Refine
Year of publication
Document Type
- Article (39)
- Conference Proceeding (16)
- Part of a Book (8)
- Patent (6)
- Book (2)
- Report (2)
Keywords
- Biorefinery (2)
- Analytics (1)
- Bioeconomy (1)
- Bioethanol (1)
- Biofuel (1)
- Biorefinery definitions (1)
- Butanol (1)
- Clostridium acetobutylicum (1)
- Decentral (1)
- Introduction (1)
- Lignocellulose (1)
- Lignocellulose feedstook (1)
- Mechanical (1)
- On-site (1)
- Pre-treatment (1)
- Process schemes (1)
- Renewable resources (1)
Durch die Kombination von Oligonukleotid-Liganden (Aptameren) hoher Bindungsaffinitäten
mit hochselektiv abtrennbaren magnetisierbaren Mikropartikeln
wird eine einstufige Separation von Zielmolekülen aus mikrobiologischen
Produktionsansätzen möglich. Die Aptamere werden hierfür reversibel
auf den Partikeloberflächen gebunden und für die spezifische Isolierung von
Bioprodukten eingesetzt. Die Abtrennung der beladenen Partikel erfolgt
durch einen neuen Rotor-Stator-Separator mit Hochgradient-Magnetfeld.
In Anbetracht des zu erwartenden Rückgangs der Verfügbarkeit fossiler Rohstoffe müssen nicht nur für den Energiesektor, sondern auch für die Herstellung industrieller Produkte alternative Rohstoffe gefunden werden. Ein Beispiel für einen nicht in Nahrungsmittelkonkurrenz stehenden nachwachsenden Rohstoff ist grüne Biomasse wie Gras und Klee. Diese lassen sich in Deutschland auf großen Flächen anbauen und enthalten eine Vielzahl potenzieller Substrate für Fermentationen.
For the successful implementation of microfluidic reaction systems, such as PCR and electrophoresis, the movement of small liquid volumes is essential. In conventional lab-on-a-chip-platforms, solvents and samples are passed through defined microfluidic channels with complex flow control installations. The droplet actuation platform presented here is a promising alternative. With it, it is possible to move a liquid drop (microreactor) on a planar surface of a reaction platform (lab-in-a-drop). The actuation of microreactors on the hydrophobic surface of the platform is based on the use of magnetic forces acting on the outer shell of the liquid drops which is made of a thin layer of superhydrophobic magnetite particles. The hydrophobic surface of the platform is needed to avoid any contact between the liquid core and the surface to allow a smooth movement of the microreactor. On the platform, one or more microreactors with volumes of 10 µL can be positioned and moved simultaneously. The platform itself consists of a 3 x 3 matrix of electrical double coils which accommodate either neodymium or iron cores. The magnetic field gradients are automatically controlled. By variation of the magnetic field gradients, the microreactors' magnetic hydrophobic shell can be manipulated automatically to move the microreactor or open the shell reversibly. Reactions of substrates and corresponding enzymes can be initiated by merging the microreactors or bringing them into contact with surface immobilized catalysts.
The composition of plant biomass varies depending on the feedstock and pre-treatment conditions and influences its processing in biorefineries. In order to ensure optimal process conditions, the quantitative proportion of the main polymeric components of the pre-treated biomass has to be determined. Current standard procedures for biomass compositional analysis are complex, the measurements are afflicted with errors and therefore often not comparable. Hence, new powerful analytical methods are urgently required to characterize biomass. In this contribution, Differential Scanning Calorimetry (DSC) was applied in combination with multivariate data analysis (MVA) to detect the cellulose content of the plant biomass pretreated by Liquid Hot Water (LHW) and Organosolv processes under various conditions. Unlike conventional techniques, the developed analytic method enables the accurate quantification of monosaccharide content of the plant biomass without any previous sample preparation. It is easy to handle and avoids errors in sample preparation.
An immunochromatographic lateral flow dipstick assay for the fast detection of microcystin-LR was developed. Colloid gold particles with diameters of 40 nm were used as red-colored antibody labels for the visual detection of the antigen. The new dipstick sensor is capable of detecting down to 5 µg·l−1 (ppb; total inversion of the color signal) or 1 ppb (observation of color grading) of microcystin-LR. The course of the labeling reaction was observed via spectrometric wave shifts caused by the change of particle size during the binding of antibodies. Different stabilizing reagents showed that especially bovine serum albumin (BSA) and casein increase the assays sensitivity and the conjugate stability. Performance of the dipsticks was quantified by pattern processing of capture zone CCD images. Storage stability of dipsticks and conjugate suspensions over 115 days under different conditions were monitored. The ready-to-use dipsticks were successfully tested with microcystin-LR-spiked samples of outdoor drinking- and salt water and applied to the tissue of microcystin-fed mussels.
Nitratfreie Molke
(2009)
Characterization and evaluation of lignocellulosic biomass 130 hydrolysates for ABE fermentation
(2016)
Die vorliegende Erfindung betrifft eine Vorrichtung und ein Verfahren zur Bestimmung des Kontaktwinkels eines flüssigen oder mit Flüssigkeit gefüllten Körpers. Dieser besteht aus einem Träger (1) und einer damit verbundenen, in einem Winkelbereich von mehr als 0° bis maximal 90° neigbaren Ebene (8) mit einer darin ausgebildeten Abrollbahn (9) für den flüssigen oder mit Flüssigkeit gefüllten Körper. An der Ebene (8) sind mehrere Sensoren (11, 12) zur Erfassung der Rolldauer des Körpers entlang der Rollstrecke angeordnet. Erfindungsgemäß ist vorgesehen, dass die Einstellung des Neigungswinkels der Ebene (8) über ein Winkelmessgerät (10) erfolgt, wodurch ein Abrollwinkel erfassbar ist, bei dem der Körper in Bewegung gerät. Aus der Rolldauer, der Rollstrecke und dem Abrollwinkel wird der Kontaktwinkel des Körpers ermittelt.
The invention relates to a system for the implementation of chemical, biological or physical reactions, consisting of - one or more magnetic micro-reactors, each comprising a shell made of hydrophobic magnetic nanoparticles encapsulating an aqueous core, - a plane platform comprising a surface to receive the micro-reactors, - a source that generates a magnetic field above or underneath the platform for manipulating the one or more hydrophobic magnetic micro-reactors, or for moving them along the surface of the platform from one position to another position, characterized in that the aqueous core of the one or more magnetic micro-reactors contains a reaction solution or buffer, and wherein the magnetic field generated by the source correlates to a defined position on the surface of the platform.