Refine
Year of publication
- 2010 (343) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (72)
- Fachbereich Wirtschaftswissenschaften (41)
- IfB - Institut für Bioengineering (40)
- Fachbereich Elektrotechnik und Informationstechnik (37)
- Fachbereich Energietechnik (35)
- Fachbereich Chemie und Biotechnologie (34)
- Fachbereich Maschinenbau und Mechatronik (31)
- Fachbereich Bauingenieurwesen (24)
- Fachbereich Luft- und Raumfahrttechnik (24)
- INB - Institut für Nano- und Biotechnologien (24)
Language
- English (185)
- German (155)
- Italian (2)
- Multiple languages (1)
Document Type
- Article (178)
- Conference Proceeding (74)
- Book (38)
- Part of a Book (20)
- Conference: Meeting Abstract (12)
- Patent (7)
- Report (5)
- Other (2)
- Part of a Periodical (2)
- Contribution to a Periodical (1)
Keywords
The determination of spacing, edge and end distance requirements for self-tapping screws requires numerous and comprehensive insertion tests. Yet the results of such tests cannot be transferred to other types of screws or even to screws of different diameter because of differences in shape or geometry. To reduce the effort of insertion tests a new method was developed which allows the estimation of required spacings, distances and timber thickness.
A novel scheme for precise diagnostics and effective stabilization of currents in a fuel cell stack
(2010)
Background
To demonstrate the applicability of acoustic cardiac triggering (ACT) for imaging of the heart at ultrahigh magnetic fields (7.0 T) by comparing phonocardiogram, conventional vector electrocardiogram (ECG) and traditional pulse oximetry (POX) triggered 2D CINE acquisitions together with (i) a qualitative image quality analysis, (ii) an assessment of the left ventricular function parameter and (iii) an examination of trigger reliability and trigger detection variance derived from the signal waveforms.
Results
ECG was susceptible to severe distortions at 7.0 T. POX and ACT provided waveforms free of interferences from electromagnetic fields or from magneto-hydrodynamic effects. Frequent R-wave mis-registration occurred in ECG-triggered acquisitions with a failure rate of up to 30% resulting in cardiac motion induced artifacts. ACT and POX triggering produced images free of cardiac motion artefacts. ECG showed a severe jitter in the R-wave detection. POX also showed a trigger jitter of approximately Δt = 72 ms which is equivalent to two cardiac phases. ACT showed a jitter of approximately Δt = 5 ms only. ECG waveforms revealed a standard deviation for the cardiac trigger offset larger than that observed for ACT or POX waveforms.
Image quality assessment showed that ACT substantially improved image quality as compared to ECG (image quality score at end-diastole: ECG = 1.7 ± 0.5, ACT = 2.4 ± 0.5, p = 0.04) while the comparison between ECG vs. POX gated acquisitions showed no significant differences in image quality (image quality score: ECG = 1.7 ± 0.5, POX = 2.0 ± 0.5, p = 0.34).
Conclusions
The applicability of acoustic triggering for cardiac CINE imaging at 7.0 T was demonstrated. ACT's trigger reliability and fidelity are superior to that of ECG and POX. ACT promises to be beneficial for cardiovascular magnetic resonance at ultra-high field strengths including 7.0 T.