Refine
Year of publication
Institute
- Fachbereich Energietechnik (57)
- Fachbereich Elektrotechnik und Informationstechnik (56)
- Fachbereich Luft- und Raumfahrttechnik (21)
- Solar-Institut Jülich (17)
- Fachbereich Medizintechnik und Technomathematik (14)
- ECSM European Center for Sustainable Mobility (10)
- Fachbereich Maschinenbau und Mechatronik (8)
- Fachbereich Wirtschaftswissenschaften (5)
- INB - Institut für Nano- und Biotechnologien (4)
- IfB - Institut für Bioengineering (4)
Has Fulltext
- no (186) (remove)
Document Type
- Article (95)
- Conference Proceeding (38)
- Book (31)
- Part of a Book (17)
- Conference: Meeting Abstract (2)
- Bachelor Thesis (1)
- Patent (1)
- Report (1)
Keywords
- Literaturanalyse (3)
- Digitale Transformation (2)
- Digitalisierung (2)
- Forschungsprozess (2)
- Robotic Process Automation (2)
- Text Analytics (2)
- cyber physical production system (2)
- digital shadow (2)
- Antarctica (1)
- Arbeit 4.0 (1)
- Chatbots (1)
- Customer Experience Management (1)
- Customer Journeys (1)
- E-Learning (1)
- EBSCO Discovery Service (1)
- Emotional (1)
- Enterprise Architecture (1)
- Forschung (1)
- Forschungsinformationssystem (1)
- Fotografie (1)
- Fühlen (1)
- Geschäftsmodelle (1)
- IBM Watson Explorer (1)
- Image Database (1)
- Image Forensics (1)
- Informationsgetriebene Geschäftsmodelle (1)
- Intelligentes Parken (1)
- Internet der Dinge (1)
- Jupiter (1)
- Kommerzielle Interaktionen (1)
- Literatur-analyse-prozess (1)
- Literaturdaten (1)
- Literature review (1)
- Literaturrecherche (1)
- Mobile Phones (1)
- Monetarisierung (1)
- Planetary exploration (1)
- Portrait (1)
- Prozessagilität (1)
- Prozessautomatisierung (1)
- Qualitative Wertschöpfungsanalyse (1)
- Research process (1)
- Selective Laser Melting (SLM) (1)
- Serviceintegration (1)
- Software Robots (1)
- Text Analytics (1)
- Text Mining (1)
- Text analytics (1)
- Text mining (1)
- Unternehmensarchitekturen (1)
- Unternehmensarchitekturen Internet der Dinge (1)
- Weiblicher Blick (1)
- Wertschöpfungskettenanalyse (1)
- Wissenstransfer (1)
- XML (1)
- additive manufacturing (1)
- anaesthetic complications (1)
- business process automation (1)
- cobald chrome (1)
- commercial offthe- shelf solutions (1)
- concrete (1)
- containers (1)
- cyber-physical production system (1)
- dental bridges (1)
- dental trauma (1)
- difficult airway (1)
- digital twin (1)
- double-lumen tube intubation (1)
- framework (1)
- history (1)
- human digital shadow (1)
- human factors (1)
- human-machine interface (1)
- humans (1)
- ice moons (1)
- internet of production (1)
- libraries (1)
- provenance (1)
- robotic process automation (1)
- scan strategy (1)
- software evaluation (1)
- software selection (1)
- synchronization (1)
- underwater vehicle (1)
- user & usage (1)
- videolaryngoscopy (1)
- workflow (1)
Textile reinforced concrete. Part I: Process model for collaborative research and development
(2003)
Comparison of solar hot water systems in solar settlements - decentralized or centralized systems?
