Refine
Year of publication
Institute
- Fachbereich Elektrotechnik und Informationstechnik (38)
- Fachbereich Luft- und Raumfahrttechnik (20)
- Fachbereich Medizintechnik und Technomathematik (13)
- Fachbereich Energietechnik (12)
- ECSM European Center for Sustainable Mobility (10)
- Fachbereich Maschinenbau und Mechatronik (9)
- Solar-Institut Jülich (6)
- Fachbereich Chemie und Biotechnologie (4)
- Fachbereich Wirtschaftswissenschaften (4)
- INB - Institut für Nano- und Biotechnologien (4)
Language
- English (105) (remove)
Document Type
- Article (63)
- Conference Proceeding (30)
- Part of a Book (5)
- Book (4)
- Conference: Meeting Abstract (2)
- Conference Poster (1)
Keywords
- Blitzschutz (2)
- Erneuerbare Energien (2)
- Hybridsystem (2)
- Lightning protection (2)
- cyber physical production system (2)
- digital shadow (2)
- humans (2)
- Actuator disk modelling (1)
- Aeroelasticity (1)
- Antarctica (1)
- Automation (1)
- BET (1)
- Blade element method (1)
- CFD propeller simulation (1)
- Centrifugal twisting moment (1)
- Enterprise Architecture (1)
- Extension–twist coupling (1)
- Fiducial marker system (1)
- Finite element method (1)
- Image Database (1)
- Image Forensics (1)
- Jupiter (1)
- Lifting propeller (1)
- Literature review (1)
- Mobile Phones (1)
- PIV calibration (1)
- Photovoltaikanlage (1)
- Planetary exploration (1)
- Propeller (1)
- Propeller aerodynamics (1)
- Propeller elasticity (1)
- Propeller performance (1)
- Recognition algorithms (1)
- Renewable energy (1)
- Research process (1)
- Robotic Process Automation (1)
- Robotics (1)
- Selective Laser Melting (SLM) (1)
- Software Robots (1)
- Text analytics (1)
- Text mining (1)
- Trapeze effect (1)
- Windenergieanlage (1)
- XML (1)
- access control (1)
- additive manufacturing (1)
- anaesthetic complications (1)
- authorization (1)
- business process automation (1)
- cobald chrome (1)
- commercial offthe- shelf solutions (1)
- concrete (1)
- containers (1)
- cyber-physical production system (1)
- dental bridges (1)
- dental trauma (1)
- difficult airway (1)
- digital twin (1)
- distribution strategy (1)
- double-lumen tube intubation (1)
- engines (1)
- framework (1)
- grid computing (1)
- history (1)
- human digital shadow (1)
- human factors (1)
- human-machine interface (1)
- hybrid system (1)
- hybrid-system (1)
- ice moons (1)
- internet of production (1)
- libraries (1)
- photovoltaic system (1)
- provenance (1)
- renewable energy (1)
- resource management (1)
- robotic process automation (1)
- scan strategy (1)
- scheduling (1)
- security (1)
- software evaluation (1)
- software selection (1)
- synchronization (1)
- underwater vehicle (1)
- user & usage (1)
- videolaryngoscopy (1)
- wind turbine (1)
- workflow (1)
- workflow management software (1)
Organization and management of German-Russian joint ventures. Bock, Jürgen; Thielemann, Frank
(1994)
Numerical algorithms with C
(1996)
Animal experiments and preliminary results in humans have indicated alterations of hippocampal muscarinic acetylcholine receptors (mAChR) in temporal lobe epilepsy. Patients with temporal lobe epilepsy often present with a reduction in hippocampal volume. The aim of this study was to investigate the influence of hippocampal atrophy on the quantification of mAChR with single photon emission tomography (SPET) in patients with temporal lobe epilepsy. Cerebral uptake of the muscarinic cholinergic antagonist [123I]4-iododexetimide (IDex) was investigated by SPET in patients suffering from temporal lobe epilepsy of unilateral (n=6) or predominantly unilateral (n=1) onset. Regions of interest were drawn on co-registered magnetic resonance images. Hippocampal volume was determined in these regions and was used to correct the SPET results for partial volume effects. A ratio of hippocampal IDex binding on the affected side to that on the unaffected side was used to detect changes in muscarinic cholinergic receptor density. Before partial volume correction a decrease in hippocampal IDex binding on the focus side was found in each patient. After partial volume no convincing differences remained. Our results indicate that the reduction in hippocampal IDex binding in patients with epilepsy is due to a decrease in hippocampal volume rather than to a decrease in receptor concentration.
