehrung sowie als Stahlfaserspritzbeton eingesetzt. Bei den meisten Tunnelschalen aus Stahlfaserspritzbeton werden Stahlfasern derzeit nur als konstruktive Bewehrung verwendet. Die Faserzugabe führt zu einer nennenswerten Erhöhung der Bruchenergie und somit zu einer höheren Zähigkeit des sonst spröden Materials und damit zu einer höheren Sicherheit.
Stahlfaserspritzbeton kann auch anstelle von Spritzbeton mit statisch erforderlicher Mattenbewehrung eingesetzt werden. Die Bemessung erfolgt dann unter Berücksichtigung der Nachrisszugfestigkeit. Diese kann wie bei Stahlfaserbeton an Biegebalken ermittelt werden, die aus größeren Proben herausgesägt werden. Anhand von verschiedenen Beispielen werden die unterschiedlichen Anwendungen aufgezeigt und die dafür erforderlichen Prüfungen vorgestellt.
Beobachtungskommunikation
(2010)
Betriebsratswahlen 2010
(2010)
Die nächsten regelmäßigen Wahlen zum Betriebsrat (BR) stehen vor der Tür. Sie finden in der Zeit vom 1.3.2010 bis 31.5.2010 statt. Die Wahlen sind zwar vornehmlich Sache der Arbeitnehmer, allerdings sollten auch die Arbeitgeber darauf achten, dass die Wahlen korrekt ablaufen, schließlich haben die Arbeitgeber die Kosten der Wahlen zu tragen. Kommt es hierbei zu Fehlern, die schlimmstenfalls eine Wiederholung der Wahlen erfordern, hat auch für die hierdurch zusätzlich entstehenden Kosten der Arbeitgeber aufzukommen. Zudem bietet die aktive und unterstützende Begleitung der Wahlen für die Arbeitgeber die Chance, die Grundlagen für eine konstruktive Zusammenarbeit mit dem künftigen Betriebsrat zu legen. Der vorliegende Beitrag erläutert die wesentlichen Abläufe des Wahlverfahrens sowie die hierbei zwingend zu beachtenden Fristen.
In den letzten drei bis vier Jahren unterlag der Bereich der Bilanzierung und Offenlegung von unsicheren Steuerpositionen im IFRS- und US-GAAP-Abschluss einem stetigen Wandel. Sowohl nach US-GAAP als auch nach IFRS nehmen die Anforderungen an die Bilanzierung und Offenlegung beständig zu. Schon allein dies zeigt die Bedeutung, die dem Themenbereich der Steuerrisiken beigemessen wird. Aber nicht nur im Rahmen der Berichterstattung im Jahresabschluss stehen Steuerrisiken oben auf der Agenda, auch der amerikanische Internal Revenue Service (IRS) verfolgt das Thema sehr konsequent und plant, bestimmte Unternehmen zu Angaben von Steuerrisiken im Rahmen der Steuererklärungen zu verpflichten.
Der Aufsatz befasst sich mit den neueren Entwicklungen im Bereich der Bilanzierung und Offenlegung von unsicheren Steuerpositionen in der Rechnungslegung nach IFRS, US-GAAP und HGB und der Offenlegung von Steuerrisiken im Rahmen der Steuererklärung.
Die SPAC-SE ist börsenfähig und damit eine für eine SPAC grundsätzlich geeignete Rechtsform. Die Tatsache, dass es sich hierbei (zunächst) um eine leere, arbeitnehmerlose Hülle handelt, ändert hieran nichts. Die Gründung einer solchen Vorrats-SE ist trotz fehlender Arbeitnehmerbeteiligung unter teleologischer Reduktion von Art. 12 II SE-VO zulässig. Im Gegenzug muss die Arbeitnehmerbeteiligung gemaß § 18 III SEBG analog nachgeholt werden, wenn das später erworbene Zielunternehmen auf die SPAC-SE verschmolzen werden soll. Aus gesellschaftsrechtlicher Sicht ist zu beachten, dass die SPAC-SE mit Sitz in Deutschland, welche auch den deutschen, aktienrechtlichen Bestimmungen unterliegt, nur bedingt für eine SPAC geeignet erscheint. Das deutsche Aktienrecht enthält strenge Regelungen, die der für eine SPAC-SE erforderlichen Flexibilität entgegenstehen können. Dies gilt insbesondere für das Erfordernis der Zustimmung der Hauptversammlung zur Akquisition des Zielunternehmens, die Rückzahlung des Treuhandvermögens an Aktionäre, die der Akquisition nicht zugestimmt haben und die Liquidation der SPAC-SE im Falle des Scheiterns des Erwerbs des Zielobjektes.
