Refine
Year of publication
Institute
Has Fulltext
- no (246) (remove)
Language
- English (132)
- German (113)
- Multiple languages (1)
Document Type
- Conference Proceeding (121)
- Article (81)
- Part of a Book (27)
- Book (10)
- Report (3)
- Conference: Meeting Abstract (1)
- Diploma Thesis (1)
- Doctoral Thesis (1)
- Talk (1)
Keywords
- Earthquake (5)
- Seismic design (4)
- INODIS (3)
- Out-of-plane load (3)
- Seismic loading (3)
- earthquakes (3)
- Adjacent buildings (2)
- Historical centres (2)
- INSYSME (2)
- Masonry infill (2)
- Shake table test (2)
- Stone masonry (2)
- Tanks (2)
- industrial facilities (2)
- installations (2)
- piping (2)
- seismic design (2)
- seismic loading (2)
- Artificial intelligence (1)
- Ausfachungsmauerwerk (1)
- BIM (1)
- Basisisolierung (1)
- Bauwerksüberwachung (1)
- Behaviour factor q (1)
- Bemessung (1)
- Blind prediction competition (1)
- Capacity Curve (1)
- Cardiovascular MRI (1)
- Civil engineering (1)
- Components (1)
- DIN EN 1996 (1)
- Decoupling (1)
- Design examples (1)
- EN 1998-4 (1)
- ESHM20, industrial facilities (1)
- Earthquake Engineering (1)
- Emilia-Romagna earthquake (1)
- Empirical consequence curves (1)
- Empirical fragility functions (1)
- Erdbeben (1)
- Erdbebeneinwirkung (1)
- Eurocode 8 (1)
- Frame structure (1)
- Genetic algorithm (1)
- Gust wind response (1)
- In- plane damage (1)
- In-plane (1)
- In-plane load (1)
- In-plane performance, isolation (1)
- Industrial facilities (1)
- Industrial units (1)
- Infill wall design (1)
- Interaction (1)
- Isolation (1)
- Left ventriular function (1)
- Linear elastic analysis (1)
- MR-stethoscope (1)
- Magnetic field strength (1)
- Magnetic resonance imaging (MRI) (1)
- Masonry partition walls (1)
- Masonry structures (1)
- Mauerwerksbauten (1)
- Mauerwerksgebäude (1)
- Modern constructions (1)
- Momentenverteilung (1)
- Monitoring (1)
- Monte Carlo Tree Search (1)
- Multi-storey (1)
- Neo-Deterministic (1)
- Numerical modelling (1)
- Out-of-plane (1)
- Out-of-plane capacity (1)
- Out-of-plane failure (1)
- Out-of-plane strength (1)
- PBEE (1)
- Piping (1)
- Precast buildings (1)
- Pushover analysis (1)
- PushoverAnalysen (1)
- RC frames (1)
- Rahmentragwirkung (1)
- Reinforced concrete frame (1)
- Response spectrum (1)
- Seismic (1)
- Seismic Hazard (1)
- Sensor (1)
- Silos (1)
- Slab deflection (1)
- Spectral analysis (1)
- Stahlbetonrahmen (1)
- Structural design (1)
- Structural health monitoring (1)
- Tank (1)
- Unreinforced masonry buildings (1)
- Unreinforced masonry walls (1)
- Verhaltensbeiwerte (1)
- Vulnerability Curves (1)
- Wand-Decken-Interaktion (1)
- Wind turbulence (1)
- Window opening (1)
- Ziegelmauerwerk (1)
- behaviour factor q (1)
- body limbs (1)
- cardiac gating (1)
- cardiovascular MR imaging (1)
- churches (1)
- connection detail (1)
- deserts (1)
- early warning and response system (1)
- earthquake (1)
- earthquake engineering (1)
- elastomeric bearing (1)
- electrocardiogram (1)
- equivalent stiffness (1)
- finite element method (1)
- fluid structure interaction (1)
- fragility curves (1)
- friction pendulum bearing (1)
- granular silo (1)
- high field MR imaging (1)
- hypoplasticity (1)
- impulsive effects (1)
- in-plane (1)
- in-plane and out-of-plane failure (1)
- in-plane behaviour (1)
- integration SHM in BIM (1)
- interconnected sensor systems (1)
- linear elastic analysis; (1)
- liquid storage tank (1)
- liquid-storage tank (1)
- liquid-structure interaction (1)
- lizards (1)
- macro-element (1)
- magnetic resonance imaging (1)
- masonry infill (1)
- masonry structures (1)
- modern constructions (1)
- nonlinear transient analyses (1)
- out-of-plane (1)
- out-of-plane behaviour (1)
- phonocardiogram (1)
- safety control (1)
- seismic (1)
- seismic hazard (1)
- seismic isolation (1)
- seismic response (1)
- seismic risk (1)
- seismic structural damage detection via SHM (1)
- seismic vulnerability (1)
- simplified approach (1)
- structure-soil-structure interaction (1)
- swimming (1)
- truss (1)
- unreinforced masonry buildings (1)
- vault (1)
- vocal fold oscillation (1)
Is part of the Bibliography
- no (246)
Because of its minor environmental impact, electricity generation using wind power is getting remarkable. The further growth of the wind industry depends on technological solutions to the challenges in production and construction of the turbines. Wind turbine tower vibrations, which limit power generation efficiency and cause fatigue problems with high maintenance costs, count as one of the main structural difficulties in the wind energy sector. To mitigate tower vibrations auxiliary measures are necessary. The effectiveness of tuned mass damper is verified by means of a numeric study on a 5 MW onshore reference wind turbine. Hereby, also seismic-induced vibrations and soil–structure interaction are considered. Acquired results show that tuned mass damper can effectively reduce resonant tower vibrations and improve the fatigue life of wind turbines. This chapter is also concerned with tuned liquid column damper and a semiactive application of it. Due to its geometric versatility and low prime costs, tuned liquid column dampers are a good alternative to other damping measures, in particular for slender structures like wind turbines.
