Fachbereich Energietechnik
Refine
Year of publication
Institute
- Fachbereich Energietechnik (588)
- Solar-Institut Jülich (33)
- INB - Institut für Nano- und Biotechnologien (26)
- Nowum-Energy (21)
- ECSM European Center for Sustainable Mobility (15)
- Kommission für Forschung und Entwicklung (14)
- Fachbereich Chemie und Biotechnologie (6)
- Fachbereich Medizintechnik und Technomathematik (5)
- Fachbereich Bauingenieurwesen (4)
- Arbeitsstelle fuer Hochschuldidaktik und Studienberatung (1)
Language
- English (588) (remove)
Document Type
- Article (361)
- Conference Proceeding (177)
- Part of a Book (25)
- Book (8)
- Conference: Meeting Abstract (7)
- Talk (3)
- Doctoral Thesis (2)
- Other (2)
- Conference Poster (1)
- Master's Thesis (1)
Keywords
- Blitzschutz (6)
- Earthquake (5)
- Diversity Management (4)
- Energy storage (4)
- Power plants (4)
- Seismic design (4)
- Associated liquids (3)
- Concentrated solar power (3)
- Elektromagnetischer Schutzschild (3)
- Hybrid energy system (3)
- Lightning (3)
- Out-of-plane load (3)
- Seismic loading (3)
- earthquakes (3)
- Adjacent buildings (2)
- Central receiver power plant (2)
- Concentrated systems (2)
- Direkter Blitzschlag (2)
- Diversity (2)
- Electricity generation (2)
- Engineering Habitus (2)
- Erneuerbare Energien (2)
- Gas turbine (2)
- Historical centres (2)
- Human-robot collaboration (2)
- Hybridsystem (2)
- INODIS (2)
- Induzierte Spannungen (2)
- Innovation Management (2)
- Lightning protection (2)
- Lightning protection system (2)
- Magnetische Felder (2)
- Masonry infill (2)
- Organizational Culture (2)
- Renewable energy (2)
- Risikoabwägung (2)
- Shake table test (2)
- Solar thermal technologies (2)
- Stone masonry (2)
- Tanks (2)
- cyber physical production system (2)
- digital shadow (2)
- electromagnetic shielding (2)
- engineering education (2)
- industrial facilities (2)
- installations (2)
- piping (2)
- reinforced concrete (2)
- seismic design (2)
- seismic loading (2)
- Academia (1)
- Acceptance (1)
- Algal Turf Scrubber (1)
- Algal–bacterial bioflm (1)
- Anti-Bias (1)
- Antibias (1)
- Artificial intelligence (1)
- Behaviour factor q (1)
- Best practice sharing (1)
- Biogas (1)
- Blind prediction competition (1)
- Blitz (1)
- Blitzrisiko (1)
- Blitzschlag (1)
- Bloom Taxonomy (1)
- COMSOL Multiphysics (1)
- Camera system (1)
- Capacity Curve (1)
- Cardiovascular MRI (1)
- Central receiver system (1)
- Ceramics (1)
- Change Management (1)
- Change management (1)
- Circular bioeconomy (1)
- Civil engineering (1)
- Cloud passages (1)
- Cognitive assistance system (1)
- Components (1)
- Concentrated solar collector (1)
- Concentrating solar power (1)
- Control optimization (1)
- Corporate Culture (1)
- DAC (1)
- DNI forecast (1)
- DNI forecasting (1)
- Decision theory (1)
- Decoupling (1)
- Design Thinking (1)
- Design examples (1)
- Digital leadership (1)
- Digitalization (1)
- Direct lightning strike (1)
- Direct normal irradiance forecast (1)
- District data model (1)
- District energy planning platform (1)
- Diversity management (1)
- Dynamic simulation (1)
- EN 1998-4 (1)
- ESHM20, industrial facilities (1)
- Earthquake Engineering (1)
- Electrochemistry (1)
- Elektromagnetische Kopplung (1)
- Emilia-Romagna earthquake (1)
- Empirical consequence curves (1)
- Empirical fragility functions (1)
- Energietechnik (1)
- Energy (1)
- Energy Systems (1)
- Energy system (1)
- Energy system planning (1)
- Engineering (1)
- Engineering Education (1)
- Ethics (1)
- Eurocode 8 (1)
- Fracture classification (1)
- Frame structure (1)
- Fresnel power plant (1)
- Future Skills (1)
- Future skills (1)
- Gasturbine (1)
- Gender (1)
- Genetic algorithm (1)
- Germany (1)
- Global change (1)
- Gust wind response (1)
- Heliostat Field Calibration (1)
- Heliostats (1)
- Higher Education (1)
- Hilbert Room (1)
- Human factors (1)
- Human-centered work design (1)
- Hybridization (1)
- INSYSME (1)
- Imaging (1)
- In- plane damage (1)
- In-plane (1)
- In-plane load (1)
- In-plane performance, isolation (1)
