Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (605) (remove)
Document Type
- Article (532)
- Conference Proceeding (56)
- Part of a Book (10)
- Book (2)
- Other (2)
- Report (2)
- Patent (1)
Keywords
- Biosensor (7)
- LAPS (4)
- hydrogen peroxide (4)
- Field-effect sensor (3)
- Label-free detection (3)
- Light-addressable potentiometric sensor (3)
- biosensors (3)
- Bacillus atrophaeus (2)
- Capacitive field-effect sensor (2)
- Raman spectroscopy (2)
- Tobacco mosaic virus (TMV) (2)
- acetoin (2)
- capacitive field-effect sensors (2)
- field-effect sensor (2)
- impedance spectroscopy (2)
- sterilisation (2)
- tobacco mosaic virus (TMV) (2)
- (Bio)degradation (1)
- Bacillus atrophaeus spores (1)
- Bio-Sensors (1)
- Bioabsorbable (1)
- Biomolecular logic gate (1)
- Biophoton (1)
- Biosensorik (1)
- CNOT (1)
- Calorimetric gas sensor (1)
- Capacitive field-effect (1)
- Capacitive model (1)
- Chemical images (1)
- Chemical imaging (1)
- Chemical imaging sensor (1)
- Chemical sensor (1)
- Coat protein (1)
- C–V method (1)
- DNA (1)
- DNA biosensor (1)
- DNA hybridization (1)
- DPA (dipicolinic acid) (1)
- Dehydrogenase (1)
- Diaphorase (1)
- E. coli detection (1)
- EIS capacitive sensor (1)
- Electrolyte–insulator–semiconductor (1)
- Enzymatic biosensor (1)
- Enzyme biosensor (1)
- Enzyme coverage (1)
- Enzyme logic gate (1)
- Enzyme nanocarrier (1)
- Field effect (1)
- Field-effect biosensor (1)
- Field-effect device (1)
- Gas sensor (1)
- Glucose biosensor (1)
- Glucose oxidase (1)
- Gold nanoparticle (1)
- Gold nanoparticles (1)
- Heavy metal detection (1)
- Hydrogen peroxide (1)
- I3S 2005 (1)
- ISFET (1)
- Impedance spectroscopy (1)
- International Symposium on Sensor Science (1)
- Layer-by-layer adsorption (1)
- LbL films (1)
- Light-addressable Potentiometric Sensor (1)
- MEMS (1)
- MOS (1)
- Master stamp (1)
- Multianalyte detection (1)
- Multicell (1)
- Multiplexing (1)
- Nano Materials (1)
- Nanomaterial (1)
- Nanopartikel (1)
- Nanostructuring (1)
- Nanotechnologie (1)
- Nanotechnology ; Microelectronics ; Biosensors ; Superconductor ; MEMS (1)
- Negative impedance convertor (1)
- O2 plasma (1)
- Organic light-emitting diode display (1)
- Penicillin (1)
- Photolithographic mimics (1)
- Plant virus (1)
- Poly(allylamine hydrochloride) (1)
- Poly(d,l-lacticacid) (1)
- Polyimide (1)
- Polylactide acid (1)
- Potentiometry (1)
- Quartz crystal microbalance (1)
- Real-time monitoring (1)
- Resistive temperature detector (1)
- Resonance-mode measurement (1)
- Silk fibroin (1)
- Simultaneous determination (1)
- Sn₃O₄ (1)
- Sterilisation process (1)
- Supraleiter (1)
- Surface imprinted polymer (1)
- TMV adsorption (1)
- Ta₂O₅ gate (1)
- Tobacco mosaic virus (1)
- Wafer (1)
- XOR (1)
- Zeta potential (1)
- acetoin reductase (1)
- alcoholic beverages (1)
- amperometric biosensors (1)
- annealing (1)
- aquaculture (1)
- artificial olfactory image (1)
- atomic layer deposition (1)
- barium strontium titanate (1)
- bioburdens (1)
- biocompatible (1)
- biocompatible materials (1)
- biodegradabl (1)
- biodegradable electronic devices (1)
- biosensor (1)
- calorimetric gas sensor (1)
- calorimetric gas sensor;hydrogen peroxide;wireless sensor system (1)
- capacitive electrolyte–insulator–semiconductor sensors (1)
- capacitive field-effect biosensor (1)
- capacitive field-effect sensor (1)
- capillary micro-droplet cell (1)
- carbon electrodes (1)
- catalytic decomposition (1)
- catalytic metal (1)
- chemical sensor (1)
- chip-based sensor setup (1)
- contactless conductivity sensor (1)
- electrical conductivity of liquids (1)
- electrolyte-insulator semiconductor sensor (EIS) (1)
- electronic nose (1)
- encapsulation materials (1)
- endospores (1)
- enzymatic (bio)degradation (1)
- enzymatic biosensor (1)
- enzyme cascade (1)
- enzyme immobilization (1)
- fibroin (1)
- field-effect structure (1)
- gas sensor (1)
- glucose (1)
