Refine
Year of publication
Document Type
- Conference Proceeding (129)
- Article (81)
- Part of a Book (27)
- Book (10)
- Report (3)
- Diploma Thesis (1)
- Doctoral Thesis (1)
- Talk (1)
Language
- English (138)
- German (114)
- Multiple languages (1)
Keywords
- Earthquake (5)
- Seismic design (4)
- INODIS (3)
- Out-of-plane load (3)
- Seismic loading (3)
- earthquakes (3)
- Adjacent buildings (2)
- Historical centres (2)
- INSYSME (2)
- Masonry infill (2)
- Shake table test (2)
- Stone masonry (2)
- Tanks (2)
- industrial facilities (2)
- installations (2)
- piping (2)
- seismic design (2)
- seismic loading (2)
- Artificial intelligence (1)
- Ausfachungsmauerwerk (1)
- BIM (1)
- Basisisolierung (1)
- Bauwerksüberwachung (1)
- Behaviour factor q (1)
- Bemessung (1)
- Blind prediction competition (1)
- Capacity Curve (1)
- Cardiovascular MRI (1)
- Civil engineering (1)
- Components (1)
- DIN EN 1996 (1)
- Decoupling (1)
- Design examples (1)
- EN 1998-4 (1)
- ESHM20, industrial facilities (1)
- Earthquake Engineering (1)
- Emilia-Romagna earthquake (1)
- Empirical consequence curves (1)
- Empirical fragility functions (1)
- Erdbeben (1)
- Erdbebeneinwirkung (1)
- Eurocode 8 (1)
- Frame structure (1)
- Genetic algorithm (1)
- Gust wind response (1)
- In- plane damage (1)
- In-plane (1)
- In-plane load (1)
- In-plane performance, isolation (1)
- Industrial facilities (1)
- Industrial units (1)
- Infill wall design (1)
- Interaction (1)
- Isolation (1)
- Left ventriular function (1)
- Linear elastic analysis (1)
- MR-stethoscope (1)
- Magnetic field strength (1)
- Magnetic resonance imaging (MRI) (1)
- Masonry partition walls (1)
- Masonry structures (1)
- Mauerwerksbauten (1)
- Mauerwerksgebäude (1)
- Modern constructions (1)
- Momentenverteilung (1)
- Monitoring (1)
- Monte Carlo Tree Search (1)
- Multi-storey (1)
- Neo-Deterministic (1)
- Numerical modelling (1)
- Out-of-plane (1)
- Out-of-plane capacity (1)
- Out-of-plane failure (1)
- Out-of-plane strength (1)
- PBEE (1)
- Piping (1)
- Precast buildings (1)
- Pushover analysis (1)
- PushoverAnalysen (1)
- RC frames (1)
- Rahmentragwirkung (1)
- Reinforced concrete frame (1)
- Response spectrum (1)
- Seismic (1)
- Seismic Hazard (1)
- Sensor (1)
- Silos (1)
- Slab deflection (1)
- Spectral analysis (1)
- Stahlbetonrahmen (1)
- Structural design (1)
- Structural health monitoring (1)
- Tank (1)
- Unreinforced masonry buildings (1)
- Unreinforced masonry walls (1)
- Verhaltensbeiwerte (1)
- Vulnerability Curves (1)
- Wand-Decken-Interaktion (1)
- Wind turbulence (1)
- Window opening (1)
- Ziegelmauerwerk (1)
- behaviour factor q (1)
- body limbs (1)
- cardiac gating (1)
- cardiovascular MR imaging (1)
- churches (1)
- connection detail (1)
- deserts (1)
- early warning and response system (1)
- earthquake (1)
- earthquake engineering (1)
- elastomeric bearing (1)
- electrocardiogram (1)
- equivalent stiffness (1)
- finite element method (1)
- fluid structure interaction (1)
- fragility curves (1)
- friction pendulum bearing (1)
- granular silo (1)
- high field MR imaging (1)
- hypoplasticity (1)
- impulsive effects (1)
- in-plane (1)
- in-plane and out-of-plane failure (1)
- in-plane behaviour (1)
- integration SHM in BIM (1)
- interconnected sensor systems (1)
- linear elastic analysis; (1)
- liquid storage tank (1)
- liquid-storage tank (1)
- liquid-structure interaction (1)
- lizards (1)
- macro-element (1)
- magnetic resonance imaging (1)
- masonry infill (1)
- masonry structures (1)
- modern constructions (1)
- nonlinear transient analyses (1)
- out-of-plane (1)
- out-of-plane behaviour (1)
- phonocardiogram (1)