Baustatik in Beispielen
(2012)
Textile reinforced concrete. Part I: Process model for collaborative research and development
(2003)
Globale Stabilitätsanalysen zylindrischer, seismisch belasteter Tanks auf numerischer Grundlage
(2015)
New coupled finite-infinite element approach for wave propagation simulation of unbounded soil media
(2014)
Die PIA GmbH prüft seit fast 8 Jahren die Standsicherheit von Behältern für Kleinkläranlagen. Diese bestehen in der Regel aus Kunststoff oder Beton und müssen über ihre gesamte Lebensdauer den Beanspruchungen aus Handhabung, Einbau und Betrieb standhalten. Die Standsicherheit kann nach EN 12566 wahlweise durch einen rechnerischen Nachweis oder durch einen praktischen Nachweis wie die Bruchlastprüfung oder die Prüfung in der Grube erfolgen.
A refined substructure technique in the frequency domain is developed, which permits consideration of the interaction effects among adjacent containers through the supporting deformable soil medium. The tank-liquid systems are represented by means of mechanical models, whereas discrete springs and dashpots stand for the soil beneath the foundations. The proposed model is employed to assess the responses of adjacent circular, cylindrical tanks for harmonic and seismic excitations over wide range of tank proportions and soil conditions. The influence of the number, spatial arrangement of the containers and their distance on the overall system's behavior is addressed. The results indicate that the cross-interaction effects can substantially alter the impulsive components of response of each individual element in a tank farm. The degree of this impact is primarily controlled by the tank proportions and the proximity of the predominant natural frequencies of the shell-liquid-soil systems and the input seismic motion. The group effects should be not a priori disregarded, unless the tanks are founded on shallow soil deposit overlying very stiff material or bedrock.
Möglichkeiten und Grenzen der Anwendbarkeit statisch nichtlinearer Verfahren nach DIN EN 1998-1
(2011)
Bei der Ausarbeitung des nationalen Anwendungsdokumentes zur DIN EN 1998-1 waren die in der ENV-Fassung enthaltenen vereinfachten Regeln im Lichte aktueller Forschungsergebnisse zu überprüfen und zu überarbeiten. Die gleiche Aufgabe stellte sich auch für die Neufassung der DIN 4149. In beiden Fällen sind neben konstruktiven Regeln für die Art und Anordnung der zur Gebäudeaussteifung heranzuziehenden Wände im Grundriss Tabellen enthalten, die unter bestimmten Bedingungen den Entfall eines rechnerischen Nachweises der Tragwände im Erdbebenfall ermöglichen. Dies ist für Schwachbebengebiete, wie sie in Deutschland und anderen Ländern Mitteleuropas anzutreffen sind, sinnvoll, um unnötigen Rechenaufwand sowie Probleme mit der Führbarkeit von Nachweisen so weit wie möglich auszuschalten. Im vorliegenden Beitrag werden die Hintergründe der vereinfachten Regeln diskutiert und die Ergebnisse der Anwendung mit verschiedenen Rechenverfahren verglichen und bewertet.
Am 1. Oktober 2013 ist das auf drei Jahre angelegte EU-Forschungsprojekt INSYSME – Innovative Systeme für erdbebentaugliche Ausfachungswände aus Ziegelmauerwerk in Stahlbetonrahmentragwerken – gestartet. Unter der Koordination der Universität Padua beteiligen sich 16 Partner aus sechs europäischen Ländern (Deutschland, Griechenland, Italien, Portugal, Rumänien, Türkei). Als deutsche Partner nehmen die Arbeitsgemeinschaft Mauerziegel aus Bonn, die Universität Kassel sowie das Ingenieurbüro SDA-engineering GmbH aus Herzogenrath, teil. Ziel der deutschen Partner ist die Entwicklung von innovativen Ausfachungssystemen aus monolithischem wärmedämmenden Ziegelmauerwerk, mit denen nicht nur eine erhöhte Erdbebensicherheit, sondern auch die sichere Erfüllung der steigenden Anforderungen aus Windbeanspruchungen gewährleistet werden können. Die Forschungsergebnisse sollen vom Partner SDA-engineering GmbH in die bereits seit einigen Jahren verfügbare Softwarelösung MINEA [1] integriert werden. Weitere Informationen stehen auf den Websites des Projektes [2] zur Verfügung. Im vorliegenden Beitrag werden nach einer kurzen thematischen Einführung die Ergebnisse von Tastversuchen an senkrecht zur Ebene belasteten Ausfachungswänden aus Planziegelmauerwerk vorgestellt. Im Anschluss wird das geplante Arbeitsprogramm der deutschen Partner im Projekt INSYSME beschrieben.