Refine
Year of publication
Institute
- Fachbereich Elektrotechnik und Informationstechnik (1182) (remove)
Language
- English (717)
- German (464)
- Multiple languages (1)
Document Type
- Article (637)
- Conference Proceeding (302)
- Book (114)
- Part of a Book (64)
- Patent (16)
- Report (9)
- Other (8)
- Contribution to a Periodical (6)
- Course Material (6)
- Doctoral Thesis (6)
Keywords
- Multimediamarkt (7)
- Enterprise Architecture (5)
- MINLP (5)
- Engineering optimization (4)
- Gamification (4)
- Serious Game (4)
- Auslenkung (3)
- Digitale Transformation (3)
- Digitalisierung (3)
- Education (3)
Purpose
To design and evaluate a four-channel cardiac transceiver coil array for functional cardiac imaging at 7T.
Materials and Methods
A four-element cardiac transceiver surface coil array was developed with two rectangular loops mounted on an anterior former and two rectangular loops on a posterior former. specific absorption rate (SAR) simulations were performed and a Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-1 calibration method was applied prior to obtain 2D FLASH CINE (mSENSE, R = 2) images from nine healthy volunteers with a spatial resolution of up to 1 × 1 × 2.5 mm3.
Results
Tuning and matching was found to be better than 10 dB for all subjects. The decoupling (S21) was measured to be >18 dB between neighboring loops, >20 dB for opposite loops, and >30 dB for other loop combinations. SAR values were well within the limits provided by the IEC. Imaging provided clinically acceptable signal homogeneity with an excellent blood-myocardium contrast applying the Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-2 calibration approach.
Conclusion
A four-channel cardiac transceiver coil array for 7T was built, allowing for cardiac imaging with clinically acceptable signal homogeneity and an excellent blood-myocardium contrast. Minor anatomic structures, such as pericardium, mitral, and tricuspid valves and their apparatus, as well as trabeculae, were accurately delineated.
Design and Development of a Hot S-Parameter Measurement System for Plasma and Magnetron Applications
(2020)
This paper presents the design, development and calibration procedures of a novel hot S-parameter measurement system for plasma and magnetron applications with power level up to 6 kW. Based on a vector network analyzer, a power amplifier and two directional couplers, the input matching hotS 11 and transmission hotS 21 of the device under test are measured at 2.45 GHz center frequency and 300MHz bandwidth, while the device is driven by the magnetron. This measurement system opens a new horizon to develop many new industrial applications such as microwave plasma jets, dryer systems, dryers and so forth. Furthermore, the developing, controlling and monitoring a 2kW 2.45GHz plasma jet and a dryer system using the measurement system are presented and explained.
Design and Development of a Novel Self-Igniting Microwave Plasma Jet for Industrial Applications
(2019)
Design of a Measurement Setup for the Impedance of Low-Resistance Plate-Conductors in the RF-Range
(2006)
Zur Unterstützung des Transformationsbedarfs von Telekommunikationsunternehmen sind die Referenzmodelle des TM Forums in der Praxis weltweit anerkannt. Dabei findet jedoch meist eine losgelöste Nutzung für spezifische Einzelthemen statt. Daher führt dieser Artikel die bestehenden Inhalte in einer industriespezifischen, übergreifenden Referenzarchitektur zusammen. Der Fokus liegt auf den Ebenen Aufbauorganisation, Prozesse, Applikationen und Daten. Darüber hinaus werden inhaltliche Architekturdomänen zur Strukturierung angeboten. Die Referenzarchitektur ist hierarchisch aufgebaut und wird hier beispielhaft für ausgewählte, aggregierte Inhalte beschrieben. Als erste Evaluation wird die Anwendung der Referenzarchitektur in drei Praxisprojekten erläutert.