Refine
Year of publication
Institute
- Fachbereich Energietechnik (1066) (remove)
Has Fulltext
- no (1066) (remove)
Language
- English (561)
- German (502)
- Multiple languages (1)
- Dutch (1)
- Spanish (1)
Document Type
- Article (598)
- Conference Proceeding (226)
- Book (125)
- Part of a Book (83)
- Doctoral Thesis (10)
- Conference: Meeting Abstract (7)
- Report (7)
- Other (4)
- Talk (2)
- Contribution to a Periodical (1)
Keywords
- Earthquake (5)
- Diversity Management (4)
- Energy storage (4)
- Power plants (4)
- Seismic design (4)
- Associated liquids (3)
- Concentrated solar power (3)
- Hybrid energy system (3)
- INODIS (3)
- Out-of-plane load (3)
Risk management for structures with a risk of explosion should be considered very carefully when performing a risk analysis according to IEC 62305-2. In contrast to the 2006 edition of the standard, the 2010 edition describes the topic “Structures with a risk of explosion” in more detail. Moreover, in Germany separate procedures and parameters are defined for the risk analysis of structures with a risk of explosion (Supplement 3 of the German DIN EN 62305-2 standard). This paper describes the contents and the relevant calculations of this Supplement 3, together with a numerical example.
Am 1. Oktober 2013 ist das auf drei Jahre angelegte EU-Forschungsprojekt INSYSME – Innovative Systeme für erdbebentaugliche Ausfachungswände aus Ziegelmauerwerk in Stahlbetonrahmentragwerken – gestartet. Unter der Koordination der Universität Padua beteiligen sich 16 Partner aus sechs europäischen Ländern (Deutschland, Griechenland, Italien, Portugal, Rumänien, Türkei). Als deutsche Partner nehmen die Arbeitsgemeinschaft Mauerziegel aus Bonn, die Universität Kassel sowie das Ingenieurbüro SDA-engineering GmbH aus Herzogenrath, teil. Ziel der deutschen Partner ist die Entwicklung von innovativen Ausfachungssystemen aus monolithischem wärmedämmenden Ziegelmauerwerk, mit denen nicht nur eine erhöhte Erdbebensicherheit, sondern auch die sichere Erfüllung der steigenden Anforderungen aus Windbeanspruchungen gewährleistet werden können. Die Forschungsergebnisse sollen vom Partner SDA-engineering GmbH in die bereits seit einigen Jahren verfügbare Softwarelösung MINEA [1] integriert werden. Weitere Informationen stehen auf den Websites des Projektes [2] zur Verfügung. Im vorliegenden Beitrag werden nach einer kurzen thematischen Einführung die Ergebnisse von Tastversuchen an senkrecht zur Ebene belasteten Ausfachungswänden aus Planziegelmauerwerk vorgestellt. Im Anschluss wird das geplante Arbeitsprogramm der deutschen Partner im Projekt INSYSME beschrieben.
Die Erdbeben in Albstadt 1978 (Magnitude 5,7), Roermond 1992 (Magnitude 5,9) oder in Waldkirch 2004 (Magnitude 5,1) haben verdeutlicht, dass die erdbebensichere Auslegung von Mauerwerksbauten auch in Deutschland von großer Bedeutung ist. Bereits im Jahr 1981 wurde die DIN 4149 (1981) “Bauten in deutschen Erdbebengebieten – Lastannahmen, Bemessung und Ausführung üblicher Hochbauten“ eingeführt, in der aber für Mauerwerksbauten nur wenige Anforderungen gestellt wurden. Diese Norm wurde durch den NABau-Arbeitsausschuss “Erdbeben; Sonderfragen“ des Deutschen Instituts für Normung e.V. (DIN) auf Grundlage des Eurocode 8 (2004) vollständig überarbeitet und durch die DIN 4149 (2005) abgelöst, die umfangreiche Regelungen für die seismische Auslegung von Mauerwerksbauten enthält. Mittlerweile liegen die DIN EN 1998-1 (2010) und der Nationale Anhang DIN EN 1998-1/NA (2011) vor, die nach Einarbeitung der Ergebnisse der durchgeführten Anwendungserprobung bauaufsichtlich eingeführt und die DIN 4149 (2005) ersetzen werden. Der folgende Beitrag gibt einen Überblick über die seismische Berechnung und Bemessung von Mauerwerksbauten nach dem europäischen Regelwerk und illustriert deren Anwendung an einem baupraktischen Beispiel.