- Inclusive work climate (1)
- Industrial facilities (1)
- Industrial units (1)
- Industrieanlagen (1)
- Infill wall design (1)
- Innovation (1)
- Interaction (1)
- Interculturality (1)
- Interdisciplinarity (1)
- Isolation (1)
- Kalkulation (1)
- Kernenergie (1)
- Key competences (1)
- Kraftwerke (1)
- Leadership (1)
- Left ventriular function (1)
- Lightning Protection (1)
- Lightning Risk (1)
- Linear elastic analysis (1)
- LiveLink for MATLAB (1)
- MR-stethoscope (1)
- Magnetic field strength (1)
- Magnetic resonance imaging (MRI) (1)
- Masonry partition walls (1)
- Masonry structures (1)
- Maßstabsgetreues Modell (1)
- Measuring instruments (1)
- Methane (1)
- Micro turbine (1)
- Mikrogasturbine (1)
- Mixed integer linear programming (MILP) (1)
- Modern constructions (1)
- Molten salt receiver (1)
- Molten salt receiver system (1)
- Molten salt receiver system, (1)
- Molten salt solar tower (1)
- Monte Carlo Tree Search (1)
- Morphing (1)
- Multi-storey (1)
- Neo-Deterministic (1)
- Nowcasting (1)
- Nuclear Applications (1)
- Numerical modelling (1)
- Operators (1)
- Optimization module (1)
- Organizational culture (1)
- Out-of-plane (1)
- Out-of-plane capacity (1)
- Out-of-plane failure (1)
- Out-of-plane strength (1)
- PBEE (1)
- PTC (1)
- Parabolic trough collector (1)
- Perception (1)
- Photovoltaics (1)
- Photovoltaikanlage (1)
- Piping (1)
- Postulates (1)
- Power conversion systems (1)
- Precast buildings (1)
- Privacy (1)
- Probability distribution mapping (1)
- Process prediction (1)
- Psychological concepts (1)
- Pushover analysis (1)
- Pyrometrie (1)
- Quadrocopter (1)
- Quantenmechanik (1)
- RC frames (1)
- Reinforced concrete frame (1)
- Renewable energy integration (1)
- Response spectrum (1)
- Responsibility (1)
- Risiko (1)
- Risk (1)
- Risk Assessment (1)
- Risk Management (1)
- Schrödingers cat (1)
- Seismic (1)
- Seismic Hazard (1)
- Shoulder (1)
- Silos (1)
- Slab deflection (1)
- Social impact measurement (1)
- Solar concentration (1)
- Solar dish (1)
- Solar irradiance (1)
- Spectral analysis (1)
- Stahlbeton (1)
- Stahlbetonkonstruktion (1)
- Star design (1)
- Structural design (1)
- Structural health monitoring (1)
- Sustainability (1)
- Sustainable engineering education (1)
- Tank (1)
- Temperaturmessung (1)
- Thermal Energy Storage (1)
- Time-series aggregation (1)
- Transient flux distribution (1)
- Two-phase modelling (1)
- Typical periods (1)
- UAV (1)
- Umwelt (1)
- Uncertainty analysis (1)
- Unmanned aerial vehicle (1)
- Unreinforced masonry buildings (1)
- Unreinforced masonry walls (1)
- Vulnerability Curves (1)
- Wind turbulence (1)
- Windenergieanlage (1)
- Window opening (1)
- acoustic pyrometry (1)
- behaviour factor q (1)
- best practice (1)
- bio-methane (1)
- body limbs (1)
- bubble column (1)
- bullying (1)
- calculations (1)
- carbon dioxide removal (1)
- cardiac gating (1)
- cardiovascular MR imaging (1)
- change management (1)
- churches (1)
- climate neutrality (1)
- concentrating collector (1)
- connection detail (1)
- current distribution (1)
- cyber-physical production system (1)
- deserts (1)
- digital twin (1)
- digitalization (1)
- direct air capture (1)
- dissemination (1)
- distribution grid simulation (1)
- diversity (1)
- diversity management (1)
- down-conductor (1)
- e-mobility (1)
- early warning and response system (1)
- earthquake (1)
- earthquake engineering (1)
- economics (1)
- education (1)
- elastomeric bearing (1)
- electrocardiogram (1)
- electromagnetic coupling (1)
- electromagnetic shield (1)
- energy transition (1)
- engineering (1)
- environment (1)
- equivalent stiffness (1)
- finite element method (1)
- flue gas components (1)
- fluid structure interaction (1)
- fragility curves (1)
- friction pendulum bearing (1)
- gender and diversity (1)
- granular silo (1)
- high field MR imaging (1)
- human digital shadow (1)
- human factors (1)
- human-machine interface (1)
- hybrid system (1)
- hybrid-system (1)
- hypoplasticity (1)
- impulsive effects (1)
- in-plane (1)