C-terminal truncation of a metagenome-derived detergent protease for effective expression in E. coli
(2010)
Recently, a new alkaline protease named HP70 showing highest homology to extracellular serine proteases of Stenotrophomonas maltophilia and Xanthomonas campestris was found in the course of a metagenome screening for detergent proteases (Niehaus et al., submitted for publication). Attempts to efficiently express the enzyme in common expression hosts had failed. This study reports on the realization of overexpression in Escherichia coli after structural modification of HP70. Modelling of HP70 resulted in a two-domain structure, comprising the catalytic domain and a C-terminal domain which includes about 100 amino acids. On the basis of the modelled structure the enzyme was truncated by deletion of most of the C-terminal domain yielding HP70-C477.
This structural modification allowed effective expression of active enzyme using E. coli BL21-Gold as the host. Specific activity of HP70-C477 determined with suc-l-Ala-l-Ala-l-Pro-l-Phe-p-nitroanilide as the substrate was 30 ± 5 U/mg compared to 8 ± 1 U/mg of the native enzyme. HP70-C477 was most active at 40 °C and pH 7–11; these conditions are prerequisite for a potential application as detergent enzyme. Determination of kinetic parameters at 40 °C and pH = 9.5 resulted in KM = 0.23 ± 0.01 mM and kcat = 167.5 ± 3.6 s⁻¹. MS-analysis of peptide fragments obtained from incubation of HP70 and HP70-C477 with insulin B indicated that the C-terminal domain influences the cleavage preferences of the enzyme. Washing experiments confirmed the high potential of HP70-C477 as detergent protease.
A novel strategy for enhanced field-effect biosensing using capacitive electrolyte–insulator–semiconductor (EIS) structures functionalised with pH-responsive weak polyelectrolyte/enzyme or dendrimer/enzyme multilayers is presented. The feasibility of the proposed approach is exemplarily demonstrated by realising a penicillin biosensor based on a capacitive p-Si–SiO2 EIS structure functionalised with a poly(allylamine hydrochloride) (PAH)/penicillinase and a poly(amidoamine) dendrimer/penicillinase multilayer. The developed sensors response to changes in both the local pH value near the gate surface and the charge of macromolecules induced via enzymatic reaction, resulting in a higher sensitivity. For comparison, an EIS penicillin biosensor with adsorptively immobilised penicillinase has been also studied. The highest penicillin sensitivity of 100 mV/dec has been observed for the EIS sensor functionalised with the PAH/penicillinase multilayer. The lower and upper detection limit was around 20 µM and 10 mM, respectively. In addition, an incorporation of enzymes in a multilayer prepared by layer-by-layer technique provides a larger amount of immobilised enzymes per sensor area, reduces enzyme leaching effects and thus, enhances the biosensor lifetime (the loss of penicillin sensitivity after 2 months was 10–12%).
Capacitive field-effect electrolyte-diamond-insulator-semiconductor (EDIS) structures with O-terminated nanocrystalline diamond (NCD) as sensitive gate material have been realized and investigated for the detection of pH, penicillin concentration, and layer-by-layer adsorption of polyelectrolytes. The surface oxidizing procedure of NCD thin films as well as the seeding and NCD growth process on a Si-SiO2 substrate have been improved to provide high pH-sensitive, non-porous thin films without damage of the underlying SiO2 layer and with a high coverage of O-terminated sites. The NCD surface topography, roughness, and coverage of the surface groups have been characterized by SEM, AFM and XPS methods. The EDIS sensors with O-terminated NCD film treated in oxidizing boiling mixture for 45 min show a pH sensitivity of about 50 mV/pH. The pH-sensitive properties of the NCD have been used to develop an EDIS-based penicillin biosensor with high sensitivity (65-70 mV/decade in the concentration range of 0.25-2.5 mM penicillin G) and low detection limit (5 μM). The results of label-free electrical detection of layer-by-layer adsorption of charged polyelectrolytes are presented, too.
