Refine
Year of publication
Document Type
- Article (13)
- Conference Proceeding (9)
- Part of a Book (3)
- Doctoral Thesis (1)
Keywords
- Finite-Elemente-Methode (5)
- Limit analysis (4)
- Shakedown analysis (3)
- damage (2)
- Anastomose (1)
- Anastomosis (1)
- Anastomotic leakage (1)
- Autolysis (1)
- Biomechanics (1)
- Biomechanik (1)
- Decomposition (1)
- End-to-end colorectal anastomosis (1)
- Exact Ilyushin yield surface (1)
- Finite element method (1)
- Finite element modelling (1)
- First Order Reliabiblity Method (1)
- First-order reliability method (1)
- Freeze–thaw process (1)
- Liver (1)
- Multimode failure (1)
Institute
- IfB - Institut für Bioengineering (26) (remove)
Load bearing capacity of thin shell structures made of elastoplastic material by direct methods
(2008)
Shakedown analysis of two dimensional structures by an edge-based smoothed finite element method
(2010)
Summary: This paper presents a methodology to study and understand the mechanics of stapled anastomotic behaviors by combining empirical experimentation and finite element analysis. Performance of stapled anastomosis is studied in terms of leakage and numerical results which are compared to in vitro experiments performed on fresh porcine tissue. Results suggest that leaks occur between the tissue and staple legs penetrating through the tissue.
This paper presents a novel numerical procedure for computing limit and shakedown loads of structures using a node-based smoothed FEM in combination with a primal–dual algorithm. An associated primal–dual form based on the von Mises yield criterion is adopted. The primal-dual algorithm together with a Newton-like iteration are then used to solve this associated primal–dual form to determine simultaneously both approximate upper and quasi-lower bounds of the plastic collapse limit and the shakedown limit. The present formulation uses only linear approximations and its implementation into finite element programs is quite simple. Several numerical examples are given to show the reliability, accuracy, and generality of the present formulation compared with other available methods.
The impact of surgical staplers on tissues has been studied mostly in an empirical manner. In this paper, finite element method was used to clarify the mechanics of tissue stapling and associated phenomena. Various stapling modalities and several designs of circular staplers were investigated to evaluate the impact of the device on tissues and mechanical performance of the end-to-end colorectal anastomosis. Numerical simulations demonstrated that a single row of staples is not adequate to resist leakage due to non-linear buckling and opening of the tissue layers between two adjacent staples. Compared to the single staple row configuration, significant increase in stress experienced by the tissue at the inner staple rows was observed in two and three rows designs. On the other hand, adding second and/or third staple row had no effect on strain in the tissue inside the staples. Variable height design with higher staples in outer rows significantly reduced the stresses and strains in outer rows when compared to the same configuration with flat cartridge.