- in-plane and out-of-plane failure (1)
- induced voltage (1)
- induced voltages (1)
- innovation (1)
- innovation management (1)
- integration SHM in BIM (1)
- interconnected sensor systems (1)
- internet of production (1)
- lessons learned (1)
- lightning flash (1)
- linear elastic analysis; (1)
- liquid storage tank (1)
- liquid-storage tank (1)
- liquid-structure interaction (1)
- lizards (1)
- macro-element (1)
- magnetic field (1)
- magnetic fields (1)
- magnetic resonance imaging (1)
- masonry structures (1)
- metal façade (1)
- methanation (1)
- modern constructions (1)
- negative emissions (1)
- nonlinear transient analyses (1)
- open educational resources (1)
- out-of-plane (1)
- overvoltages (1)
- phonocardiogram (1)
- photovoltaic system (1)
- plug flow reactor (1)
- point-focussing system (1)
- policy recommendations (1)
- power-to-gas (1)
- protection measures (1)
- raytracing (1)
- recommendations for actions (1)
- renewable energies (1)
- renewable energy (1)
- research association (1)
- risk assessment (1)
- rollout (1)
- safety control (1)
- scaled model (1)
- seismic hazard (1)
- seismic isolation (1)
- seismic response (1)
- seismic risk (1)
- seismic structural damage detection via SHM (1)
- seismic vulnerability (1)
- simplified approach (1)
- smart-charging (1)
- social responsible engineering (1)
- solar process heat (1)
- steam production (1)
- steel columns (1)
- storage dispatch (1)
- storage optimisation (1)
- structure-soil-structure interaction (1)
- swimming (1)
- teaching (1)
- temperature measurement (1)
- thermal storage (1)
- touch voltage (1)
- truss (1)
- unreinforced masonry buildings (1)
- user & usage (1)
- vault (1)
- vocal fold oscillation (1)
- wind turbine (1)
- Überspannung (1)
Simulation and measurement of melting effects on metal sheets caused by direct lightning strikes
(1991)
Simulating the electromagnetic‐thermal treatment of thin aluminium layers for adhesion improvement
(2015)
A composite layer material used in packaging industry is made from joining layers of different materials using an adhesive. An important processing step in the production of aluminium-containing composites is the surface treatment and consequent coating of adhesive material on the aluminium surface. To increase adhesion strength between aluminium layer and the adhesive material, the foil is heat treated. For efficient heating, induction heating was considered as state-of-the-art treatment process. Due to the complexity of the heating process and the unpredictable nature of the heating source, the control of the process is not yet optimised. In this work, a finite element analysis of the process was established and various process parameters were studied. The process was simplified and modelled in 3D. The numerical model contains an air domain, an aluminium layer and a copper coil fitted with a magnetic field concentrating material. The effect of changing the speed of the aluminium foil (or rolling speed) was studied with the change of the coil current. Statistical analysis was used for generating a general control equation of coil current with changing rolling speed.
Shielding effectiveness of reinforced concrete cable ducts carrying partial lightning currents
(1998)
SHEMAT-Suite: An open-source code for simulating flow, heat and species transport in porous media
(2020)
SHEMAT-Suite is a finite-difference open-source code for simulating coupled flow, heat and species transport in porous media. The code, written in Fortran-95, originates from geoscientific research in the fields of geothermics and hydrogeology. It comprises: (1) a versatile handling of input and output, (2) a modular framework for subsurface parameter modeling, (3) a multi-level OpenMP parallelization, (4) parameter estimation and data assimilation by stochastic approaches (Monte Carlo, Ensemble Kalman filter) and by deterministic Bayesian approaches based on automatic differentiation for calculating exact (truncation error-free) derivatives of the forward code.
