Refine
Year of publication
Institute
- Fachbereich Energietechnik (57)
- Fachbereich Elektrotechnik und Informationstechnik (56)
- Fachbereich Luft- und Raumfahrttechnik (21)
- Solar-Institut Jülich (17)
- Fachbereich Medizintechnik und Technomathematik (12)
- ECSM European Center for Sustainable Mobility (10)
- Fachbereich Maschinenbau und Mechatronik (8)
- Fachbereich Wirtschaftswissenschaften (5)
- IfB - Institut für Bioengineering (4)
- INB - Institut für Nano- und Biotechnologien (3)
Has Fulltext
- no (184) (remove)
Document Type
- Article (93)
- Conference Proceeding (38)
- Book (31)
- Part of a Book (17)
- Conference: Meeting Abstract (2)
- Bachelor Thesis (1)
- Patent (1)
- Report (1)
Keywords
- Literaturanalyse (3)
- Digitale Transformation (2)
- Digitalisierung (2)
- Forschungsprozess (2)
- Robotic Process Automation (2)
- Text Analytics (2)
- cyber physical production system (2)
- digital shadow (2)
- Antarctica (1)
- Arbeit 4.0 (1)
- Chatbots (1)
- Customer Experience Management (1)
- Customer Journeys (1)
- E-Learning (1)
- EBSCO Discovery Service (1)
- Emotional (1)
- Enterprise Architecture (1)
- Forschung (1)
- Forschungsinformationssystem (1)
- Fotografie (1)
- Fühlen (1)
- Geschäftsmodelle (1)
- IBM Watson Explorer (1)
- Image Database (1)
- Image Forensics (1)
- Informationsgetriebene Geschäftsmodelle (1)
- Intelligentes Parken (1)
- Internet der Dinge (1)
- Jupiter (1)
- Kommerzielle Interaktionen (1)
- Literatur-analyse-prozess (1)
- Literaturdaten (1)
- Literature review (1)
- Literaturrecherche (1)
- Mobile Phones (1)
- Monetarisierung (1)
- Planetary exploration (1)
- Portrait (1)
- Prozessagilität (1)
- Prozessautomatisierung (1)
- Qualitative Wertschöpfungsanalyse (1)
- Research process (1)
- Serviceintegration (1)
- Software Robots (1)
- Text Analytics (1)
- Text Mining (1)
- Text analytics (1)
- Text mining (1)
- Unternehmensarchitekturen (1)
- Unternehmensarchitekturen Internet der Dinge (1)
- Weiblicher Blick (1)
- Wertschöpfungskettenanalyse (1)
- Wissenstransfer (1)
- anaesthetic complications (1)
- business process automation (1)
- commercial offthe- shelf solutions (1)
- cyber-physical production system (1)
- dental trauma (1)
- difficult airway (1)
- digital twin (1)
- double-lumen tube intubation (1)
- human digital shadow (1)
- human factors (1)
- human-machine interface (1)
- ice moons (1)
- internet of production (1)
- robotic process automation (1)
- software evaluation (1)
- software selection (1)
- underwater vehicle (1)
- user & usage (1)
- videolaryngoscopy (1)
Numerical algorithms with C
(1996)
Kompetenz zur Innovation: Vom Druckbetrieb zum Multimedia-Dienstleister . Staudt, E.; Thielemann, F.
(1997)
Animal experiments and preliminary results in humans have indicated alterations of hippocampal muscarinic acetylcholine receptors (mAChR) in temporal lobe epilepsy. Patients with temporal lobe epilepsy often present with a reduction in hippocampal volume. The aim of this study was to investigate the influence of hippocampal atrophy on the quantification of mAChR with single photon emission tomography (SPET) in patients with temporal lobe epilepsy. Cerebral uptake of the muscarinic cholinergic antagonist [123I]4-iododexetimide (IDex) was investigated by SPET in patients suffering from temporal lobe epilepsy of unilateral (n=6) or predominantly unilateral (n=1) onset. Regions of interest were drawn on co-registered magnetic resonance images. Hippocampal volume was determined in these regions and was used to correct the SPET results for partial volume effects. A ratio of hippocampal IDex binding on the affected side to that on the unaffected side was used to detect changes in muscarinic cholinergic receptor density. Before partial volume correction a decrease in hippocampal IDex binding on the focus side was found in each patient. After partial volume no convincing differences remained. Our results indicate that the reduction in hippocampal IDex binding in patients with epilepsy is due to a decrease in hippocampal volume rather than to a decrease in receptor concentration.