(2004)
Media Delivery Based on Service Aware Transport Overlay Networks / Kampmann, Markus ; Hartung, Frank
(2007)
4CH TX/RX Surface Coil for 7T: Design, Optimization and Application for Cardiac Function Imaging
(2010)
Practical impediments of ultra high field cardiovascular MR (CVMR) can be catalogued in exacerbated magnetic field and radio frequency (RF) inhomogeneities, susceptibility and off-resonance effects, conductive and dielectric effects in tissue, and RF power deposition constraints, which all bear the potential to spoil the benefit of CVMR at 7T. Therefore, a four element cardiac transceive surface coil array was developed. Cardiac imaging provided clinically acceptable signal homogeneity with an excellent blood myocardium contrast. Subtle anatomic structures, such as pericardium, mitral and tricuspid valves and their apparatus, papillary muscles, and trabecles were accurately delineated.
Additive Manufacturing of metal parts by Selective Laser Melting has become a powerful tool for the direct manufacturing of complex parts mainly for the aerospace and medical industry. With the introduction of its desktop machine, Realizer targeted the dental market. The contribution describes the special features of the machine, discusses details of the process and shows manufacturing results focused on metal dental devices.
The importance of validating and reproducing the outcome of computational processes is fundamental to many application domains. Assuring the provenance of workflows will likely become even more important with respect to the incorporation of human tasks to standard workflows by emerging standards such as WS-HumanTask. This paper addresses this trend by an actor-based workflow approach that actively support provenance. It proposes a framework to track and store provenance information automatically that applies for various workflow management systems. In particular, the introduced provenance framework supports the documentation of workflows in a legally binding way. The authors therefore use the concept of layered XML documents, i.e. history-tracing XML. Furthermore, the proposed provenance framework enables the executors (actors) of a particular workflow task to attest their operations and the associated results by integrating digital XML signatures.
Purpose
To design and evaluate a four-channel cardiac transceiver coil array for functional cardiac imaging at 7T.
Materials and Methods
A four-element cardiac transceiver surface coil array was developed with two rectangular loops mounted on an anterior former and two rectangular loops on a posterior former. specific absorption rate (SAR) simulations were performed and a Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-1 calibration method was applied prior to obtain 2D FLASH CINE (mSENSE, R = 2) images from nine healthy volunteers with a spatial resolution of up to 1 × 1 × 2.5 mm3.
Results
Tuning and matching was found to be better than 10 dB for all subjects. The decoupling (S21) was measured to be >18 dB between neighboring loops, >20 dB for opposite loops, and >30 dB for other loop combinations. SAR values were well within the limits provided by the IEC. Imaging provided clinically acceptable signal homogeneity with an excellent blood-myocardium contrast applying the Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-2 calibration approach.
Conclusion
A four-channel cardiac transceiver coil array for 7T was built, allowing for cardiac imaging with clinically acceptable signal homogeneity and an excellent blood-myocardium contrast. Minor anatomic structures, such as pericardium, mitral, and tricuspid valves and their apparatus, as well as trabeculae, were accurately delineated.
Inkompressible Strömungen
(2012)
With its need for high SNR and short acquisition times, Cardiac MRI (CMR) is an intriguing target application for ultrahigh field MRI. Due to the sheer size of the upper torso, however, the known RF issues of 7T MRI are also most prominent in CMR. Recent years brought substantial progress but the full potential of the ultrahigh field for CMR is yet to be exploited. Parallel transmission (pTx) is a promising approach in this context and several groups have already reported B1 shimming for 7T CMR. In such a static pTx application amplitudes and phases of all Tx channels are adjusted individually but otherwise imaging techniques established in current clinical practice 1.5 T and 3 T are applied. More advanced forms of pTx as spatially selective excitation (SSE) using Transmit SENSE promise additional benefits like faster imaging with reduced fields of view or improved SAR control. SSE requires the full dynamic capabilities of pTx, however, and for the majority of today's implemented pTx hardware the internal synchronization of the Tx array does not easily permit external triggering as needed for CMR. Here we report a software solution to this problem and demonstrate the feasibility of CINE CMR at 7 T using a Tx array.