Semi-insulating GaAs layers grown by molecular-beam epitaxy / P. Kordos ; A. Förster ; J. Betko ...
(1995)
A methodology for assessment, seismic verification and strengthening of existing masonry buildings is presented in this paper. The verification is performed using a calculation model calibrated with the results from ambient vibration measurements. The calibrated model serves as an input for a deformation-based verification procedure based on the Capacity Spectrum Method (CSM). The bearing capacity of the building is calculated from experimental capacity curves of the individual walls idealized with bilinear elastic-perfectly plastic curves. The experimental capacity curves were obtained from in-plane cyclic loading tests on unreinforced and strengthened masonry walls with reinforced concrete jackets. The seismic action is compared with the load-bearing capacity of the building considering non-linear material behavior with its post-peak capacity. The application of the CSM to masonry buildings and the influence of a traditional strengthening method are demonstrated on the example of a public school building in Skopje, Macedonia.
In many historical centres in Europe, stone masonry buildings are part of building aggregates, which developed when the layout of the city or village was densified. In these aggregates, adjacent buildings share structural walls to support floors and roofs. Meanwhile, the masonry walls of the façades of adjacent buildings are often connected by dry joints since adjacent buildings were constructed at different times. Observations after for example the recent Central Italy earthquakes showed that the dry joints between the building units were often the first elements to be damaged. As a result, the joints opened up leading to pounding between the building units and a complicated interaction at floor and roof beam supports. The analysis of such building aggregates is very challenging and modelling guidelines do not exist. Advances in the development of analysis methods have been impeded by the lack of experimental data on the seismic response of such aggregates. The objective of the project AIMS (Seismic Testing of Adjacent Interacting Masonry Structures), included in the H2020 project SERA, is to provide such experimental data by testing an aggregate of two buildings under two horizontal components of dynamic
excitation. The test unit is built at half-scale, with a two-storey building and a one-storey building. The buildings share one common wall while the façade walls are connected by dry joints. The floors are at different heights leading to a complex dynamic response of this smallest possible building aggregate. The shake table test is conducted at the LNEC seismic testing facility. The testing sequence comprises four levels of shaking: 25%, 50%, 75% and 100% of nominal shaking table capacity. Extensive instrumentation, including accelerometers, displacement transducers and optical measurement systems, provides detailed information on the building aggregate response. Special attention is paid to the interface opening, the globa
A refined substructure technique in the frequency domain is developed, which permits consideration of the interaction effects among adjacent containers through the supporting deformable soil medium. The tank-liquid systems are represented by means of mechanical models, whereas discrete springs and dashpots stand for the soil beneath the foundations. The proposed model is employed to assess the responses of adjacent circular, cylindrical tanks for harmonic and seismic excitations over wide range of tank proportions and soil conditions. The influence of the number, spatial arrangement of the containers and their distance on the overall system's behavior is addressed. The results indicate that the cross-interaction effects can substantially alter the impulsive components of response of each individual element in a tank farm. The degree of this impact is primarily controlled by the tank proportions and the proximity of the predominant natural frequencies of the shell-liquid-soil systems and the input seismic motion. The group effects should be not a priori disregarded, unless the tanks are founded on shallow soil deposit overlying very stiff material or bedrock.
Past earthquakes demonstrated the high vulnerability of industrial facilities equipped with complex process technologies leading to serious damage of the process equipment and multiple and simultaneous release of hazardous substances in industrial facilities. Nevertheless, the design of industrial plants is inadequately described in recent codes and guidelines, as they do not consider the dynamic interaction between the structure and the installations and thus the effect of seismic response of the installations on the response of the structure and vice versa. The current code-based approach for the seismic design of industrial facilities is considered not enough for ensure proper safety conditions against exceptional event entailing loss of content and related consequences. Accordingly, SPIF project (Seismic Performance of Multi- Component Systems in Special Risk Industrial Facilities) was proposed within the framework of the European H2020 - SERA funding scheme (Seismology and Earthquake Engineering Research Infrastructure Alliance for Europe). The objective of the SPIF project is the investigation of the seismic behavior of a representative industrial structure equipped with complex process technology by means of shaking table tests. The test structure is a three-story moment resisting steel frame with vertical and horizontal vessels and cabinets, arranged on the three levels and connected by pipes. The dynamic behavior of the test structure and installations is investigated with and without base isolation. Furthermore, both firmly anchored and isolated components are taken into account to compare their dynamic behavior and interactions with each other. Artificial and synthetic ground motions are applied to study the seismic response at different PGA levels. After each test, dynamic identification measurements are carried out to characterize the system condition. The contribution presents the numerical simulations to calibrate the tests on the prototype, the experimental setup of the investigated structure and installations, selected measurement data and finally describes preliminary experimental results.