Druckindustrielle Innovation
(1998)
Mit vereinten Kräften
(1998)
Single-photon emission tomography (SPET) with the amino acid analogue l-3-[123I]iodo-α-methyl tyrosine (IMT) is helpful in the diagnosis and monitoring of cerebral gliomas. Radiolabelled amino acids seem to reflect tumour infiltration more specifically than conventional methods like magnetic resonance imaging and computed tomography. Automatic tumour delineation based on maximal tumour uptake may cause an overestimation of mean tumour uptake and an underestimation of tumour extension in tumours with circumscribed peaks. The aim of this study was to develop a program for tumour delineation and calculation of mean tumour uptake which takes into account the mean background activity and is thus optimised to the problem of tumour definition in IMT SPET. Using the frequency distribution of pixel intensities of the tomograms a program was developed which automatically detects a reference brain region and draws an isocontour region around the tumour taking into account mean brain radioactivity. Tumour area and tumour/brain ratios were calculated. A three-compartment phantom was simulated to test the program. The program was applied to IMT SPET studies of 20 patients with cerebral gliomas and was compared to the results of manual analysis by three different investigators. Activity ratios and chamber extension of the phantom were correctly calculated by the automatic analysis. A method based on image maxima alone failed to determine chamber extension correctly. Manual region of interest analysis in patient studies resulted in a mean inter-observer standard deviation of 8.7%±6.1% (range 2.7%–25.0%). The mean value of the results of the manual analysis showed a significant correlation to the results of the automatic analysis (r = 0.91, P<0.0001 for the uptake ratio; r = 0.87, P<0.0001 for the tumour area). We conclude that the algorithm proposed simplifies the calculation of uptake ratios and may be used for observer-independent evaluation of IMT SPET studies. Three-dimensional tumour recognition and transfer to co-registered morphological images based on this program may be useful for the planning of surgical and radiation treatment.
Die Anfertigung wissenschaftlicher Arbeiten und ihre Präsentation - ein komprimierter Einstieg
(1999)
Lightning protection design of a renewable energy hybrid-system without power mains connection
(2001)
Textile reinforced concrete. Part I: Process model for collaborative research and development
(2003)
Comparison of solar hot water systems in solar settlements - decentralized or centralized systems?
(2004)
Media Delivery Based on Service Aware Transport Overlay Networks / Kampmann, Markus ; Hartung, Frank
(2007)
4CH TX/RX Surface Coil for 7T: Design, Optimization and Application for Cardiac Function Imaging
(2010)
Practical impediments of ultra high field cardiovascular MR (CVMR) can be catalogued in exacerbated magnetic field and radio frequency (RF) inhomogeneities, susceptibility and off-resonance effects, conductive and dielectric effects in tissue, and RF power deposition constraints, which all bear the potential to spoil the benefit of CVMR at 7T. Therefore, a four element cardiac transceive surface coil array was developed. Cardiac imaging provided clinically acceptable signal homogeneity with an excellent blood myocardium contrast. Subtle anatomic structures, such as pericardium, mitral and tricuspid valves and their apparatus, papillary muscles, and trabecles were accurately delineated.
Purpose
To design and evaluate a four-channel cardiac transceiver coil array for functional cardiac imaging at 7T.
Materials and Methods
A four-element cardiac transceiver surface coil array was developed with two rectangular loops mounted on an anterior former and two rectangular loops on a posterior former. specific absorption rate (SAR) simulations were performed and a Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-1 calibration method was applied prior to obtain 2D FLASH CINE (mSENSE, R = 2) images from nine healthy volunteers with a spatial resolution of up to 1 × 1 × 2.5 mm3.
Results
Tuning and matching was found to be better than 10 dB for all subjects. The decoupling (S21) was measured to be >18 dB between neighboring loops, >20 dB for opposite loops, and >30 dB for other loop combinations. SAR values were well within the limits provided by the IEC. Imaging provided clinically acceptable signal homogeneity with an excellent blood-myocardium contrast applying the Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-2 calibration approach.
Conclusion
A four-channel cardiac transceiver coil array for 7T was built, allowing for cardiac imaging with clinically acceptable signal homogeneity and an excellent blood-myocardium contrast. Minor anatomic structures, such as pericardium, mitral, and tricuspid valves and their apparatus, as well as trabeculae, were accurately delineated.
Inkompressible Strömungen
(2012)
With its need for high SNR and short acquisition times, Cardiac MRI (CMR) is an intriguing target application for ultrahigh field MRI. Due to the sheer size of the upper torso, however, the known RF issues of 7T MRI are also most prominent in CMR. Recent years brought substantial progress but the full potential of the ultrahigh field for CMR is yet to be exploited. Parallel transmission (pTx) is a promising approach in this context and several groups have already reported B1 shimming for 7T CMR. In such a static pTx application amplitudes and phases of all Tx channels are adjusted individually but otherwise imaging techniques established in current clinical practice 1.5 T and 3 T are applied. More advanced forms of pTx as spatially selective excitation (SSE) using Transmit SENSE promise additional benefits like faster imaging with reduced fields of view or improved SAR control. SSE requires the full dynamic capabilities of pTx, however, and for the majority of today's implemented pTx hardware the internal synchronization of the Tx array does not easily permit external triggering as needed for CMR. Here we report a software solution to this problem and demonstrate the feasibility of CINE CMR at 7 T using a Tx array.