Refine
Year of publication
Institute
- Fachbereich Elektrotechnik und Informationstechnik (13)
- Solar-Institut Jülich (10)
- Fachbereich Luft- und Raumfahrttechnik (8)
- Fachbereich Energietechnik (7)
- Fachbereich Maschinenbau und Mechatronik (6)
- ECSM European Center for Sustainable Mobility (3)
- Fachbereich Bauingenieurwesen (1)
- Fachbereich Wirtschaftswissenschaften (1)
- IfB - Institut für Bioengineering (1)
Document Type
- Conference Proceeding (46) (remove)
Keywords
- Blitzschutz (3)
- Lightning protection (3)
- Erneuerbare Energien (2)
- Hybridsystem (2)
- cyber physical production system (2)
- digital shadow (2)
- photovoltaic system (2)
- wind turbine (2)
- Antarctica (1)
- Digitale Transformation (1)
Is part of the Bibliography
- no (46)
Ein von der Arbeitsgemeinschaft (AG) Solar NRW und diversen Industriepartnern gefördertes und an der Fachhochschule Aachen, Abt. Jülich durchgeführtes Forschungsprojekt „Blitzschutz für netz-autarke Hybridanlagen“ machte es möglich, sich mit dem Blitzschutz speziell solcher Anlagen näher zu beschäftigen. Vermehrt bekannt gewordene Schadensfälle an nicht netz-gekoppelten Hybridanlagen waren der Auslöser, den Schutz zu überdenken. Definiertes Ziel war es, für netz-autarke energietechnische Anlagen ein Konzept zum Schutz vor Blitzeinwirkungen zu erstellen. Diese Anlagen bestehen üblicherweise aus einer oder mehreren Photovoltaikanlagen, ggf. auch Solarthermieanlagen und einem oder mehreren kleineren Windgeneratoren (sie werden deshalb auch als Hybridanlagen bezeichnet). Zur Erhöhung der Versorgungssicherheit kann noch ein Dieselaggregat dazukommen. Hybridanlagen werden vor allem in Gebieten mit sehr schlechter öffentlicher Energieversorgung eingesetzt, d.h. insbesondere in relativ dünn bewohnten Gebieten und in Entwicklungsländern. Dem Blitzschutz von Hybridanlagen kommt dabei eine steigende Bedeutung zu. Besonderes Augenmerk in dem genannten Forschungsprojekt sollte dabei auf die technisch/wirtschaftliche Ausgewogenheit des Schutzes gelegt werden: • die Schutzmaßnahmen sollen nur in solchen Fällen eingesetzt werden, wo dies als Ergebnis von Risikoanalysen sinnvoll erscheint; • für typische netz-autarke Hybridanlagen sollen die Schutzmaßnahmen ohne deutliche Verteuerung realisierbar sein (es soll also kein absoluter Schutz realisiert werden; ggf. soll lediglich der auftretende Schaden soweit möglich minimiert werden). Dazu wurde in einem ersten Schritt zunächst eine Aufnahme des Iststandes einiger typischer netz-autarker Hybridanlagen und deren einzelnen Komponenten durchgeführt. Aufgrund dessen wurde eine umfassende Risikoanalyse zur Blitzbedrohung dieser Anlagen auf der Basis von VDE V 0185 Teil 2:2002-11 [1] erstellt. Die Ergebnisse mündeten in ein technisch/wirtschaftlich ausgewogenes Konzept für den Anlagen- Blitzschutz (d.h. insbesondere dem Schutz vor direkten Blitzeinschlägen und deren unmittelbaren Auswirkungen) nach VDE V 0185 Teil 3:2002-11 [2] und für den Elektronik-Blitzschutz (d.h. für den Schutz vor Überspannungen durch direkte, insbesondere aber auch indirekte Blitzeinschläge) nach VDE V 0185 Teil 4:2002-11 [3]. Aufgrund der gesammelten Ergebnisse konnten dabei allgemeine Empfehlungen für den Äußeren und Inneren Blitzschutz von regenerativen Energieerzeugungssystemen erstellt werden. Diese sollen in Schulungen einmünden, die für Hersteller und Betreiber von Hybridanlagen angeboten werden. Durch die Anwendung wird der Schutz der Anlagen vor Blitzeinwirkung und elektromagnetischen Störungen verbessert, was sich in einer reduzierten Ausfallwahrscheinlichkeit bzw. erhöhten Verfügbarkeit wiederspiegelt. An einigen ausgewählten Anlagen werden mit Hilfe der im Projekt involvierten Industriepartner die Schutzmaßnahmen realisiert. Hierbei entstanden den Eigentümern bzw. Betreibern der Anlagen keine Kosten. In diesem Beitrag werden beispielhaft drei Anlagenprojekte detailliert gezeigt. Es handelt sich dabei um eine Schweinezuchtfarm in Magallón (Spanien, Zaragozza), das bioklimatische Haus (Kreta, Heraklion) und die Tegernseer- Hütte (Deutschland, Lenggries).