- glucose oxidase (GOx) (1)
- graphene oxide (1)
- heavy metals (1)
- high-k material (1)
- horseradish peroxidase (HRP) (1)
- hydroxylation (1)
- immobilization (1)
- in-situ monitoring (1)
- lable-free detection (1)
- layer expansion (1)
- layer-by-layer technique (1)
- light-addressable potentiometric sensor (1)
- light-addressing technologies (1)
- metal-oxide-semiconductor structure (1)
- microfluidics (1)
- multi-functional material (1)
- nanobelts (1)
- nanomaterials (1)
- novel photoexcitation method (1)
- optical sensor setup (1)
- optical spore trapping (1)
- optical trapping (1)
- organic PVC membranes (1)
- organosilanes (1)
- pH sensors (1)
- pattern-size reduction (1)
- penicillin (1)
- penicillinase (1)
- photoelectrochemistry (1)
- plant virus detection (1)
- plug-based microfluidic device (1)
- poly(d, l-lactic acid) (1)
- polyaniline (1)
- scanned light pulse technique (1)
- self-aligned patterning (1)
- silanization (1)
- spatial resolution (1)
- sterility tests (1)
- sterilization (1)
- sterilization conditions (1)
- sterilization efficacy (1)
- sterilization methods (1)
- surface functionalization (1)
- temperature (1)
- thermometry (1)
- thin-film microsensors (1)
- tilted constant illumination (1)
- titanium dioxide photoanode (1)
- turnip vein clearing virus (TVCV) (1)
- ultrathin gate insulators (1)
- validation methods (1)
- visualization (1)
- wafer-level testing (1)
Visualization of the recovery process of defects in a cultured cell layer by chemical imaging sensor
(2016)
The chemical imaging sensor is a field-effect sensor which is able to visualize both the distribution of ions (in LAPS mode) and the distribution of impedance (in SPIM mode) in the sample. In this study, a novel cell assay is proposed, in which the chemical imaging sensor operated in SPIM mode is applied to monitor the recovery of defects in a cell layer brought into proximity of the sensing surface. A reduced impedance at a defect formed artificially in a cell layer was successfully visualized in a photocurrent image. The cell layer was cultured over two weeks, during which the temporal change of the photocurrent distribution corresponding to the recovery of the defect was observed.
The chemical imaging sensor is a field-effect sensor which is able to visualize both the distribution of ions (in LAPS mode) and the distribution of impedance (in SPIM mode) inthe sample. In this study, a novel wound-healing assay is proposed, in which the chemical imaging sensor operated in SPIM mode is applied to monitor the defect of a cell layer brought into proximity of the sensing surface.A reduced impedance inside the defect, which was artificially formed ina cell layer, was successfully visualized in a photocurrent image.
Using a cell-based gas biosensor for investigation of adverse effects of acetone vapors in vitro
(2013)
In this work, the bioabsorbable materials, namely fibroin, polylactide acid (PLA), magnesium and magnesium oxide are investigated for their application as transient, resistive temperature detectors (RTD). For this purpose, a thin-film magnesium-based meander-like electrode is deposited onto a flexible, bioabsorbable substrate (fibroin or PLA) and encapsulated (passivated) by additional magnesium oxide layers on top and below the magnesium-based electrode. The morphology of different layered RTDs is analyzed by scanning electron microscopy. The sensor performance and lifetime of the RTD is characterized both under ambient atmospheric conditions between 30°C and 43°C, and wet tissue-like conditions with a constant temperature regime of 37°C. The latter triggers the degradation process of the magnesium-based layers. The 3-layers RTDs on a PLA substrate could achieve a lifetime of 8.5 h. These sensors also show the best sensor performance under ambient atmospheric conditions with a mean sensitivity of 0.48 Ω/°C ± 0.01 Ω/°C.
