Refine
Year of publication
Institute
- Fachbereich Energietechnik (1067) (remove)
Has Fulltext
- no (1067) (remove)
Language
- English (562)
- German (502)
- Multiple languages (1)
- Dutch (1)
- Spanish (1)
Document Type
- Article (598)
- Conference Proceeding (226)
- Book (126)
- Part of a Book (83)
- Doctoral Thesis (10)
- Conference: Meeting Abstract (7)
- Report (7)
- Other (4)
- Talk (2)
- Contribution to a Periodical (1)
Keywords
- Earthquake (5)
- Diversity Management (4)
- Energy storage (4)
- Power plants (4)
- Seismic design (4)
- Associated liquids (3)
- Concentrated solar power (3)
- Hybrid energy system (3)
- INODIS (3)
- Out-of-plane load (3)
Extrem hohe Blitzströme
(2018)
Blitze sind nach wie vor eine enorme Schadensquelle für Personenschäden, Brände, mechanische Zerstörungen und insbesondere auch Überspannungen. Das zeigen nicht zuletzt aktuelle Statistiken der Schadensversicherer. Immer wieder gibt es Meldungen über extrem hohe Blitzströme, die natürlich auch zu großen Schäden und Zerstörungen führen können. Dabei werden Scheitelwerte von teilweise deutlich über 300 kA genannt. Dies wirft Fragen auf, da die „klassische“ Blitzstatistik (z. B. nach CIGRE und IEC [8][10]) bisher solche Werte nicht kennt. Diese extremen Blitzströme werden meist aus den Daten von Blitzortungssystemen ermittelt.
Seismic design of buried pipeline systems for energy and water supply is not only important for plant and operational safety but also for the maintenance of the supply infrastructure after an earthquake. The present paper shows special issues of the seismic wave impacts on buried pipelines, describes calculation methods, proposes approaches and gives calculation examples. This paper regards the effects of transient displacement differences and resulting tensions within the pipeline due to the wave propagation of the earthquake. However, the presented model can also be used to calculate fault rupture induced displacements. Based on a three-dimensional Finite Element Model parameter studies are performed to show the influence of several parameters such as incoming wave angle, wave velocity, backfill height and synthetic displacement time histories. The interaction between the pipeline and the surrounding soil is modeled with non-linear soil springs and the propagating wave is simulated affecting the pipeline punctually, independently in time and space. Special attention is given to long-distance heat pipeline systems. Here, in regular distances expansion bends are arranged to ensure movements of the pipeline due to high temperature. Such expansion bends are usually designed with small bending radii, which during the earthquake lead to high bending stresses in the cross-section of the pipeline. Finally, an interpretation of the results and recommendations are given for the most critical parameters.
Frequency Dependent Impedance Analysis of the Foundation-Soil-Systems of Onshore Wind Turbines
(2018)
Reinforced concrete (RC) frames with masonry infills are frequently used in seismic regions all over the world. Generally masonry infills are considered as nonstructural elements and thus are typically neglected in the design process. However, the observations made after strong earthquakes have shown that masonry infills can modify the dynamic behavior of the structure significantly. The consequences were total collapses of buildings and loss of human lives. This paper presents the new system INODIS (Innovative Decoupled Infill System) developed within the European research project INSYSME (Innovative Systems for Earthquake Resistant Masonry Enclosures in RC Buildings). INODIS decouples the frame and the masonry infill by means of special U-shaped rubbers placed in between frame and infill. The effectiveness of the system was investigated by means of full scale tests on RC frames with masonry infills subjected to in-plane and out-of-plane loading. Furthermore small specimen tests were conducted to determine material characteristics of the components and the resistances of the connections. Finally, a micromodel was developed to simulate the in-plane behavior of RC frames infilled with AAC blocks with and without installation of the INODIS system.