Refine
Year of publication
- 2018 (255) (remove)
Document Type
- Article (124)
- Conference Proceeding (77)
- Part of a Book (30)
- Book (12)
- Working Paper (3)
- Doctoral Thesis (2)
- Other (2)
- Patent (2)
- Part of Periodical (2)
- Report (1)
Keywords
- Datenschutz (2)
- Digitale Transformation (2)
- Energy efficiency (2)
- Engineering optimization (2)
- Literaturanalyse (2)
- MINLP (2)
- Pump System (2)
- Serious Game (2)
- Water (2)
- Agility (1)
- Antarctica (1)
- Awareness (1)
- Bahadur efficiency (1)
- Bioethanol (1)
- Biorefinery (1)
- Bladder (1)
- Booster Stations (1)
- Buffering Capacity (1)
- CDG (1)
- Chance Constraint (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (67)
- Fachbereich Elektrotechnik und Informationstechnik (44)
- IfB - Institut für Bioengineering (41)
- INB - Institut für Nano- und Biotechnologien (25)
- Fachbereich Luft- und Raumfahrttechnik (24)
- Fachbereich Maschinenbau und Mechatronik (24)
- Fachbereich Energietechnik (22)
- Fachbereich Wirtschaftswissenschaften (21)
- Fachbereich Chemie und Biotechnologie (18)
- Fachbereich Bauingenieurwesen (16)
- Fachbereich Architektur (8)
- ECSM European Center for Sustainable Mobility (6)
- Solar-Institut Jülich (5)
- Fachbereich Gestaltung (4)
- Institut fuer Angewandte Polymerchemie (3)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (2)
- Nowum-Energy (2)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (2)
- FH Aachen (1)
Field-effect-based electrolyte-insulator-semiconductor (EIS) sensors were modified with a bilayer of positively charged weak polyelectrolyte (poly(allylamine hydrochloride) (PAH)) and probe single-stranded DNA (ssDNA) and are used for the detection of complementary single-stranded target DNA (cDNA) in different test solutions. The sensing mechanism is based on the detection of the intrinsic molecular charge of target cDNA molecules after the hybridization event between cDNA and immobilized probe ssDNA. The test solutions contain synthetic cDNA oligonucleotides (with a sequence of tuberculosis mycobacteria genome) or PCR-amplified DNA (which origins from a template DNA strand that has been extracted from Mycobacterium avium paratuberculosis-spiked human sputum samples), respectively. Sensor responses up to 41 mV have been measured for the test solutions with DNA, while only small signals of ∼5 mV were detected for solutions without DNA. The lower detection limit of the EIS sensors was ∼0.3 nM, and the sensitivity was ∼7.2 mV/decade. Fluorescence experiments using SybrGreen I fluorescence dye support the electrochemical results.