Refine
Year of publication
Institute
- Fachbereich Energietechnik (61)
- Fachbereich Elektrotechnik und Informationstechnik (57)
- Fachbereich Luft- und Raumfahrttechnik (25)
- Solar-Institut Jülich (17)
- Fachbereich Medizintechnik und Technomathematik (13)
- Fachbereich Maschinenbau und Mechatronik (12)
- ECSM European Center for Sustainable Mobility (11)
- Fachbereich Wirtschaftswissenschaften (6)
- IfB - Institut für Bioengineering (5)
- INB - Institut für Nano- und Biotechnologien (4)
- Fachbereich Bauingenieurwesen (3)
- Fachbereich Chemie und Biotechnologie (2)
- Fachbereich Gestaltung (2)
- Sonstiges (2)
- Nowum-Energy (1)
Document Type
- Article (100)
- Conference Proceeding (46)
- Book (31)
- Part of a Book (17)
- Conference: Meeting Abstract (2)
- Bachelor Thesis (1)
- Patent (1)
- Report (1)
Keywords
- Blitzschutz (4)
- Lightning protection (4)
- Literaturanalyse (3)
- Digitale Transformation (2)
- Digitalisierung (2)
- Erneuerbare Energien (2)
- Forschungsprozess (2)
- Hybridsystem (2)
- Robotic Process Automation (2)
- Text Analytics (2)
As researchers continue to seek the expansion of the material base for additive manufacturing, there is a need to focus attention on the Ni–Cu group of alloys which conventionally has wide industrial applications. In this work, the G-NiCu30Nb casting alloy, a variant of the Monel family of alloys with Nb and high Si content is, for the first time, processed via the laser powder bed fusion process (LPBF). Being novel to the LPBF processes, optimum LPBF parameters were determined, and hardness and tensile tests were performed in as-built conditions and after heat treatment at 1000 °C. Microstructures of the as-cast and the as-built condition were compared. Highly dense samples (99.8% density) were achieved after varying hatch distance (80 µm and 140 µm) with scanning speed (550 mm/s–1500 mm/s). There was no significant difference in microhardness between varied hatch distance print sets. Microhardness of the as-built condition (247 HV0.2) exceeded the as-cast microhardness (179 HV0.2.). Tensile specimens built in vertical (V) and horizontal (H) orientations revealed degrees of anisotropy and were superior to conventionally reported figures. Post heat treatment increased ductility from 20% to 31% (V), as well as from 16% to 25% (H), while ultimate tensile strength (UTS) and yield strength (YS) were considerably reduced.
Der „Male Gaze“ bezeichnet das typische Erleben der Umwelt aus männlicher Perspektive und prägt in den sogenannten Mainstream-Medien die Gestaltung von Film, Fernsehen und Werbung. Dadurch werden von dargestellten Personen häufig die körperlichen Aspekte hervorgehoben. Im Gegensatz dazu gilt das weibliche Pendant, der „Female Gaze“, als besonders emotionsbetont. Weil Medien einen enormen Einfluss auf gesellschaftliches und individuelles Denken haben, stellt die Dominanz des „Male Gaze“ eine Unausgeglichenheit dar, die sich in verschiedenen Bereichen des gesellschaftlichen Lebens widerspiegelt. Deswegen möchte dieses Projekt die Medien um die weibliche Sichtweise erweitern und damit die dort transportierten Bilder diverser und ausgewogener machen. Die Fotografie fokussiert sich dabei auf die Gefühlswelt der Protagonistin, womit die Betrachter:Innen schrittweise in ihre Position hineinversetzt werden sollen. Mit Augen des Mitgefühls und eigenem Schönheitsbegriff lässt „Falling in love with the female gaze“ endlich auch die Frau zu Wort kommen.
With its need for high SNR and short acquisition times, Cardiac MRI (CMR) is an intriguing target application for ultrahigh field MRI. Due to the sheer size of the upper torso, however, the known RF issues of 7T MRI are also most prominent in CMR. Recent years brought substantial progress but the full potential of the ultrahigh field for CMR is yet to be exploited. Parallel transmission (pTx) is a promising approach in this context and several groups have already reported B1 shimming for 7T CMR. In such a static pTx application amplitudes and phases of all Tx channels are adjusted individually but otherwise imaging techniques established in current clinical practice 1.5 T and 3 T are applied. More advanced forms of pTx as spatially selective excitation (SSE) using Transmit SENSE promise additional benefits like faster imaging with reduced fields of view or improved SAR control. SSE requires the full dynamic capabilities of pTx, however, and for the majority of today's implemented pTx hardware the internal synchronization of the Tx array does not easily permit external triggering as needed for CMR. Here we report a software solution to this problem and demonstrate the feasibility of CINE CMR at 7 T using a Tx array.
