Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (1569) (remove)
Has Fulltext
- no (1569) (remove)
Language
- English (1569) (remove)
Document Type
- Article (1314)
- Conference Proceeding (135)
- Book (43)
- Part of a Book (43)
- Doctoral Thesis (18)
- Other (6)
- Patent (4)
- Preprint (3)
- Conference: Meeting Abstract (1)
- Habilitation (1)
Keywords
- LAPS (4)
- Natural language processing (4)
- CellDrum (3)
- Field-effect sensor (3)
- Light-addressable potentiometric sensor (3)
- Paired sample (3)
- hydrogen peroxide (3)
- impedance spectroscopy (3)
- Bacillus atrophaeus (2)
- Biocomposites (2)
Rationale: Previous studies [Topolnik et al., Cereb Cortex 2003; 13: 883; Schindler et al., Brain 2007; 130: 65] indicate that the termination of focal onset seizures may be causally related to an increase of global neuronal correlation during the second half of the seizures. This increase was observed to occur earlier in complex partial seizures than in secondarily generalized seizures. We here address the question whether such an increase of neuronal correlation prior to seizure end is indeed a global phenomenon, involving both hemispheres or whether there are side-specific differences. Methods: We analyzed 20 focal onset seizures (10 complex partial, 10 secondarily generalized seizures) recorded in 13 patients who underwent presurgical evaluation of focal epilepsies of different origin. EEG was recorded intracranially from bilaterally implanted subdural strip and intrahippocampal depth electrodes. Utilizing a moving window approach, we investigated the evolution of the maximum cross correlation for all channel combinations during seizures. For each moving window the mean value of the maximum cross correlation (MCC) between all electrode contacts was computed separately for each hemisphere. After normalization of seizure durations, MCC values of the ipsi- and contralateral hemisphere for all seizures were determined. Results: We observed that the MCC of the contralateral hemisphere in complex partial seizures increased during the first half of the seizure, whereas, for the same time interval, the MCC of the ipsilateral hemisphere even declined below the level of the pre-seizure period. In contrast, no significant differences between both hemispheres could be observed for secondarily generalized seizures where both hemispheres showed a simultaneous increase of MCC during the second half of the seizures. The level of MCC for the contralateral hemisphere was higher for complex partial seizures than for secondarily generalized seizures during the first half of the seizure. Conclusions: Our findings indicate that there are indeed lateralized differences in the evolution of global neuronal correlation during complex partial and secondarily generalized seizures. The observed contralateral increase of neuronal correlation during complex partial seizures might indicate an emerging self-organizing mechanism for preventing the spread of seizure activity.
Layer-by-Layer Assembly of Carbon Nanotubes Incorporated in Light-Addressable Potentiometric Sensors
(2009)
Lead and nickel, as heavy metals, are still used in industrial processes, and are classified as “environmental health hazards” due to their toxicity and polluting potential. The detection of heavy metals can prevent environmental pollution at toxic levels that are critical to human health. In this sense, the electrolyte–insulator–semiconductor (EIS) field-effect sensor is an attractive sensing platform concerning the fabrication of reusable and robust sensors to detect such substances. This study is aimed to fabricate a sensing unit on an EIS device based on Sn₃O₄ nanobelts embedded in a polyelectrolyte matrix of polyvinylpyrrolidone (PVP) and polyacrylic acid (PAA) using the layer-by-layer (LbL) technique. The EIS-Sn₃O₄ sensor exhibited enhanced electrochemical performance for detecting Pb²⁺ and Ni²⁺ ions, revealing a higher affinity for Pb²⁺ ions, with sensitivities of ca. 25.8 mV/decade and 2.4 mV/decade, respectively. Such results indicate that Sn₃O₄ nanobelts can contemplate a feasible proof-of-concept capacitive field-effect sensor for heavy metal detection, envisaging other future studies focusing on environmental monitoring.
The mechanical behavior of the large intestine beyond the ultimate stress has never been investigated. Stretching beyond the ultimate stress may drastically impair the tissue microstructure, which consequently weakens its healthy state functions of absorption, temporary storage, and transportation for defecation. Due to closely similar microstructure and function with humans, biaxial tensile experiments on the porcine large intestine have been performed in this study. In this paper, we report hyperelastic characterization of the large intestine based on experiments in 102 specimens. We also report the theoretical analysis of the experimental results, including an exponential damage evolution function. The fracture energies and the threshold stresses are set as damage material parameters for the longitudinal muscular, the circumferential muscular and the submucosal collagenous layers. A biaxial tensile simulation of a linear brick element has been performed to validate the applicability of the estimated material parameters. The model successfully simulates the biomechanical response of the large intestine under physiological and non-physiological loads.
In this review article, we are going to present an overview on possible applications of light-addressable electrodes (LAE) as actuator/manipulation devices besides classical electrode structures. For LAEs, the electrode material consists of a semiconductor. Illumination with a light source with the appropiate wavelength leads to the generation of electron-hole pairs which can be utilized for further photoelectrochemical reaction. Due to recent progress in light-projection technologies, highly dynamic and flexible illumination patterns can be generated, opening new possibilities for light-addressable electrodes. A short introduction on semiconductor–electrolyte interfaces with light stimulation is given together with electrode-design approaches. Towards applications, the stimulation of cells with different electrode materials and fabrication designs is explained, followed by analyte-manipulation strategies and spatially resolved photoelectrochemical deposition of different material types.