- safety control (1)
- seismic (1)
- seismic hazard (1)
- seismic isolation (1)
- seismic response (1)
- seismic risk (1)
- seismic structural damage detection via SHM (1)
- seismic vulnerability (1)
- simplified approach (1)
- structure-soil-structure interaction (1)
- swimming (1)
- truss (1)
- unreinforced masonry buildings (1)
- vault (1)
- vocal fold oscillation (1)
Institute
This paper proposes a quick and simplified method to describe masonry vaults in global seismic analyses of buildings. An equivalent macro-element constituted by a set of six trusses, two for each transverse, longitudinal and diagonal direction, is introduced. The equivalent trusses, whose stiffness is calculated by fully modeled vaults of different geometry, mechanical properties and boundary conditions, simulate the vault in both global analysis and local analysis, such as kinematic or rocking approaches. A parametric study was carried out to investigate the influence of geometrical characteristics and mechanical features on the equivalent stiffness values. The method was numerically validated by performing modal and transient analysis on a three naves-church in the elastic range. Vibration modes and displacement time-histories were compared showing satisfying agreement between the complete and the simplified models. This procedure is particularly useful in engineering practice because it allows to assess, in a simplified way, the effectiveness of strengthening interventions for reducing horizontal relative displacements between vault supports.
Aufgrund der gestiegenen Anforderungen durch höhere Ein-wirkungen aus Wind und Erdbeben ist eine Verbesserung und Optimierung der Berechnungs- und Bemessungsansätze für Mauerwerksbauten erforderlich. Eine bessere Ausnutzung der Tragwerksreserven ist durch die Berücksichtigung der Rah-mentragwirkung mit einer Aktivierung der Deckenscheiben in den Rechenmodellen möglich, die in der Praxis aufgrund der Komplexität der Wand-Decken-Interaktion bislang nicht aus-genutzt wird. Im vorliegenden Aufsatz wird ein vereinfachter Ansatz auf Grundlage der mitwirkenden Plattenbreite von Schubwänden aus Mauerwerk vorgestellt, der die wesentli-chen Einfl ussfaktoren in parametrisierten Tabellen erfasst. Damit steht den Tragwerksplanern ein einfach anwendbares Werkzeug zur Verfügung, um die Rahmentragwirkung in der Mauerwerksbemessung anzusetzen.
Verformungsbasierter seismischer Nachweis von Mauerwerksbauten mit der Kapazitätsspektrum-Methode
(2005)
Because of its minor environmental impact, electricity generation using wind power is getting remarkable. The further growth of the wind industry depends on technological solutions to the challenges in production and construction of the turbines. Wind turbine tower vibrations, which limit power generation efficiency and cause fatigue problems with high maintenance costs, count as one of the main structural difficulties in the wind energy sector. To mitigate tower vibrations auxiliary measures are necessary. The effectiveness of tuned mass damper is verified by means of a numeric study on a 5 MW onshore reference wind turbine. Hereby, also seismic-induced vibrations and soil–structure interaction are considered. Acquired results show that tuned mass damper can effectively reduce resonant tower vibrations and improve the fatigue life of wind turbines. This chapter is also concerned with tuned liquid column damper and a semiactive application of it. Due to its geometric versatility and low prime costs, tuned liquid column dampers are a good alternative to other damping measures, in particular for slender structures like wind turbines.