This paper compares several blade element theory (BET) method-based propeller simulation tools, including an evaluation against static propeller ground tests and high-fidelity Reynolds-Average Navier Stokes (RANS) simulations. Two proprietary propeller geometries for paraglider applications are analysed in static and flight conditions. The RANS simulations are validated with the static test data and used as a reference for comparing the BET in flight conditions. The comparison includes the analysis of varying 2D aerodynamic airfoil parameters and different induced velocity calculation methods. The evaluation of the BET propeller simulation tools shows the strength of the BET tools compared to RANS simulations. The RANS simulations underpredict static experimental data within 10% relative error, while appropriate BET tools overpredict the RANS results by 15–20% relative error. A variation in 2D aerodynamic data depicts the need for highly accurate 2D data for accurate BET results. The nonlinear BET coupled with XFOIL for the 2D aerodynamic data matches best with RANS in static operation and flight conditions. The novel BET tool PropCODE combines both approaches and offers further correction models for highly accurate static and flight condition results.
The aerodynamic performance of propellers strongly depends on their geometry and, consequently, on aeroelastic deformations. Knowledge of the extent of the impact is crucial for overall aircraft performance. An integrated simulation environment for steady aeroelastic propeller simulations is presented. The simulation environment is applied to determine the impact of elastic deformations on the aerodynamic propeller performance. The aerodynamic module includes a blade element momentum approach to calculate aerodynamic loads. The structural module is based on finite beam elements, according to Timoshenko theory, including moderate deflections. Several fixed-pitch propellers with thin-walled cross sections made of both isotropic and non-isotropic materials are investigated. The essential parameters are varied: diameter, disc loading, sweep, material, rotational, and flight velocity. The relative change of thrust between rigid and elastic blades quantifies the impact of propeller elasticity. Swept propellers of large diameters or low disc loadings can decrease the thrust significantly. High flight velocities and low material stiffness amplify this tendency. Performance calculations without consideration of propeller elasticity can lead to decreased efficiency. To avoid cost- and time-intense redesigns, propeller elasticity should be considered for swept planforms and low disc loadings.
Das vorliegende Buch dient als Grundlage für die Bachelor- und Master-Ausbildung von Studierenden im Fachgebiet Strömungslehre und Aerodynamik. Im hier behandelten Teilbereich der inkompressiblen Profile und Tragflügelaerodynamik werden schwerpunktmäßig die folgenden Themen besprochen:
- Profilaerodynamik
- Tragflügelaerodynamik
- Flugzeugpolare
- Methoden zur Flugbereichserweiterung
- Schwebeschub und Schwebeleistung
- Propellerblattaerodynamik
- Numerische Methoden zur Tragflügelberechnung
4CH TX/RX Surface Coil for 7T: Design, Optimization and Application for Cardiac Function Imaging
(2010)
Practical impediments of ultra high field cardiovascular MR (CVMR) can be catalogued in exacerbated magnetic field and radio frequency (RF) inhomogeneities, susceptibility and off-resonance effects, conductive and dielectric effects in tissue, and RF power deposition constraints, which all bear the potential to spoil the benefit of CVMR at 7T. Therefore, a four element cardiac transceive surface coil array was developed. Cardiac imaging provided clinically acceptable signal homogeneity with an excellent blood myocardium contrast. Subtle anatomic structures, such as pericardium, mitral and tricuspid valves and their apparatus, papillary muscles, and trabecles were accurately delineated.
Purpose
To design and evaluate a four-channel cardiac transceiver coil array for functional cardiac imaging at 7T.
Materials and Methods
A four-element cardiac transceiver surface coil array was developed with two rectangular loops mounted on an anterior former and two rectangular loops on a posterior former. specific absorption rate (SAR) simulations were performed and a Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-1 calibration method was applied prior to obtain 2D FLASH CINE (mSENSE, R = 2) images from nine healthy volunteers with a spatial resolution of up to 1 × 1 × 2.5 mm3.
Results
Tuning and matching was found to be better than 10 dB for all subjects. The decoupling (S21) was measured to be >18 dB between neighboring loops, >20 dB for opposite loops, and >30 dB for other loop combinations. SAR values were well within the limits provided by the IEC. Imaging provided clinically acceptable signal homogeneity with an excellent blood-myocardium contrast applying the Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-2 calibration approach.
Conclusion
A four-channel cardiac transceiver coil array for 7T was built, allowing for cardiac imaging with clinically acceptable signal homogeneity and an excellent blood-myocardium contrast. Minor anatomic structures, such as pericardium, mitral, and tricuspid valves and their apparatus, as well as trabeculae, were accurately delineated.