Single-photon emission tomography (SPET) with the amino acid analogue l-3-[123I]iodo-α-methyl tyrosine (IMT) is helpful in the diagnosis and monitoring of cerebral gliomas. Radiolabelled amino acids seem to reflect tumour infiltration more specifically than conventional methods like magnetic resonance imaging and computed tomography. Automatic tumour delineation based on maximal tumour uptake may cause an overestimation of mean tumour uptake and an underestimation of tumour extension in tumours with circumscribed peaks. The aim of this study was to develop a program for tumour delineation and calculation of mean tumour uptake which takes into account the mean background activity and is thus optimised to the problem of tumour definition in IMT SPET. Using the frequency distribution of pixel intensities of the tomograms a program was developed which automatically detects a reference brain region and draws an isocontour region around the tumour taking into account mean brain radioactivity. Tumour area and tumour/brain ratios were calculated. A three-compartment phantom was simulated to test the program. The program was applied to IMT SPET studies of 20 patients with cerebral gliomas and was compared to the results of manual analysis by three different investigators. Activity ratios and chamber extension of the phantom were correctly calculated by the automatic analysis. A method based on image maxima alone failed to determine chamber extension correctly. Manual region of interest analysis in patient studies resulted in a mean inter-observer standard deviation of 8.7%±6.1% (range 2.7%–25.0%). The mean value of the results of the manual analysis showed a significant correlation to the results of the automatic analysis (r = 0.91, P<0.0001 for the uptake ratio; r = 0.87, P<0.0001 for the tumour area). We conclude that the algorithm proposed simplifies the calculation of uptake ratios and may be used for observer-independent evaluation of IMT SPET studies. Three-dimensional tumour recognition and transfer to co-registered morphological images based on this program may be useful for the planning of surgical and radiation treatment.
Lightning protection design of a renewable energy hybrid-system without power mains connection
(2001)
Lightning protection design of a renewable energy hybrid-system without power mains connection
(2001)
In the year 2000 a direct lightning strike to the hybridsystem without power mains connection VATALI on the Greek island Crete results in the destruction and damage of some mechanical and electrical components. The hybrid-system VATALI was not lightning protected at that time. The hardware damage costs are approx. 60,000 €. The exposed site of the hybrid-system on top of a mountain was and still is the reason for a high risk of lightning strikes. Also in the future further lightning strikes have to be taken into consideration. In the paper a fundamental lightning protection design concept for renewable energy hybrid-systems without power mains connection and protection measures against direct strikes and overvoltages are shown in detail. The design concept was realized exemplarily for the hybrid-system VATALI. The hardware costs for the protection measures were about 15,000 €. About 50% of the costs are due to protection measures against direct strikes, 50% are due to overvoltage protection. Future extensions, new installations, or modifications have to be included into the lightning protection design concept of the hybrid-system.
In the paper a lightning protection design concept for renewable energy hybrid-systems without power mains connection is described. Based on a risk analysis protection measures against direct strikes and overvoltages are shown in an overview. The design concept is realized exemplarily for the hybrid-system VATALI on the Greek island Crete. VATALI, not lightning protected at that time, was a victim of a lightning strike in the year 2000 causing destructions and damages of some mechanical and electrical components with costs of approx. 60.000 €. The hardware costs for the protection measures were about 15.000 €: about 50% of the costs are due to protection measures against direct strikes, 50% are due to overvoltage protection.