Refine
Year of publication
Document Type
- Article (31)
- Conference Proceeding (4)
- Doctoral Thesis (1)
Language
- English (36) (remove)
Keywords
- biopotential electrodes (2)
- Biomechanical simulation (1)
- Cementoblast (1)
- Compression (1)
- EEG (1)
- Forces (1)
- Fracture configuration (1)
- Fracture simulation (1)
- Impedance Spectroscopy (1)
- Mechanotransduction (1)
- Proximal humerus fracture (1)
- Rotator cuff (1)
- Sleep EEG (1)
- Tension (1)
- adipose-derived stromal cells (ASCs) (1)
- aortic perfusion (1)
- cell aerosolization (1)
- cell atomization (1)
- computational fluid dynamics analysis (1)
- correlation (1)
Institute
Purpose
Two semi-empirical models were recently published, both making use of existing literature data, but each taking into account different physical phenomena that trigger hemolysis. In the first model, hemoglobin (Hb) release is described as a permeation procedure across the membrane, assuming a shear stress-dependent process (sublethal model). The second model only accounts for hemoglobin release that is caused by cell membrane breakdown, which occurs when red blood cells (RBC) undergo mechanically induced shearing for a period longer than the threshold time (nonuniform threshold model). In this paper, we introduce a model that considers the hemolysis generated by both these possible phenomena.
Methods
Since hemolysis can possibly be caused by permeation of hemoglobin through the RBC functional membrane as well as by release of hemoglobin from RBC membrane breakdown, our proposed model combines both these models. An experimental setup consisting of a Couette device was utilized for validation of our proposed model.
Results
A comparison is presented between the damage index (DI) predicted by the proposed model vs. the sublethal model vs. the nonthreshold model and experimental datasets. This comparison covers a wide range of shear stress for both human and porcine blood. An appropriate agreement between the measured DI and the DI predicted by the present model was obtained.
Conclusions
The semiempirical hemolysis model introduced in this paper aims for significantly enhanced conformity with experimental data. Two phenomenological outcomes become possible with the proposed approach: an estimation of the average time after which cell membrane breakdown occurs under the applied conditions, and a prediction of the ratio between the phenomena involved in hemolysis.
Production and Characterization of Porous Fibroin Scaffolds for Regenerative Medical Application
(2019)
In this study, we describe the manufacturing and characterization of silk fibroin membranes derived from the silkworm Bombyx mori. To date, the dissolution process used in this study has only been researched to a limited extent, although it entails various potential advantages, such as reduced expenses and the absence of toxic chemicals in comparison to other conventional techniques. Therefore, the aim of this study was to determine the influence of different fibroin concentrations on the process output and resulting membrane properties. Casted membranes were thus characterized with regard to their mechanical, structural and optical assets via tensile testing, SEM, light microscopy and spectrophotometry. Cytotoxicity was evaluated using BrdU, XTT, and LDH assays, followed by live–dead staining. The formic acid (FA) dissolution method was proven to be suitable for the manufacturing of transparent and mechanically stable membranes. The fibroin concentration affects both thickness and transparency of the membranes. The membranes did not exhibit any signs of cytotoxicity. When compared to other current scientific and technical benchmarks, the manufactured membranes displayed promising potential for various biomedical applications. Further research is nevertheless necessary to improve reproducible manufacturing, including a more uniform thickness, less impurity and physiological pH within the membranes.
Conventional EEG devices cannot be used in everyday life and
hence, past decade research has been focused on Ear-EEG for mobile,
at-home monitoring for various applications ranging from
emotion detection to sleep monitoring. As the area available for
electrode contact in the ear is limited, the electrode size and location
play a vital role for an Ear-EEG system. In this investigation, we
present a quantitative study of ear-electrodes with two electrode
sizes at different locations in a wet and dry configuration. Electrode
impedance scales inversely with size and ranges from 450 kΩ to
1.29 MΩ for dry and from 22 kΩ to 42 kΩ for wet contact at 10 Hz.
For any size, the location in the ear canal with the lowest impedance
is ELE (Left Ear Superior), presumably due to increased contact
pressure caused by the outer-ear anatomy. The results can be used
to optimize signal pickup and SNR for specific applications. We
demonstrate this by recording sleep spindles during sleep onset
with high quality (5.27 μVrms).
Thrombogenic complications are a main issue in mechanical circulatory support (MCS). There is no validated in vitro method available to quantitatively assess the thrombogenic performance of pulsatile MCS devices under realistic hemodynamic conditions. The aim of this study is to propose a method to evaluate the thrombogenic potential of new designs without the use of complex in-vivo trials. This study presents a novel in vitro method for reproducible thrombogenicity testing of pulsatile MCS systems using low molecular weight heparinized porcine blood. Blood parameters are continuously measured with full blood thromboelastometry (ROTEM; EXTEM, FIBTEM and a custom-made analysis HEPNATEM). Thrombus formation is optically observed after four hours of testing. The results of three experiments are presented each with two parallel loops. The area of thrombus formation inside the MCS device was reproducible. The implantation of a filter inside the loop catches embolizing thrombi without a measurable increase of platelet activation, allowing conclusions of the place of origin of thrombi inside the device. EXTEM and FIBTEM parameters such as clotting velocity (α) and maximum clot firmness (MCF) show a total decrease by around 6% with a characteristic kink after 180 minutes. HEPNATEM α and MCF rise within the first 180 minutes indicate a continuously increasing activation level of coagulation. After 180 minutes, the consumption of clotting factors prevails, resulting in a decrease of α and MCF. With the designed mock loop and the presented protocol we are able to identify thrombogenic hot spots inside a pulsatile pump and characterize their thrombogenic potential.