Past earthquakes demonstrated the high vulnerability of industrial facilities equipped with complex process technologies leading to serious damage of process equipment and multiple and simultaneous release of hazardous substances. Nonetheless, current standards for seismic design of industrial facilities are considered inadequate to guarantee proper safety conditions against exceptional events entailing loss of containment and related consequences. On these premises, the SPIF project -Seismic Performance of Multi-Component Systems in Special Risk Industrial Facilities- was proposed within the framework of the European H2020 SERA funding scheme. In detail, the objective of the SPIF project is the investigation of the seismic behaviour of a representative industrial multi-storey frame structure equipped with complex process components by means of shaking table tests. Along this main vein and in a performance-based design perspective, the issues investigated in depth are the interaction between a primary moment resisting frame (MRF) steel structure and secondary process components that influence the performance of the whole system; and a proper check of floor spectra predictions. The evaluation of experimental data clearly shows a favourable performance of the MRF structure, some weaknesses of local details due to the interaction between floor crossbeams and process components and, finally, the overconservatism of current design standards w.r.t. floor spectra predictions.
Seismic excited liquid filled tanks are subjected to extreme loading due to hydrodynamic pressures, which can lead to nonlinear stability failure of the thinwalled cylindrical tanks, as it is known from past earthquakes. A significant reduction of the seismically induced loads can be obtained by the application of base isolation systems, which have to be designed carefully with respect to the modified hydrodynamic behaviour of the tank in interaction with the liquid. For this reason a highly sophisticated fluid-structure interaction model has to be applied for a realistic simulation of the overall dynamic system. In the following, such a model is presented and compared with the results of simplified mathematical models for rigidly supported tanks. Finally, it is examined to what extent a simple mechanical model can represent the behaviour of a base isolated tank in case of seismic excitation
Seismic design of buried pipeline systems for energy and water supply is not only important for plant and operational safety but also for the maintenance of the supply infrastructure after an earthquake. The present paper shows special issues of the seismic wave impacts on buried pipelines, describes calculation methods, proposes approaches and gives calculation examples. This paper regards the effects of transient displacement differences and resulting tensions within the pipeline due to the wave propagation of the earthquake. However, the presented model can also be used to calculate fault rupture induced displacements. Based on a three-dimensional Finite Element Model parameter studies are performed to show the influence of several parameters such as incoming wave angle, wave velocity, backfill height and synthetic displacement time histories. The interaction between the pipeline and the surrounding soil is modeled with non-linear soil springs and the propagating wave is simulated affecting the pipeline punctually, independently in time and space. Special attention is given to long-distance heat pipeline systems. Here, in regular distances expansion bends are arranged to ensure movements of the pipeline due to high temperature. Such expansion bends are usually designed with small bending radii, which during the earthquake lead to high bending stresses in the cross-section of the pipeline. Finally, an interpretation of the results and recommendations are given for the most critical parameters.
Industrial units consist of the primary load-carrying structure and various process engineering components, the latter being by far the most important in financial terms. In addition, supply structures such as free-standing tanks and silos are usually required for each plant to ensure the supply of material and product storage. Thus, for the earthquake-proof design of industrial plants, design and construction rules are required for the primary structures, the secondary structures and the supply structures. Within the framework of these rules, possible interactions of primary and secondary structures must also be taken into account. Importance factors are used in seismic design in order to take into account the usually higher risk potential of an industrial unit compared to conventional building structures. Industrial facilities must be able to withstand seismic actions because of possibly wide-ranging damage consequences in addition to losses due to production standstill and the destruction of valuable equipment. The chapter presents an integrated concept for the seismic design of industrial units based on current seismic standards and the latest research results. Special attention is devoted to the seismic design of steel thin-walled silos and tank structures.
