Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (2071)
- Fachbereich Elektrotechnik und Informationstechnik (1183)
- Fachbereich Wirtschaftswissenschaften (1158)
- Fachbereich Energietechnik (1115)
- Fachbereich Chemie und Biotechnologie (912)
- Fachbereich Maschinenbau und Mechatronik (867)
- Fachbereich Luft- und Raumfahrttechnik (796)
- Fachbereich Bauingenieurwesen (711)
- IfB - Institut für Bioengineering (686)
- INB - Institut für Nano- und Biotechnologien (615)
Language
- German (5099)
- English (4903)
- Russian (14)
- Portuguese (6)
- Multiple languages (5)
- Spanish (3)
- Dutch (2)
- Italian (1)
Document Type
- Article (5641)
- Conference Proceeding (1638)
- Book (1079)
- Part of a Book (559)
- Bachelor Thesis (312)
- Patent (174)
- Report (101)
- Doctoral Thesis (79)
- Other (76)
- Administrative publication (76)
Keywords
- Amtliche Mitteilung (71)
- Bachelor (33)
- Aachen University of Applied Sciences (31)
- Master (31)
- Prüfungsordnung (31)
- Bauingenieurwesen (30)
- Lesbare Fassung (28)
- Biosensor (25)
- Fachhochschule Aachen (23)
- Illustration (22)
Zugriffsart
- campus (2141)
- weltweit (1857)
- bezahl (762)
- fachbereichsweit (FB4) (30)
Electronic cigarettes (e-cigarettes) have become popular worldwide with the market growing exponentially in some countries. The absence of product standards and safety regulations requires urgent development of analytical methodologies for the holistic control of the growing diversity of such products. An approach based on low-field nuclear magnetic resonance (LF-NMR) at 80 MHz is presented for the simultaneous determination of key parameters: carrier solvents (vegetable glycerine (VG), propylene glycol (PG) and water), total nicotine as well as free-base nicotine fraction. Moreover, qualitative and quantitative determination of fourteen weak organic acids deliberately added to enhance sensory characteristics of e-cigarettes was possible. In most cases these parameters can be rapidly and conveniently determined without using any sample manipulation such as dilution, extraction or derivatization steps. The method was applied for 37 authentic e-cigarettes samples. In particular, eight different organic acids with the content up to 56 mg/mL were detected. Due to its simplicity, the method can be used in routine regulatory control as well as to study release behaviour of nicotine and other e-cigarettes constituents in different products.
With the prevalence of glucosamine- and chondroitin-containing dietary supplements for people with osteoarthritis in the marketplace, it is important to have an accurate and reproducible analytical method for the quantitation of these compounds in finished products. NMR spectroscopic method based both on low- (80 MHz) and high- (500–600 MHz) field NMR instrumentation was established, compared and validated for the determination of chondroitin sulfate and glucosamine in dietary supplements. The proposed method was applied for analysis of 20 different dietary supplements. In the majority of cases, quantification results obtained on the low-field NMR spectrometer are similar to those obtained with high-field 500–600 MHz NMR devices. Validation results in terms of accuracy, precision, reproducibility, limit of detection and recovery demonstrated that the developed method is fit for purpose for the marketed products. The NMR method was extended to the analysis of methylsulfonylmethane, adulterant maltodextrin, acetate and inorganic ions. Low-field NMR can be a quicker and cheaper alternative to more expensive high-field NMR measurements for quality control of the investigated dietary supplements. High-field NMR instrumentation can be more favorable for samples with complex composition due to better resolution, simultaneously giving the possibility of analysis of inorganic species such as potassium and chloride.
In der Abschlussarbeit „FILOS“ wurde in Zusammenarbeit mit dem Fraunhofer-Institut für Lasertechnik (ILT) ein Front-End für das laserbasierte Osteotom STELLA entwickelt. STELLA soll Kraniotomie (das Eröffnen des Schädels) im wachen Zustand ermöglichen und erfordert eine benutzerfreundliche Bedienungsplattform sowie ein funktionales und ästhetisches Design. Das Ziel von „FILOS“ war es, ein Gehäuse zu entwerfen, das den medizinischen Anforderungen entspricht, und ein Bedienkonzept zu entwickeln, dass die Akzeptanz bei Patient:innen und Anwender:innen fördert. Durch Expert:innen-Interviews mit Neurochirurg:innen und enge Zusammenarbeit mit dem ILT wurde ein durchdachtes Design entwickelt. Dieses soll den Anforderungen der Anwender:innen gerecht werden, das zukünftige Operationssystem repräsentieren und somit einen Mehrwert in der Medizin schaffen.