Trace metal determination by dc resistance changes of microstructured thin gold film electrodes
(1999)
An amperometric biosensor using a substrate recycling principle was realized for the detection of low adrenaline concentrations (1 nM) by measurements in phosphate buffer and Ringer’s solution at pH 6.5 and pH 7.4, respectively. In proof-of-concept experiments, a Boolean logic-gate principle has been applied to develop a digital adrenaline biosensor based on an enzyme AND logic gate. The obtained results demonstrate that the developed digital biosensor is capable for a rapid qualitative determination of the presence/absence of adrenaline in a YES/NO statement. Such digital biosensor could be used in clinical diagnostics for the control of a correct insertion of a catheter in the adrenal veins during adrenal venous-sampling procedure.
The LAPS (light-addressable potentiometric sensor) platform is one of the most attractive approaches for chemical and biological sensing with many applications ranging from pH and ion/analyte concentration measurements up to cell metabolism detection and chemical imaging. However, although it is generally accepted that LAPS measurements are spatially resolved, the light-addressability feature of LAPS devices has not been discussed in detail so far. In this work, an extended electrical equivalent-circuit model of the LAPS has been presented, which takes into account possible cross-talk effects due to the capacitive coupling of the non-illuminated region. A shunting effect of the non-illuminated area on the measured photocurrent and addressability of LAPS devices has been studied. It has been shown, that the measured photocurrent will be determined not only by the local interfacial potential in the illuminated region but also by possible interfacial potential changes in the non-illuminated region, yielding cross-talk effects. These findings were supported by the experimental investigations of a penicillin-sensitive multi-spot LAPS and a metal-insulator-semiconductor LAPS as model systems.
A wireless sensor system based on the industrial ZigBee standard for low-rate wireless networking was developed that enables real-time monitoring of gaseous H2O2 during the package sterilization in aseptic food processes. The sensor system consists of a remote unit connected to a calorimetric gas sensor, which was already established in former works, and an external base unit connected to a laptop computer. The remote unit was built up by an XBee radio frequency (RF) module for data communication and a programmable system-on-chip controller to read out the sensor signal and process the sensor data, whereas the base unit is a second XBee RF module. For the rapid H2O2 detection on various locations inside the package that has to be sterilized, a novel read-out strategy of the calorimetric gas sensor was established, wherein the sensor response is measured within the short sterilization time and correlated with the present H2O2 concentration. In an exemplary measurement application in an aseptic filling machinery, the suitability of the new, wireless sensor system was demonstrated, wherein the influence of the gas velocity on the H2O2 distribution inside a package was determined and verified with microbiological tests.
Sterilisation processes are compulsory in medicine, pharmacy, and food industries to prevent infections of consumers and microbiological contaminations of products. Monitoring the sterilisation by conventional microbiological methods is time- and lab-consuming. To overcome this problem, in this work a novel biosensor has been proposed. The sensor enables a fast method to evaluate sterilisation processes. By means of thin-film technology the sensor's transducer structures in form of IDEs (interdigitated electrodes) have been fabricated on a silicon substrate. Physical characterisation of the developed sensor was done by AFM, SEM, and profilometry. Impedance analyses were conducted for the electrical characterisation. As microbiological layer spores of B. atrophaeus have been immobilised on the sensing structure; spores of this type are a well-known sterilisation test organism. Impedance measurements at a fixed frequency over time were performed to monitor the immobilisation process. A sterilisation process according to aseptic filling machines was applied to demonstrate the sensor functionality. After both, immobilisation and sterilisation, a change in impedance could successfully be detected.
Monitoring of organic acids (OA) and volatile fatty acids (VFA) is crucial for the control of anaerobic digestion. In case of unstable process conditions, an accumulation of these intermediates occurs. In the present work, two different enzyme-based biosensor arrays are combined and presented for facile electrochemical determination of several process-relevant analytes. Each biosensor utilizes a platinum sensor chip (14 × 14 mm²) with five individual working electrodes. The OA biosensor enables simultaneous measurement of ethanol, formate, d- and l-lactate, based on a bi-enzymatic detection principle. The second VFA biosensor provides an amperometric platform for quantification of acetate and propionate, mediated by oxidation of hydrogen peroxide. The cross-sensitivity of both biosensors toward potential interferents, typically present in fermentation samples, was investigated. The potential for practical application in complex media was successfully demonstrated in spiked sludge samples collected from three different biogas plants. Thereby, the results obtained by both of the biosensors were in good agreement to the applied reference measurements by photometry and gas chromatography, respectively. The proposed hybrid biosensor system was also used for long-term monitoring of a lab-scale biogas reactor (0.01 m³) for a period of 2 months. In combination with typically monitored parameters, such as gas quality, pH and FOS/TAC (volatile organic acids/total anorganic carbonate), the amperometric measurements of OA and VFA concentration could enhance the understanding of ongoing fermentation processes.
