Refine
Year of publication
Institute
Language
- English (139)
- German (114)
- Multiple languages (1)
Document Type
- Conference Proceeding (129)
- Article (81)
- Part of a Book (27)
- Book (10)
- Report (3)
- Conference: Meeting Abstract (1)
- Diploma Thesis (1)
- Doctoral Thesis (1)
- Talk (1)
Keywords
- Earthquake (5)
- Seismic design (4)
- INODIS (3)
- Out-of-plane load (3)
- Seismic loading (3)
- earthquakes (3)
- Adjacent buildings (2)
- Historical centres (2)
- INSYSME (2)
- Masonry infill (2)
- Shake table test (2)
- Stone masonry (2)
- Tanks (2)
- industrial facilities (2)
- installations (2)
- piping (2)
- seismic design (2)
- seismic loading (2)
- Artificial intelligence (1)
- Ausfachungsmauerwerk (1)
- BIM (1)
- Basisisolierung (1)
- Bauwerksüberwachung (1)
- Behaviour factor q (1)
- Bemessung (1)
- Blind prediction competition (1)
- Capacity Curve (1)
- Cardiovascular MRI (1)
- Civil engineering (1)
- Components (1)
- DIN EN 1996 (1)
- Decoupling (1)
- Design examples (1)
- EN 1998-4 (1)
- ESHM20, industrial facilities (1)
- Earthquake Engineering (1)
- Emilia-Romagna earthquake (1)
- Empirical consequence curves (1)
- Empirical fragility functions (1)
- Erdbeben (1)
- Erdbebeneinwirkung (1)
- Eurocode 8 (1)
- Frame structure (1)
- Genetic algorithm (1)
- Gust wind response (1)
- In- plane damage (1)
- In-plane (1)
- In-plane load (1)
- In-plane performance, isolation (1)
- Industrial facilities (1)
- Industrial units (1)
- Infill wall design (1)
- Interaction (1)
- Isolation (1)
- Left ventriular function (1)
- Linear elastic analysis (1)
- MR-stethoscope (1)
- Magnetic field strength (1)
- Magnetic resonance imaging (MRI) (1)
- Masonry partition walls (1)
- Masonry structures (1)
- Mauerwerksbauten (1)
- Mauerwerksgebäude (1)
- Modern constructions (1)
- Momentenverteilung (1)
- Monitoring (1)
- Monte Carlo Tree Search (1)
- Multi-storey (1)
- Neo-Deterministic (1)
- Numerical modelling (1)
- Out-of-plane (1)
- Out-of-plane capacity (1)
- Out-of-plane failure (1)
- Out-of-plane strength (1)
- PBEE (1)
- Piping (1)
- Precast buildings (1)
- Pushover analysis (1)
- PushoverAnalysen (1)
- RC frames (1)
- Rahmentragwirkung (1)
- Reinforced concrete frame (1)
- Response spectrum (1)
- Seismic (1)
- Seismic Hazard (1)
- Sensor (1)
- Silos (1)
- Slab deflection (1)
- Spectral analysis (1)
- Stahlbetonrahmen (1)
- Structural design (1)
- Structural health monitoring (1)
- Tank (1)
- Unreinforced masonry buildings (1)
- Unreinforced masonry walls (1)
- Verhaltensbeiwerte (1)
- Vulnerability Curves (1)
- Wand-Decken-Interaktion (1)
- Wind turbulence (1)
- Window opening (1)
- Ziegelmauerwerk (1)
- behaviour factor q (1)
- body limbs (1)
- cardiac gating (1)
- cardiovascular MR imaging (1)
- churches (1)
- connection detail (1)
- deserts (1)
- early warning and response system (1)
- earthquake (1)
- earthquake engineering (1)
- elastomeric bearing (1)
- electrocardiogram (1)
- equivalent stiffness (1)
- finite element method (1)
- fluid structure interaction (1)
- fragility curves (1)
- friction pendulum bearing (1)
- granular silo (1)
- high field MR imaging (1)
- hypoplasticity (1)
- impulsive effects (1)
- in-plane (1)
- in-plane and out-of-plane failure (1)
- in-plane behaviour (1)
- integration SHM in BIM (1)
- interconnected sensor systems (1)
- linear elastic analysis; (1)
- liquid storage tank (1)
- liquid-storage tank (1)
- liquid-structure interaction (1)
- lizards (1)
- macro-element (1)
- magnetic resonance imaging (1)
- masonry infill (1)
- masonry structures (1)
- modern constructions (1)
- nonlinear transient analyses (1)
- out-of-plane (1)
- out-of-plane behaviour (1)
- phonocardiogram (1)
- safety control (1)
- seismic (1)
- seismic hazard (1)
- seismic isolation (1)
- seismic response (1)
- seismic risk (1)
- seismic structural damage detection via SHM (1)
- seismic vulnerability (1)
- simplified approach (1)
- structure-soil-structure interaction (1)
- swimming (1)
- truss (1)
- unreinforced masonry buildings (1)
- vault (1)
- vocal fold oscillation (1)
Is part of the Bibliography
- no (254)
Nowadays modern high-performance buildings and facilities are equipped with monitoring systems and sensors to control building characteristics like energy consumption, temperature pattern and structural safety. The visualization and interpretation of sensor data is typically based on simple spreadsheets and non-standardized user-oriented solutions, which makes it difficult for building owners, facility managers and decision-makers to evaluate and understand the data. The solution of this problem in the future are integrated BIM-Sensor approaches which allow the generation of BIM models incorporating all relevant information of monitoring systems. These approaches support both the dynamic visualization of key structural performance parameters, the effective long-term management of sensor data based on BIM and provide a user-friendly interface to communicate with various stakeholders. A major benefit for the end user is the use of the BIM software architecture, which is the future standard anyway. In the following, the application of the integrated BIM-Sensor approach is illustrated for a typical industrial facility as a part of an early warning and rapid response system for earthquake events currently developed in the research project “ROBUST” with financial support by the German Federal Ministry for Economic Affairs and Energy (BMWI).
