Refine
Year of publication
- 2010 (343) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (73)
- Fachbereich Wirtschaftswissenschaften (41)
- IfB - Institut für Bioengineering (40)
- Fachbereich Elektrotechnik und Informationstechnik (36)
- Fachbereich Chemie und Biotechnologie (35)
- Fachbereich Energietechnik (35)
- Fachbereich Maschinenbau und Mechatronik (31)
- Fachbereich Bauingenieurwesen (24)
- Fachbereich Luft- und Raumfahrttechnik (24)
- INB - Institut für Nano- und Biotechnologien (23)
Language
- English (187)
- German (153)
- Italian (2)
- Multiple languages (1)
Document Type
- Article (140)
- Conference Proceeding (100)
- Book (38)
- Part of a Book (23)
- Conference: Meeting Abstract (20)
- Patent (7)
- Report (5)
- Doctoral Thesis (2)
- Other (2)
- Part of a Periodical (2)
Keywords
- Aachen / Fachhochschule Aachen (3)
- Aachen University of Applied Sciences (3)
- FH Aachen (2)
- Geschichte (2)
- avalanche (2)
- humans (2)
- Adsorbentien (1)
- Cardiovascular MRI (1)
- Cardiovascular Magnetic Resonance (1)
- Commercial Vehicle (1)
Tricarbonylrhenium(I) and -technetium(I) halide (halide = Cl and Br) complexes of ligands derived from 4,5-diazafluoren-9-one (df) and 1,10-phenanthroline-5,6-dione (phen) derivatives of benzoic and 2-hydroxybenzoic acid hydrazides have been prepared. The complexes have been characterized by elemental analysis, MS, IR, 1H NMR and absorption and emission UV/Vis spectroscopic methods. The metal centres (ReI and TcI) are coordinated through the nitrogen imine atoms and establish five-membered chelate rings, whereas the hydrazone groups stand uncoordinated. The 1H NMR spectra suggest the same behaviour in solution on the basis of only marginal variations in the chemical shifts of the hydrazine protons.
This paper proposes an approach to the choice and evaluation of engineering models with the aid of a typical application in geotechnics. An important issue in the construction of shallow tunnels, especially in weak ground conditions, is the tunnel face stability. Various theoretical and numerical models for predicting the necessary support pressure have been put forth in the literature. In this paper, we combine laboratory experiments performed at the University of Innsbruck with current methods of uncertainty and sensitivity analysis for assessing adequacy, predictive power and robustness of the models. The major issues are the handling of the twofold uncertainty of test results and of model predictions as well as the decision about what are the influential input parameters.
Bead-on-plate butt joints of 2.5 mm hot rolled DP600/DP600 and 1.2 mm cold rolled TRIP700/TRIP700 steel sheets were performed using 6 kW CO2 laser beam welding. The welding speed ranged from 1.5 to 3.0 and from 2.1 to 3.9 m/min in DP/DP and TRIP/TRIP steel weldments respectively. A top surface helium gas was used as a shielding gas at a flow rate of 20 l/min. Metallographic examinations and transverse tensile testing (DIN EN 895: 1995) were carried out to characterize the weldments. The formability of base metals and weldments were investigated by standard Erichsen test (DIN EN ISO 20482). It was found that the uniaxial plastic behavior of both DP600 and TRIP700 base metals was in agreement with Swift and modified Mecking–Kocks models respectively. In a perpendicular tensile test to the weld line, all specimens were fractured at the base metal however the strengths were somewhat higher than those of base metal. There was a significant reduction in formability caused by welding of both DP/DP and TRIP/TRIP steel weldments and the formability has been improved with the increase of the welding speed.
During the development process of a complex technical product, one widely used and important technique is accelerated testing where the applied stress on a component is chosen to exceed the reference stress, i.e. the stress encountered in field operation, in order to reduce the time to failure. For that, the reference stress has to be known. Since a complex technical product may fail regarding numerous failure modes, stress in general is highly dimensional rather than scalar. In addition, customers use their products individually, i.e. field operation should be described by a distribution rather than by one scalar stress value. In this paper, a way to span the customer usage space is shown. It allows the identification of worst case reference stress profiles in significantly reduced dimensions with minimal loss of information. The application example shows that even for a complex product like a combustion engine, stress information can be compressed significantly. With low measurement effort it turned out that only three reference stress cycles were sufficient to cover a broad range of customer stress variety.
On the model of musculocutaneous wound in rats, the effect of applicative sorption by carbonized rise shell (CRS) on the healing of festering wound was studied. It has been shown, that cytological changes end with rapid scar formation. The use of CRS at the period of severe purulent wound contributes to its favorable course, prevents the development of complications of the animals from sepsis.
The integration of nanostructured films containing biomolecules and silicon-based technologies is a promising direction for reaching miniaturized biosensors that exhibit high sensitivity and selectivity. A challenge, however, is to avoid cross talk among sensing units in an array with multiple sensors located on a small area. In this letter, we describe an array of 16 sensing units of a light-addressable potentiometric sensor (LAPS), which was made with layer-by-layer (LbL) films of a poly(amidomine) dendrimer (PAMAM) and single-walled carbon nanotubes (SWNTs), coated with a layer of the enzyme penicillinase. A visual inspection of the data from constant-current measurements with liquid samples containing distinct concentrations of penicillin, glucose, or a buffer indicated a possible cross talk between units that contained penicillinase and those that did not. With the use of multidimensional data projection techniques, normally employed in information visualization methods, we managed to distinguish the results from the modified LAPS, even in cases where the units were adjacent to each other. Furthermore, the plots generated with the interactive document map (IDMAP) projection technique enabled the distinction of the different concentrations of penicillin, from 5 mmol L−1 down to 0.5 mmol L−1. Data visualization also confirmed the enhanced performance of the sensing units containing carbon nanotubes, consistent with the analysis of results for LAPS sensors. The use of visual analytics, as with projection methods, may be essential to handle a large amount of data generated in multiple sensor arrays to achieve high performance in miniaturized systems
The present article describes a standard instrument for the continuous online determination of retinal vessel diameters, the commercially available retinal vessel analyzer. This report is intended to provide informed guidelines for measuring ocular blood flow with this system. The report describes the principles underlying the method and the instruments currently available, and discusses clinical protocol and the specific parameters measured by the system. Unresolved questions and the possible limitations of the technique are also discussed.