EU-Projekt INSYSME : innovative Systeme für erdbebentaugliche Ausfachungswände aus Ziegelmauerwerk
(2014)
New coupled finite-infinite element approach for wave propagation simulation of unbounded soil media
(2014)
Die PIA GmbH prüft seit fast 8 Jahren die Standsicherheit von Behältern für Kleinkläranlagen. Diese bestehen in der Regel aus Kunststoff oder Beton und müssen über ihre gesamte Lebensdauer den Beanspruchungen aus Handhabung, Einbau und Betrieb standhalten. Die Standsicherheit kann nach EN 12566 wahlweise durch einen rechnerischen Nachweis oder durch einen praktischen Nachweis wie die Bruchlastprüfung oder die Prüfung in der Grube erfolgen.
Because of its minor environmental impact, electricity generation using wind power is getting remarkable. The further growth of the wind industry depends on technological solutions to the challenges in production and construction of the turbines. Wind turbine tower vibrations, which limit power generation efficiency and cause fatigue problems with high maintenance costs, count as one of the main structural difficulties in the wind energy sector. To mitigate tower vibrations auxiliary measures are necessary. The effectiveness of tuned mass damper is verified by means of a numeric study on a 5 MW onshore reference wind turbine. Hereby, also seismic-induced vibrations and soil–structure interaction are considered. Acquired results show that tuned mass damper can effectively reduce resonant tower vibrations and improve the fatigue life of wind turbines. This chapter is also concerned with tuned liquid column damper and a semiactive application of it. Due to its geometric versatility and low prime costs, tuned liquid column dampers are a good alternative to other damping measures, in particular for slender structures like wind turbines.
Die erdbebensichere Auslegung von erdverlegten Rohrleitungssystemen ist von wesentlicher Bedeutung zur Sicherstellung der Funktionalität der Versorgungsinfrastruktur nach einem Erdbebenereignis. Zur Vermeidung von Netzausfällen ist es erforderlich, die räumlich weit ausgedehnten Leitungssysteme mit geeigneten rechnerischen Modellen seismisch zu bemessen. Der vorliegende Beitrag behandelt die Beanspruchung von Rohrleitungssystemen durch seismische Welleneinwirkung und stellt geeignete Näherungsansätze und ein detailliertes Rechenmodell für seismische Leitungsanalysen vor. Mit den Ansätzen wird in Berechnungsbeispielen der Einfluss wesentlicher Parameter auf die seismisch induzierten Dehnungen in Rohrleitungssystemen untersucht.
Simulating the electromagnetic‐thermal treatment of thin aluminium layers for adhesion improvement
(2015)
A composite layer material used in packaging industry is made from joining layers of different materials using an adhesive. An important processing step in the production of aluminium-containing composites is the surface treatment and consequent coating of adhesive material on the aluminium surface. To increase adhesion strength between aluminium layer and the adhesive material, the foil is heat treated. For efficient heating, induction heating was considered as state-of-the-art treatment process. Due to the complexity of the heating process and the unpredictable nature of the heating source, the control of the process is not yet optimised. In this work, a finite element analysis of the process was established and various process parameters were studied. The process was simplified and modelled in 3D. The numerical model contains an air domain, an aluminium layer and a copper coil fitted with a magnetic field concentrating material. The effect of changing the speed of the aluminium foil (or rolling speed) was studied with the change of the coil current. Statistical analysis was used for generating a general control equation of coil current with changing rolling speed.
Lately there has been an increasing concern about uranium toxicity in some districts of Punjab State located in the North Western part of India after the publication of a report (Blaurock-Busch et al. 2010) which showed that the concentration of uranium in hair and urine of children suffering from physical deformities, neurological and mental disorder from Malwa region (Fig. 1) of Punjab State was manifold higher than the reference ranges. A train which connects the affected region with the nearby city of Bikaner which has a Cancer Hospital has been nicknamed as Cancer Express due to the frenzy generated on account of uranium related toxicity.
Globale Stabilitätsanalysen zylindrischer, seismisch belasteter Tanks auf numerischer Grundlage
(2015)
Within the framework of the project a genderand diversity-oriented teaching evaluation and modern, media-supported blended learning approaches were used in order to achieve the intended goals. First research results of the literature and status quo analysis were already implemented and tested in newly designed teaching approaches, for example in a multidisciplinary introductory lecture of civil engineering at RWTH Aachen University.