Armiranobetonske (AB) zgrade sa zidanom ispunom
se izvode u mnogim zemljama širom sveta. Iako se
zidana ispuna posmatra kao nekonstruktivni element, ona
značajno utiče na promenu dinamičkih karakteristika AB
ramovskih konstrukcija u toku zemljotresnog dejstva.
Odskora, značajan napor je utrošen na istraživanje
izolovanih ispuna, koje su odvojene od okolnog rama
obično ostavljanjem prostora između rama i ispune. U
ovom slučaju deformacija rama ne aktivira ispunu i na taj
način ispuna ne utiče na ponašanje rama. Ovaj rad
predstavlja rezultate istraživanja ponašanja AB
ramovskih zgrada sa INODIS sistemom koji izoluje ispunu
u odnosu na okolni ram. Uticaj izolovane ispune je prvo
ispitan na jednospratnim i jednobrodnim ramovima. Ovo
je iskorišćeno kao osnova za parametarsku analizu na
višespratnim i višebrodnim ramovima, kao i na primeru
zgrade. Promena krutosti i dinamičkih karakteristika je
analizirano kao i odgovor pri zemljotresnom dejstvu.
Izvršeno je poređenje sa praznom ramovskom
konstrukcijom kao i ramovima ispunjenim ispunom na
tradicionalni način. Rezultati pokazuju da je ponašanje
ramova sa izolovanom ispunom slično ponašanju praznih
ramova, dok je ponašanje ramova sa tradicionalnom
ispunom daleko drugačije i zahteva kompleksne
numeričke modele. Ovo znači da ukoliko se primeni
adekvatna konstruktivna mera izolacije ispune, proračun
ramovskim zgrada sa zidanom ispunom se može
značajno pojednostaviti.
This paper describes the procedure on the evaluation of the masonry chapter for the next generation of Eurocode 8, the European Standard for earthquake-resistant design. In CEN, TC 250/SC8, working group WG 1 has been established to support the subcommittee on the topic of masonry on both design of new structures (EN1998-1) and assessment of existing structures (EN1998-3). The aim is to elaborate suggestions for amendments which fit the current state of the art in masonry and earthquake-resistant design. Focus will be on modelling, simplified methods, linear-analysis (q-values, overstrength-values), nonlinear procedures, out-of-plane design as well as on clearer definition of limit states. Beside these, topics related to general material properties, reinforced masonry, confined masonry, mixed structures and non-structural infills will be covered too. This paper presents the preliminary work and results up to the submission date.