Industrial facilities must be thoroughly designed to withstand seismic actions as they exhibit an increased loss potential due to the possibly wideranging damage consequences and the valuable process engineering equipment. Past earthquakes showed the social and political consequences of seismic damage to industrial facilities and sensitized the population and politicians worldwide for the possible hazard emanating from industrial facilities. However, a holistic approach for the seismic design of industrial facilities can presently neither be found in national nor in international standards. The introduction of EN 1998-4 of the new generation of Eurocode 8 will improve the normative situation with
specific seismic design rules for silos, tanks and pipelines and secondary process components. The article presents essential aspects of the seismic design of industrial facilities based on the new generation of Eurocode 8 using the example of tank structures and secondary process components. The interaction effects of the process components with the primary structure are illustrated by means of the experimental results of a shaking table test of a three story moment resisting steel frame with different process components. Finally, an integrated approach of
digital plant models based on building information modelling (BIM) and structural health monitoring (SHM) is presented, which provides not only a reliable decision-making basis for operation, maintenance and repair but also an excellent tool for rapid assessment of seismic damage.
Reinforced concrete (RC) structures with masonry infills are widely used for several types of buildings all over the world. However, it is well known that traditional masonry infills constructed with rigid contact to the surrounding RC frame performed rather poor in past earthquakes. Masonry infills showed severe in-plane damages and failed in many cases under out-of-plane seismic loading. As the undesired interactions between frames and infills changes the load transfer on building level, complete collapses of buildings were observed. A possible solution is uncoupling of masonry infills to the frame to reduce the infill contribution activated by the frame deformation under horizontal loading. The paper presents numerical simulations on RC frames equipped with the innovative decoupling system INODIS. The system was developed within the European project INSYSME and allows an effective uncoupling of frame and infill. The simulations are carried out with a micro-modelling approach, which is able to predict the complex nonlinear behaviour resulting from the different materials and their interaction. Each brick is modelled individually and connected taking into account nonlinearity of a brick mortar interface. The calibration of the model is based on small specimen tests and experimental results for one bay one storey frame are used for the validation. The validated model is further used for parametric studies on two storey and two bay infilled frames. The response and change of the structural stiffness are analysed and compared to the traditionally infilled frame. The results confirm the effectiveness of the INODIS system with less damage and relatively low contribution of the infill at high drift levels. In contrast to the uncoupled system configurations, traditionally infilled frames experienced brittle failure at rather low drift levels.
Risk management for structures with a risk of explosion should be considered very carefully when performing a risk analysis according to IEC 62305-2. In contrast to the 2006 edition of the standard, the 2010 edition describes the topic “Structures with a risk of explosion” in more detail. Moreover, in Germany separate procedures and parameters are defined for the risk analysis of structures with a risk of explosion (Supplement 3 of the German DIN EN 62305-2 standard). This paper describes the contents and the relevant calculations of this Supplement 3, together with a numerical example.
Large scale central receiver systems typically deploy between thousands to more than a hundred thousand heliostats. During solar operation, each heliostat is aligned individually in such a way that the overall surface normal bisects the angle between the sun’s position and the aim point coordinate on the receiver. Due to various tracking error sources, achieving accurate alignment ≤1 mrad for all the heliostats with respect to the aim points on the receiver without a calibration system can be regarded as unrealistic. Therefore, a calibration system is necessary not only to improve the aiming accuracy for achieving desired flux distributions but also to reduce or eliminate spillage. An overview of current larger-scale central receiver systems (CRS), tracking error sources and the basic requirements of an ideal calibration system is presented. Leading up to the main topic, a description of general and specific terms on the topics heliostat calibration and tracking control clarifies the terminology used in this work. Various figures illustrate the signal flows along various typical components as well as the corresponding monitoring or measuring devices that indicate or measure along the signal (or effect) chain. The numerous calibration systems are described in detail and classified in groups. Two tables allow the juxtaposition of the calibration methods for a better comparison. In an assessment, the advantages and disadvantages of individual calibration methods are presented.
The investigation of atomic resonance fluorescence has always been of special interest as a means for the determination of atomic parameters. In addition, information on the interaction mechanism between atoms and radiation can be obtained. In the standard fluorescence experiment the frequency distribution of the incident photons is larger than the natural width of the respective transition; as a consequence the correlation time in the photon-atom interaction is determined by the lifetime of the atoms in the excited state. With the development of lasers and especially of tunable dye lasers in recent years it became possible to study the case where the incident radiation has a spectral distribution which is narrower than the natural width. This corresponds to a correlation time of the incoming light wave which is much longer than the excited-state lifetime. In this chapter a survey of experiments on the resonance fluorescence of atoms in monochromatic laser fields will be given.