The conjunction of (bio-)chemical recognition elements with nanoscale biological building blocks such as virus particles is considered as a very promising strategy for the creation of biohybrids opening novel opportunities for label-free biosensing. This work presents a new approach for the development of biosensors using tobacco mosaic virus (TMV) nanotubes or coat proteins (CPs) as enzyme nanocarriers. Sensor chips combining an array of Pt electrodes loaded with glucose oxidase (GOD)-modified TMV nanotubes or CP aggregates were used for amperometric detection of glucose as a model system for the first time. The presence of TMV nanotubes or CPs on the sensor surface allows binding of a high amount of precisely positioned enzymes without substantial loss of their activity, and may also ensure accessibility of their active centers for analyte molecules. Specific and efficient immobilization of streptavidin-conjugated GOD ([SA]-GOD) complexes on biotinylated TMV nanotubes or CPs was achieved via bioaffinity binding. These layouts were tested in parallel with glucose sensors with adsorptively immobilized [SA]-GOD, as well as [SA]-GOD crosslinked with glutardialdehyde, and came out to exhibit superior sensor performance. The achieved results underline a great potential of an integration of virus/biomolecule hybrids with electronic transducers for future applications in biosensorics and biochips.
Nanotubular tobacco mosaic virus (TMV) particles and RNA-free lower-order coat protein (CP) aggregates have been employed as enzyme carriers in different diagnostic layouts and compared for their influence on biosensor performance. In the following, we describe a label-free electrochemical biosensor for improved glucose detection by use of TMV adapters and the enzyme glucose oxidase (GOD). A specific and efficient immobilization of streptavidin-conjugated GOD ([SA]-GOD) complexes on biotinylated TMV nanotubes or CP aggregates was achieved via bioaffinity binding. Glucose sensors with adsorptively immobilized [SA]-GOD, and with [SA]-GOD cross-linked with glutardialdehyde, respectively, were tested in parallel on the same sensor chip. Comparison of these sensors revealed that TMV adapters enhanced the amperometric glucose detection remarkably, conveying highest sensitivity, an extended linear detection range and fastest response times. These results underline a great potential of an integration of virus/biomolecule hybrids with electronic transducers for applications in biosensorics and biochips. Here, we describe the fabrication and use of amperometric sensor chips combining an array of circular Pt electrodes, their loading with GOD-modified TMV nanotubes (and other GOD immobilization methods), and the subsequent investigations of the sensor performance.
Thin film chemical sensors based on chalcogenide glasses for „electronic tongue“ applications
(2001)
This study addresses a proof-of-concept experiment with a biocompatible screen-printed carbon electrode deposited onto a biocompatible and biodegradable substrate, which is made of fibroin, a protein derived from silk of the Bombyx mori silkworm. To demonstrate the sensor performance, the carbon electrode is functionalized as a glucose biosensor with the enzyme glucose oxidase and encapsulated with a silicone rubber to ensure biocompatibility of the contact wires. The carbon electrode is fabricated by means of thick-film technology including a curing step to solidify the carbon paste. The influence of the curing temperature and curing time on the electrode morphology is analyzed via scanning electron microscopy. The electrochemical characterization of the glucose biosensor is performed by amperometric/voltammetric measurements of different glucose concentrations in phosphate buffer. Herein, systematic studies at applied potentials from 500 to 1200 mV to the carbon working electrode (vs the Ag/AgCl reference electrode) allow to determine the optimal working potential. Additionally, the influence of the curing parameters on the glucose sensitivity is examined over a time period of up to 361 days. The sensor shows a negligible cross-sensitivity toward ascorbic acid, noradrenaline, and adrenaline. The developed biocompatible biosensor is highly promising for future in vivo and epidermal applications.
In this article, we present an overview on the thermocatalytic reaction of hydrogen peroxide (H₂O₂) gas on a manganese (IV) oxide (MnO₂) catalytic structure. The principle of operation and manufacturing techniques are introduced for a calorimetric H₂O₂ gas sensor based on porous MnO₂. Results from surface analyses by X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM) of the catalytic material provide indication of the H₂O₂ dissociation reaction schemes. The correlation between theory and the experiments is documented in numerical models of the catalytic reaction. The aim of the numerical models is to provide further information on the reaction kinetics and performance enhancement of the porous MnO₂ catalyst.