Armiranobetonske (AB) zgrade sa zidanom ispunom
se izvode u mnogim zemljama širom sveta. Iako se
zidana ispuna posmatra kao nekonstruktivni element, ona
značajno utiče na promenu dinamičkih karakteristika AB
ramovskih konstrukcija u toku zemljotresnog dejstva.
Odskora, značajan napor je utrošen na istraživanje
izolovanih ispuna, koje su odvojene od okolnog rama
obično ostavljanjem prostora između rama i ispune. U
ovom slučaju deformacija rama ne aktivira ispunu i na taj
način ispuna ne utiče na ponašanje rama. Ovaj rad
predstavlja rezultate istraživanja ponašanja AB
ramovskih zgrada sa INODIS sistemom koji izoluje ispunu
u odnosu na okolni ram. Uticaj izolovane ispune je prvo
ispitan na jednospratnim i jednobrodnim ramovima. Ovo
je iskorišćeno kao osnova za parametarsku analizu na
višespratnim i višebrodnim ramovima, kao i na primeru
zgrade. Promena krutosti i dinamičkih karakteristika je
analizirano kao i odgovor pri zemljotresnom dejstvu.
Izvršeno je poređenje sa praznom ramovskom
konstrukcijom kao i ramovima ispunjenim ispunom na
tradicionalni način. Rezultati pokazuju da je ponašanje
ramova sa izolovanom ispunom slično ponašanju praznih
ramova, dok je ponašanje ramova sa tradicionalnom
ispunom daleko drugačije i zahteva kompleksne
numeričke modele. Ovo znači da ukoliko se primeni
adekvatna konstruktivna mera izolacije ispune, proračun
ramovskim zgrada sa zidanom ispunom se može
značajno pojednostaviti.
Past earthquakes demonstrated the high vulnerability of industrial facilities equipped with complex process technologies leading to serious damage of process equipment and multiple and simultaneous release of hazardous substances. Nonetheless, current standards for seismic design of industrial facilities are considered inadequate to guarantee proper safety conditions against exceptional events entailing loss of containment and related consequences. On these premises, the SPIF project -Seismic Performance of Multi-Component Systems in Special Risk Industrial Facilities- was proposed within the framework of the European H2020 SERA funding scheme. In detail, the objective of the SPIF project is the investigation of the seismic behaviour of a representative industrial multi-storey frame structure equipped with complex process components by means of shaking table tests. Along this main vein and in a performance-based design perspective, the issues investigated in depth are the interaction between a primary moment resisting frame (MRF) steel structure and secondary process components that influence the performance of the whole system; and a proper check of floor spectra predictions. The evaluation of experimental data clearly shows a favourable performance of the MRF structure, some weaknesses of local details due to the interaction between floor crossbeams and process components and, finally, the overconservatism of current design standards w.r.t. floor spectra predictions.
Because of simple construction process, high energy efficiency, significant fire resistance and excellent sound isolation, masonry infilled reinforced concrete (RC) frame structures are very popular in most of the countries in the world, as well as in seismic active areas. However, many RC frame structures with masonry infills were seriously damaged during earthquake events, as the traditional infills are generally constructed with direct contact to the RC frame which brings undesirable infill/frame interaction. This interaction leads to the activation of the equivalent diagonal strut in the infill panel, due to the RC frame deformation, and combined with seismically induced loads perpendicular to the infill panel often causes total collapses of the masonry infills and heavy damages to the RC frames. This fact was the motivation for developing different approaches for improving the behaviour of masonry infills, where infill isolation (decoupling) from the frame has been more intensively studied in the last decade. In-plane isolation of the infill wall reduces infill activation, but causes the need for additional measures to restrain out-of-plane movements. This can be provided by installing steel anchors, as proposed by some researchers. Within the framework of European research project INSYSME (Innovative Systems for Earthquake Resistant Masonry Enclosures in Reinforced Concrete Buildings) the system based on a use of elastomers for in-plane decoupling and steel anchors for out-of-plane restrain was tested. This constructive solution was tested and deeply investigated during the experimental campaign where traditional and decoupled masonry infilled RC frames with anchors were subjected to separate and combined in-plane and out-of-plane loading. Based on a detailed evaluation and comparison of the test results, the performance and effectiveness of the developed system are illustrated.
Im Rahmen des europäischen Verbundprojekts INSYSME wurden von den deutschen Partnern die Systeme IMES und INODIS zur Verbesserung des seismischen Verhaltens von ausgefachten Stahlbetonrahmen entwickelt. Ziel beider Systeme ist es, Stahlbetonrahmen und Ausfachung zu entkoppeln, anstatt die Tragfähigkeit durch aufwendige und kostspielige zusätzliche Bewehrungseinlagen zu erhöhen. Erste Ergebnisse des Systems IMES für Belastungen in und senkrecht zu der Wandebene werden vorgestellt.
Im Rahmen des europäischen Verbundprojekts INSYSME wurden von den deutschen Partnern die Systeme IMES und INODIS zur Verbesserung des seismischen Verhaltens von ausgefachten Stahlbetonrahmen entwickelt. Ziel beider Systeme ist es, Stahlbetonrahmen und Ausfachung zu entkoppeln, anstatt die Tragfähigkeit durch aufwendige und kostspielige zusätzliche Bewehrungseinlagen zu erhöhen. Erste Ergebnisse des Systems IMES für Belastungen in und senkrecht zu der Wandebene werden vorgestellt.
Influence of slab deflection on the out-of-plane capacity of unreinforced masonry partition walls
(2023)
Severe damage of non-structural elements is noticed in previous earthquakes, causing high economic losses and posing a life threat for the people. Masonry partition walls are one of the most commonly used non-structural elements. Therefore, their behaviour under earthquake loading in out-of-plane (OOP) direction is investigated by several researches in the past years. However, none of the existing experimental campaigns or analytical approaches consider the influence of prior slab deflection on OOP response of partition walls. Moreover, none of the existing construction techniques for the connection of partition walls with surrounding reinforced concrete (RC) is investigated for the combined slab deflection and OOP loading. However, the inevitable time-dependent behaviour of RC slabs leads to high values of final slab deflections which can further influence boundary conditions of partition walls. Therefore, a comprehensive study on the influence of slab deflection on the OOP capacity of masonry partitions is conducted. In the first step, experimental tests are carried out. Results of experimental tests are further used for the calibration of the numerical model employed for a parametric study. Based on the results, behaviour under combined loading for different construction techniques is explained. The results show that slab deflection leads either to severe damage or to a high reduction of OOP capacity. Existing practical solutions do not account for these effects. In this contribution, recommendations to overcome the problems of combined slab deflection and OOP loading on masonry partition walls are given. Possible interaction of in-plane (IP) loading, with the combined slab deflection and OOP loading on partition walls, is not investigated in this study.