Objectives
Interest in cardiovascular magnetic resonance (CMR) at 7 T is motivated by the expected increase in spatial and temporal resolution, but the method is technically challenging. We examined the feasibility of cardiac chamber quantification at 7 T.
Methods
A stack of short axes covering the left ventricle was obtained in nine healthy male volunteers. At 1.5 T, steady-state free precession (SSFP) and fast gradient echo (FGRE) cine imaging with 7 mm slice thickness (STH) were used. At 7 T, FGRE with 7 mm and 4 mm STH were applied. End-diastolic volume, end-systolic volume, ejection fraction and mass were calculated.
Results
All 7 T examinations provided excellent blood/myocardium contrast for all slice directions. No significant difference was found regarding ejection fraction and cardiac volumes between SSFP at 1.5 T and FGRE at 7 T, while volumes obtained from FGRE at 1.5 T were underestimated. Cardiac mass derived from FGRE at 1.5 and 7 T was larger than obtained from SSFP at 1.5 T. Agreement of volumes and mass between SSFP at 1.5 T and FGRE improved for FGRE at 7 T when combined with an STH reduction to 4 mm.
Conclusions
This pilot study demonstrates that cardiac chamber quantification at 7 T using FGRE is feasible and agrees closely with SSFP at 1.5 T.
The objectives of the present work are to characterize the Gas Metal Arc Welding process of DP 600 sheet steel and to summarize the modelling techniques. The time-temperature evolution during the welding cycle was measured experimentally and modelled with the softwaretool SimWeld. To model the phase transformations during the welding cycle dilatometer tests were done to quantify the parameters for phase field modelling by MICRESS®. The important input parameters are interface mobility, nucleation density, etc. A contribution was made to include austenite to bainite transformation in MICRESS®. This is useful to predict the microstructure in the fast cooling segments. The phase transformation model is capable to predict the microstructure along the heating and cooling cycles of welding. Tensile tests have shown the evidence of failure at the heat affected zone, which has the ferrite-tempered martensite microstructure.
Molke fällt im Rahmen der Käseherstellung allein in Deutschland in Mengen von über 11 Mio. Tonnen jährlich an. Dieses Nebenprodukt wurde trotz seines Reichtums an Milchzucker und Proteinen lange Zeit kaum industriell weiterverarbeitet und stellte ein bedeutendes Problem bei der Abwasserreinigung dar. Derzeit kommen meist kosten- und reinigungsintensive Membranfiltrationsverfahren bei der Auftrennung von Molke in ihre Hauptkomponenten Lactose und Molkenprotein zum Einsatz. Die Produkte finden vorwiegend in der Nahrungsmittelindustrie Anwendung als Süßungsmittel, Proteinzusatz oder Texturbildner. Die Mehrheit des Proteins wird dabei als Konzentrat bzw. Proteinpulver verarbeitet. Wegen der antibakteriellen, antiviralen und weiteren wertvollen physiologischen Eigenschaften der Molkeproteine stellt eine weitere Aufreinigung der einzelnen Molkeproteine für die pharmazeutische Industrie einen naheliegenden zusätzlichen Wertschöpfungsschritt dar. In Kooperation mit der Süd Chemie AG wurde damit begonnen, ein Verfahren zu entwickeln, das kostengünstige mineralische Adsorbentien verwendet. Bisher konnte die Abtrennung von Lactose von den Molkenproteinen aus verdünntem Molkekonzentrat in einem Verfahrensschritt ohne Vorbehandlung des Rohstoffs erfolgreich realisiert werden. Aktuelle Arbeiten beschäftigen sich mit der Verbesserung der Proteinbindekapazitätund chromatographischen Proteinauftrennung sowie dem Upscaling zum direkten Einsatz von Molkekonzentrat ohne Vorverdünnung.
Comparison of intravenous immunoglobulins for naturally occurring autoantibodies against amyloid-β
(2010)
Intravenous immunoglobulins (IVIG) are currently used for therapeutic purposes in autoimmune disorders. Recently, we demonstrated the presence of naturally occurring antibodies against amyloid- β (nAbs-Aβ) within the pool of IVIG. In this study, we compared different brands of IVIG for nAbs-Aβ and have found differences in the specificity of the nAbs-Aβ towards Aβ1–40 and Aβ1–42 . We analyzed the influence of a pH-shift over the course of antibody storage using ELISA and investigated antibody dimerization at acidic and neutral pH as well as differences in the IgG subclass distributions among the IVIG using both HPLC and a nephelometric assay. Furthermore, we investigated the epitope region of purified nAbs-Aβ. The differences found in Aβ specificity are not directly proportionate to the binding nature of these antibodies when administered in vivo. This information, however, may serve as a guide when choosing the commercial source of IVIG for therapeutic applications in Alzheimer's disease
As high-field cardiac MRI (CMR) becomes more widespread the propensity of ECG to distortions and mistriggering increases and with it the motivation for a cardiac triggering alternative. Hence, this study explores the suitability of acoustic cardiac triggering (ACT) for left ventricular (LV) function assessment in healthy subjects at 1.5T and 3.0T.