In the paper a lightning protection design concept for renewable energy hybrid-systems without power mains connection is described. Based on a risk analysis protection measures against direct strikes and overvoltages are shown in an overview. The design concept is realized exemplarily for the hybrid-system VATALI on the Greek island Crete. VATALI, not lightning protected at that time, was a victim of a lightning strike in the year 2000 causing destructions and damages of some mechanical and electrical components with costs of approx. 60.000 €. The hardware costs for the protection measures were about 15.000 €: about 50% of the costs are due to protection measures against direct strikes, 50% are due to overvoltage protection.
Lightning protection design of a renewable energy hybrid-system without power mains connection
(2001)
In the year 2000 a direct lightning strike to the hybridsystem without power mains connection VATALI on the Greek island Crete results in the destruction and damage of some mechanical and electrical components. The hybrid-system VATALI was not lightning protected at that time. The hardware damage costs are approx. 60,000 €. The exposed site of the hybrid-system on top of a mountain was and still is the reason for a high risk of lightning strikes. Also in the future further lightning strikes have to be taken into consideration. In the paper a fundamental lightning protection design concept for renewable energy hybrid-systems without power mains connection and protection measures against direct strikes and overvoltages are shown in detail. The design concept was realized exemplarily for the hybrid-system VATALI. The hardware costs for the protection measures were about 15,000 €. About 50% of the costs are due to protection measures against direct strikes, 50% are due to overvoltage protection. Future extensions, new installations, or modifications have to be included into the lightning protection design concept of the hybrid-system.
Physische Prototypen, also Anschauungs- und Funktionsmodelle nach den generativen oder Rapid Prototyping (RP) Verfahren haben sich in diesem Zusammenhang vor allem als Hilfsmittel zur effektiven Kommunikation und zur Evaluierung von Produkteigenschaften einen festen Platz in der Produktentstehung erworben. Die positiven Effekte der etablierten RP Verfahren sind unumstritten. Einfachere, schnellere und wirtschaftlichere Maschinen (Prototyper, Fabrikator), vor allem auch für die Büroumgebung, geben neue Impulse im Sinne der Optimierung der heutigen Verfahren. Eine neue Dimension verspricht die Option „Farbe“ der bisher fast ausschließlich monochromen Modelle. Ist Farbe nur „nice to have“ oder welchen Effekt haben farbige Modelle als Werkzeug von Konstrukteuren und Produktenwicklern? Welche Perspektiven bietet „Farbe“ darüber hinaus?
IT-Sicherheit im Automobil
(2014)
Unsteady flow measurements in the wake behind a wind-tunnel car model by using high-speed planar PIV
(2015)
This study investigates unsteady characteristics of the wake behind a 28%-scale car model in a wind tunnel using highspeed planar particle image velocimetry (PIV). The car model is based on a hatchback passenger car that is known to have relatively high fluctuations in its aerodynamic loads. This study primarily focuses on the lateral motion of the flow on the horizontal plane to determine the effect of the flow motion on the straight-line stability and the initial steering response of the actual car on a track. This paper first compares the flow fields in the wake behind the above mentioned model obtained using conventional and high-speed planar PIV, with sampling frequencies of 8 Hz and 1 kHz, respectively. Large asymmetrically coherent flow structures, which fluctuate at frequencies below 2 Hz, are observed in the results of highspeed PIV measurements, whereas conventional PIV is unable to capture these features of the flow owing to aliasing. This flow pattern with a laterally swaying motion is represented by opposite signs of cross-correlation coefficients of streamwise velocity fluctuations for the two sides of the car model. Effects of two aerodynamic devices that are known to reduce the
fluctuation levels of the aerodynamic loads are then extensively investigated. The correlation analyses reveal that these devices indeed reduce the fluctuation levels of the flow and the correlation values around the rear combination-lamp, but it is found that the effects of these devices are different around the c-pillar.