Refine
Year of publication
Institute
- IfB - Institut für Bioengineering (44) (remove)
Has Fulltext
- no (44) (remove)
Document Type
- Article (44) (remove)
Keywords
- Stiffness (2)
- locomotion (2)
- muscle fascicle behavior (2)
- ultrasound (2)
- ultrasound imaging (2)
- Achilles tendon (1)
- Adaptive control (1)
- Ageing (1)
- AlterG (1)
- Anatomy (1)
- Annulus Fibrosus (1)
- Architectural gear ratio (1)
- Assistive technology (1)
- Automatic control (1)
- Disc Degeneration (1)
- External knee adduction moments (1)
- Handbike (1)
- Human-Computer interaction (1)
- Intervertebral Disc (1)
- Intradiscal Pressure (1)
- Inverse dynamic problem (1)
- Inverse kinematic problem (1)
- Iterative learning control (1)
- Manipulated variables (1)
- Muscle (1)
- Muscle Fascicle (1)
- Muscle Force (1)
- Musculoskeletal model (1)
- Musculoskeletal system (1)
- Nucleus Pulposus (1)
- Paralympic sport (1)
- Physiology (1)
- Rehabilitation Technology and Prosthetics (1)
- Rehabilitation engineering (1)
- Robotic rehabilitation (1)
- Running (1)
- Simulation (1)
- Surgical Navigation and Robotics (1)
- Tendon Rupture (1)
- Tendon properties (1)
- achilles tendon (1)
- agility (1)
- biomechanics (1)
- community dwelling (1)
- connective tissue (1)
- drop jump (1)
- electromyography (1)
- energy absorption (1)
- energy dissipation (1)
- force generation (1)
- gait (1)
- healthy aging (1)
- high-intensity exercise (1)
- hyper-gravity (1)
- hypo-gravity (1)
- intraclass correlation coefficient (1)
- mechanical buffer (1)
- muscle mechanics (1)
- overload (1)
- parabolic flight (1)
- performance testing (1)
- physiology (1)
- prevention (1)
- psychosocial (1)
- rehabilitation (1)
- running (1)
- sEMG (1)
- sarcomere operating length (1)
- series elastic element behavior (1)
- shoulder (1)
- sprint start (1)
- standard error of measurement (1)
- stiffness (1)
- stretch reflex (1)
- stretch-shortening cycle (1)
- tendon rupture (1)
- test-retest reliability (1)
- ultrasonography (1)
- unloading (1)
- walking (1)
- walking gait (1)
Based on the European Space Agency (ESA) Science in Space Environment (SciSpacE) community White Paper “Human Physiology – Musculoskeletal system”, this perspective highlights unmet needs and suggests new avenues for future studies in musculoskeletal research to enable crewed exploration missions. The musculoskeletal system is essential for sustaining physical function and energy metabolism, and the maintenance of health during exploration missions, and consequently mission success, will be tightly linked to musculoskeletal function. Data collection from current space missions from pre-, during-, and post-flight periods would provide important information to understand and ultimately offset musculoskeletal alterations during long-term spaceflight. In addition, understanding the kinetics of the different components of the musculoskeletal system in parallel with a detailed description of the molecular mechanisms driving these alterations appears to be the best approach to address potential musculoskeletal problems that future exploratory-mission crew will face. These research efforts should be accompanied by technical advances in molecular and phenotypic monitoring tools to provide in-flight real-time feedback.
Rehabilitative body weight supported gait training aims at restoring walking function as a key element in activities of daily living. Studies demonstrated reductions in muscle and joint forces, while kinematic gait patterns appear to be preserved with up to 30% weight support. However, the influence of body weight support on muscle architecture, with respect to fascicle and series elastic element behavior is unknown, despite this having potential clinical implications for gait retraining. Eight males (31.9 ± 4.7 years) walked at 75% of the speed at which they typically transition to running, with 0% and 30% body weight support on a lower-body positive pressure treadmill. Gastrocnemius medialis fascicle lengths and pennation angles were measured via ultrasonography. Additionally, joint kinematics were analyzed to determine gastrocnemius medialis muscle–tendon unit lengths, consisting of the muscle's contractile and series elastic elements. Series elastic element length was assessed using a muscle–tendon unit model. Depending on whether data were normally distributed, a paired t-test or Wilcoxon signed rank test was performed to determine if body weight supported walking had any effects on joint kinematics and fascicle–series elastic element behavior. Walking with 30% body weight support had no statistically significant effect on joint kinematics and peak series elastic element length. Furthermore, at the time when peak series elastic element length was achieved, and on average across the entire stance phase, muscle–tendon unit length, fascicle length, pennation angle, and fascicle velocity were unchanged with respect to body weight support. In accordance with unchanged gait kinematics, preservation of fascicle–series elastic element behavior was observed during walking with 30% body weight support, which suggests transferability of gait patterns to subsequent unsupported walking.