Objective: As high-field cardiac MRI (CMR) becomes more widespread the propensity of ECG to interference from electromagnetic fields (EMF) and to magneto-hydrodynamic (MHD) effects increases and with it the motivation for a CMR triggering alternative. This study explores the suitability of acoustic cardiac triggering (ACT) for left ventricular (LV) function assessment in healthy subjects (n=14). Methods: Quantitative analysis of 2D CINE steady-state free precession (SSFP) images was conducted to compare ACT’s performance with vector ECG (VCG). Endocardial border sharpness (EBS) was examined paralleled by quantitative LV function assessment. Results: Unlike VCG, ACT provided signal traces free of interference from EMF or MHD effects. In the case of correct Rwave recognition, VCG-triggered 2D CINE SSFP was immune to cardiac motion effects—even at 3.0 T. However, VCG-triggered 2D SSFP CINE imaging was prone to cardiac motion and EBS degradation if R-wave misregistration occurred. ACT-triggered acquisitions yielded LV parameters (end-diastolic volume (EDV), endsystolic volume (ESV), stroke volume (SV), ejection fraction (EF) and left ventricular mass (LVM)) comparable with those derived fromVCG-triggered acquisitions (1.5 T: ESVVCG=(56± 17) ml, EDVVCG=(151±32)ml, LVMVCG=(97±27) g, SVVCG=(94± 19)ml, EFVCG=(63±5)% cf. ESVACT= (56±18) ml, EDVACT=(147±36) ml, LVMACT=(102±29) g, SVACT=(91± 22) ml, EFACT=(62±6)%; 3.0 T: ESVVCG=(55±21) ml, EDVVCG=(151±32) ml, LVMVCG=(101±27) g, SVVCG=(96±15) ml, EFVCG=(65±7)% cf. ESVACT=(54±20) ml, EDVACT=(146±35) ml, LVMACT= (101±30) g, SVACT=(92±17) ml, EFACT=(64±6)%). Conclusions: ACT’s intrinsic insensitivity to interference from electromagnetic fields renders
The CellDrum technology (The term 'CellDrum technology' includes a couple of slightly different technological setups for measuring lateral mechanical tension in various types of cell monolayers or 3D-tissue constructs) was designed to quantify the contraction rate and mechanical tension of self-exciting cardiac myocytes. Cells were grown either within flexible, circular collagen gels or as monolayer on top of respective 1-mum thin silicone membranes. Membrane and cells were bulged outwards by air pressure. This biaxial strain distribution is rather similar the beating, blood-filled heart. The setup allowed presetting the mechanical residual stress level externally by adjusting the centre deflection, thus, mimicking hypertension in vitro. Tension was measured as oscillating differential pressure change between chamber and environment. A 0.5-mm thick collagen-cardiac myocyte tissue construct induced after 2 days of culturing (initial cell density 2 x 10(4) cells/ml), a mechanical tension of 1.62 +/- 0.17 microN/mm(2). Mechanical load is an important growth regulator in the developing heart, and the orientation and alignment of cardiomyocytes is stress sensitive. Therefore, it was necessary to develop the CellDrum technology with its biaxial stress-strain distribution and defined mechanical boundary conditions. Cells were exposed to strain in two directions, radially and circumferentially, which is similar to biaxial loading in real heart tissues. Thus, from a biomechanical point of view, the system is preferable to previous setups based on uniaxial stretching.