Erdbebennachweis von Mauerwerksbauten mit realistischen Modellen und erhöhten Verhaltensbeiwerten
(2021)
Die Anwendung des linearen Nachweiskonzepts auf Mauerwerksbauten führt dazu, dass bereits heute Standsicherheitsnachweise für Gebäude mit üblichen Grundrissen in Gebieten mit moderaten Erdbebeneinwirkungen nicht mehr geführt werden können. Diese Problematik wird sich in Deutschland mit der Einführung kontinuierlicher probabilistischer Erdbebenkarten weiter verschärfen. Aufgrund der Erhöhung der seismischen Einwirkungen, die sich vielerorts ergibt, ist es erforderlich, die vorhandenen, bislang nicht berücksichtigten Tragfähigkeitsreserven in nachvollziehbaren Nachweiskonzepten in der Baupraxis verfügbar zu machen. Der vorliegende Beitrag stellt ein Konzept für die gebäudespezifische Ermittlung von erhöhten Verhaltensbeiwerten vor. Die Verhaltensbeiwerte setzen sich aus drei Anteilen zusammen, mit denen die Lastumverteilung im Grundriss, die Verformungsfähigkeit und Energiedissipation sowie die Überfestigkeiten berücksichtigt werden. Für die rechnerische Ermittlung dieser drei Anteile wird ein nichtlineares Nachweiskonzept auf Grundlage von Pushover-Analysen vorgeschlagen, in denen die Interaktionen von Wänden und Geschossdecken durch einen Einspanngrad beschrieben werden. Für die Bestimmung der Einspanngrade wird ein nichtlinearer Modellierungsansatz eingeführt, mit dem die Interaktion von Wänden und Decken abgebildet werden kann. Die Anwendung des Konzepts mit erhöhten gebäudespezifischen Verhaltensbeiwerten wird am Beispiel eines Mehrfamilienhauses aus Kalksandsteinen demonstriert. Die Ergebnisse der linearen Nachweise mit erhöhten Verhaltensbeiwerten für dieses Gebäude liegen deutlich näher an den Ergebnissen nichtlinearer Nachweise und somit bleiben übliche Grundrisse in Erdbebengebieten mit den traditionellen linearen Rechenansätzen nachweisbar.
Influence of slab deflection on the out-of-plane capacity of unreinforced masonry partition walls
(2023)
Severe damage of non-structural elements is noticed in previous earthquakes, causing high economic losses and posing a life threat for the people. Masonry partition walls are one of the most commonly used non-structural elements. Therefore, their behaviour under earthquake loading in out-of-plane (OOP) direction is investigated by several researches in the past years. However, none of the existing experimental campaigns or analytical approaches consider the influence of prior slab deflection on OOP response of partition walls. Moreover, none of the existing construction techniques for the connection of partition walls with surrounding reinforced concrete (RC) is investigated for the combined slab deflection and OOP loading. However, the inevitable time-dependent behaviour of RC slabs leads to high values of final slab deflections which can further influence boundary conditions of partition walls. Therefore, a comprehensive study on the influence of slab deflection on the OOP capacity of masonry partitions is conducted. In the first step, experimental tests are carried out. Results of experimental tests are further used for the calibration of the numerical model employed for a parametric study. Based on the results, behaviour under combined loading for different construction techniques is explained. The results show that slab deflection leads either to severe damage or to a high reduction of OOP capacity. Existing practical solutions do not account for these effects. In this contribution, recommendations to overcome the problems of combined slab deflection and OOP loading on masonry partition walls are given. Possible interaction of in-plane (IP) loading, with the combined slab deflection and OOP loading on partition walls, is not investigated in this study.
Im Rahmen des europäischen Verbundprojekts INSYSME wurden von den deutschen Partnern die Systeme IMES und INODIS zur Verbesserung des seismischen Verhaltens von ausgefachten Stahlbetonrahmen entwickelt. Ziel beider Systeme ist es, Stahlbetonrahmen und Ausfachung zu entkoppeln, anstatt die Tragfähigkeit durch aufwendige und kostspielige zusätzliche Bewehrungseinlagen zu erhöhen. Erste Ergebnisse des Systems IMES für Belastungen in und senkrecht zu der Wandebene werden vorgestellt.
Because of simple construction process, high energy efficiency, significant fire resistance and excellent sound isolation, masonry infilled reinforced concrete (RC) frame structures are very popular in most of the countries in the world, as well as in seismic active areas. However, many RC frame structures with masonry infills were seriously damaged during earthquake events, as the traditional infills are generally constructed with direct contact to the RC frame which brings undesirable infill/frame interaction. This interaction leads to the activation of the equivalent diagonal strut in the infill panel, due to the RC frame deformation, and combined with seismically induced loads perpendicular to the infill panel often causes total collapses of the masonry infills and heavy damages to the RC frames. This fact was the motivation for developing different approaches for improving the behaviour of masonry infills, where infill isolation (decoupling) from the frame has been more intensively studied in the last decade. In-plane isolation of the infill wall reduces infill activation, but causes the need for additional measures to restrain out-of-plane movements. This can be provided by installing steel anchors, as proposed by some researchers. Within the framework of European research project INSYSME (Innovative Systems for Earthquake Resistant Masonry Enclosures in Reinforced Concrete Buildings) the system based on a use of elastomers for in-plane decoupling and steel anchors for out-of-plane restrain was tested. This constructive solution was tested and deeply investigated during the experimental campaign where traditional and decoupled masonry infilled RC frames with anchors were subjected to separate and combined in-plane and out-of-plane loading. Based on a detailed evaluation and comparison of the test results, the performance and effectiveness of the developed system are illustrated.