Design and initial performance of PlanTIS: a high-resolution positron emission tomograph for plants
(2010)
Positron emitters such as 11C, 13N and 18F and their labelled compounds are widely used in clinical diagnosis and animal studies, but can also be used to study metabolic and physiological functions in plants dynamically and in vivo. A very particular tracer molecule is 11CO2 since it can be applied to a leaf as a gas. We have developed a Plant Tomographic Imaging System (PlanTIS), a high-resolution PET scanner for plant studies. Detectors, front-end electronics and data acquisition architecture of the scanner are based on the ClearPET™ system. The detectors consist of LSO and LuYAP crystals in phoswich configuration which are coupled to position-sensitive photomultiplier tubes. Signals are continuously sampled by free running ADCs, and data are stored in a list mode format. The detectors are arranged in a horizontal plane to allow the plants to be measured in the natural upright position. Two groups of four detector modules stand face-to-face and rotate around the field-of-view. This special system geometry requires dedicated image reconstruction and normalization procedures. We present the initial performance of the detector system and first phantom and plant measurements.
For more than a decade up to now there is an ongoing interest in small gas turbines downsized to micro-scale. With their high energy density they offer a great potential as a substitute for today’s unwieldy accumulators, found in a variety of applications like laptops, small tools etc. But micro-scale gas turbines could not only be used for generating electricity, they could also produce thrust for powering small unmanned aerial vehicles (UAVs) or similar devices. Beneath all the great design challenges with the rotating parts of the turbomachinery at this small scale, another crucial item is in fact the combustion chamber needed for a safe and reliable operation. With the so called regular micromix burning principle for hydrogen successfully downscaled in an initial combustion chamber prototype of 10 kW energy output, this paper describes a new design attempt aimed at the integration possibilities in a μ-scale gas turbine. For manufacturing the combustion chamber completely out of stainless steel components, a recuperative wall cooling was introduced to keep the temperatures in an acceptable range. Also a new way of an integrated ignition was developed. The detailed description of the prototype’s design is followed by an in depth report about the test results. The experimental investigations comprise a set of mass flow variations, coupled with a variation of the equivalence ratio for each mass flow at different inlet temperatures and pressures. With the data obtained by an exhaust gas analysis, a full characterisation concerning combustion efficiency and stability of the prototype chamber is possible. Furthermore the data show a full compliance with the expected operating requirements of the designated μ-scale gas turbine.
The idea of component-based software engineering was proposed more that 40 years ago, yet only few robotics software frameworks follow these ideas. The main problem with robotics software usually is that it runs on a particular platform and transferring source code to another platform is crucial. In this paper, we present our software framework Fawkes which follows the component-based software design paradigm by featuring a clear component concept with well-defined communication interfaces. We deployed Fawkes on several different robot platforms ranging from service robots to biped soccer robots. Following the component concept with clearly defined communication interfaces shows great benefit when porting robot software from one robot to the other. Fawkes comes with a number of useful plugins for tasks like timing, logging, data visualization, software configuration, and even high-level decision making. These make it particularly easy to create and to debug productive code, shortening the typical development cycle for robot software.
A handheld sensor system for the online measurement of hydrogen peroxide (H2O2) in aseptic sterilisation processes has been developed. It is based on a calorimetric-type gas sensor that consists of a differential set-up of two temperature sensors, of which one is catalytically activated and the second one is passivated and used as reference. The sensor principle relies in detecting a rise in temperature on the active sensor due to the exothermic reaction of H2O2 on the catalytic surface. To characterise the sensor system towards H2O2 sensitivity and other influencing factors, measurements have been carried out both at an experimental set-up and a manufacturer's sterilisation machine. Physical sensor characterisation was done by means of the optical microscopy.
Chalcogenide glass materials as membranes for potentiometric sensors for chemical analysis in solutions have been studied since more than 20 years. In this work, an electrolyte–insulator–semiconductor structure was combined with chalcogenide glass membranes prepared by means of the pulsed laser deposition technique. Depending on the membrane composition a selectivity to different ions (Cd2+ and Pb2+) is achieved. The different sensor membranes have been physically characterised using microscopy, ellipsometry, profilometry, atomic force microscopy (AFM), scanning electron microscopy (SEM) and Rutherford backscattering spectrometry (RBS). The electrochemical behaviour has been investigated via capacitance/voltage (C/V) and constant capacitance (ConCap) measurements and results in a Cd2+ sensitivity of 23.1 ± 0.6 mV per decade in a linear range from 7 × 10−6 to 10−2 mol/l and 24.4 ± 0.5 mV per decade in a linear range from 5 × 10−6 to 10−2 mol/l for Pb2+, respectively.