Fachbereich Energietechnik
Refine
Year of publication
- 2010 (35) (remove)
Institute
Has Fulltext
- no (35)
Document Type
- Conference Proceeding (13)
- Article (12)
- Conference: Meeting Abstract (5)
- Part of a Book (4)
- Book (1)
Keywords
- Cardiovascular MRI (1)
- Left ventriular function (1)
- MR-stethoscope (1)
- Magnetic field strength (1)
- Magnetic resonance imaging (MRI) (1)
- arresters (1)
- atmospheric modeling (1)
- conductors (1)
- lightning (1)
- lightning protection (1)
4CH TX/RX Surface Coil for 7T: Design, Optimization and Application for Cardiac Function Imaging
(2010)
Practical impediments of ultra high field cardiovascular MR (CVMR) can be catalogued in exacerbated magnetic field and radio frequency (RF) inhomogeneities, susceptibility and off-resonance effects, conductive and dielectric effects in tissue, and RF power deposition constraints, which all bear the potential to spoil the benefit of CVMR at 7T. Therefore, a four element cardiac transceive surface coil array was developed. Cardiac imaging provided clinically acceptable signal homogeneity with an excellent blood myocardium contrast. Subtle anatomic structures, such as pericardium, mitral and tricuspid valves and their apparatus, papillary muscles, and trabecles were accurately delineated.
As high-field cardiac MRI (CMR) becomes more widespread the propensity of ECG to distortions and mistriggering increases and with it the motivation for a cardiac triggering alternative. Hence, this study explores the suitability of acoustic cardiac triggering (ACT) for left ventricular (LV) function assessment in healthy subjects at 1.5T and 3.0T.
High Spatial Resolution 3D MRI of the Larynx Using a Dedicated TX/RX Phased Array Coil at 7.0T
(2010)
MRI holds great potential for elucidating laryngeal and vocal fold anatomy together with the assessment of physiological processes associated in human phonation. However, MRI of human phonation remains very challenging due to the small size of the targeted structures, interfering signal from fat, air between the vocal folds and surrounding muscles and physiological motion. These anatomical/physiological constraints translate into stringent technical requirements in balancing, scan time, image contrast, immunity to physiological motion, temporal resolution and spatial resolution. Motivated by these challenges and limitations this study is aiming at translating the sensitivity gain at ultra-high magnetic fields for enhanced high spatial resolution 3D imaging of the larynx and vocal tract. To approach this goal a dedicated two channel TX/RX larynx coil is being proposed.
Objective: As high-field cardiac MRI (CMR) becomes more widespread the propensity of ECG to interference from electromagnetic fields (EMF) and to magneto-hydrodynamic (MHD) effects increases and with it the motivation for a CMR triggering alternative. This study explores the suitability of acoustic cardiac triggering (ACT) for left ventricular (LV) function assessment in healthy subjects (n=14). Methods: Quantitative analysis of 2D CINE steady-state free precession (SSFP) images was conducted to compare ACT’s performance with vector ECG (VCG). Endocardial border sharpness (EBS) was examined paralleled by quantitative LV function assessment. Results: Unlike VCG, ACT provided signal traces free of interference from EMF or MHD effects. In the case of correct Rwave recognition, VCG-triggered 2D CINE SSFP was immune to cardiac motion effects—even at 3.0 T. However, VCG-triggered 2D SSFP CINE imaging was prone to cardiac motion and EBS degradation if R-wave misregistration occurred. ACT-triggered acquisitions yielded LV parameters (end-diastolic volume (EDV), endsystolic volume (ESV), stroke volume (SV), ejection fraction (EF) and left ventricular mass (LVM)) comparable with those derived fromVCG-triggered acquisitions (1.5 T: ESVVCG=(56± 17) ml, EDVVCG=(151±32)ml, LVMVCG=(97±27) g, SVVCG=(94± 19)ml, EFVCG=(63±5)% cf. ESVACT= (56±18) ml, EDVACT=(147±36) ml, LVMACT=(102±29) g, SVACT=(91± 22) ml, EFACT=(62±6)%; 3.0 T: ESVVCG=(55±21) ml, EDVVCG=(151±32) ml, LVMVCG=(101±27) g, SVVCG=(96±15) ml, EFVCG=(65±7)% cf. ESVACT=(54±20) ml, EDVACT=(146±35) ml, LVMACT= (101±30) g, SVACT=(92±17) ml, EFACT=(64±6)%). Conclusions: ACT’s intrinsic insensitivity to interference from electromagnetic fields renders
We analyze the influence of dipole-dipole interactions in an electromagnetically induced transparency set up for a density at the onset of cooperative effects. To this end, we include mean-field models for the influence of local-field corrections and radiation trapping into our calculation. We show both analytically and numerically that the polarization contribution to the local field strongly modulates the phase of a weak pulse. We give an intuitive explanation for this local-field-induced phase modulation and demonstrate that it distinctively differs from the nonlinear self-phase-modulation that a strong pulse experiences in a Kerr medium.
Moderne Bauwerke müssen heute eine hohe energetische Leistungsfähigkeit aufweisen und gleichzeitig alle einwirkenden Lasten sicher abtragen. Dies stellt insbesondere in Erdbebengebieten hohe Anforderungen an die verwendeten Baustoffe. Am baupraktischen Beispiel einer Doppelhaushälfte wird demonstriert, dass die Symbiose aus energieeffizientem und gleichzeitig erdbebensicherem Bauen in der höchsten deutschen Erdbebenzone mit monolithischem Ziegelmauerwerk gut realisierbar ist. Als Ziegelmauerwerk werden für die Außenwände wärmetechnisch optimierte Hochlochziegel verwendet, die sowohl die Anforderungen der Energieeinsparverordnung 2009 als auch die Anforderungen an Mauerwerkbaustoffe nach den aktuellen Erdbebennormen erfüllen. Der Erdbebennachweis der Doppelhaushälfte erfolgt mit einem nichtlinearen Nachweisverfahren, das für eine einfache praktische Anwendung programmtechnisch umgesetzt wurde. Für den Nachweis wurden aus zyklischen Schubwandversuchen ermittelte Last-Verformungskurven verwendet. Das gesamte in Deutschland noch nicht normativ geregelte Nachweiskonzept wurde im Rahmen einer Zustimmung im Einzelfall geprüft und genehmigt.
Die Erdbebensicherheit von Gebäuden aus Kalksandsteinmauerwerk ist aktuell nach DIN 4149 mit linearen Verfahren nachzuweisen. Dies führt in der praktischen Anwendung zu großen Problemen, da selbst traditionell übliche Grundrisse teilweise nicht mehr ohne zusätzliche Maßnahmen nachweisbar sind. Zur Lösung dieser Problematik wurden von der deutschen Mauerwerksindustrie auf nationaler und europäischer Ebene Forschungsprojekte initiiert, deren Ergebnisse in Form von statisch nichtlinearen Verfahren Eingang in den Nationalen Anhang zur DIN EN 1998-1 [12] gefunden haben. Mit den Verfahren wird die Nachweissituation zukünftig grundlegend verbessert, da mit diesen die Tragwerksreserven wesentlich besser ausgenutzt werden können. Im Folgenden wird die Anwendung der Verfahren am Beispiel einer Reihenhauszeile aus Kalksandsteinmauerwerk demonstriert. Der Nachweis der Reihenhäuser wurde im Rahmen einer Zustimmung im Einzelfall, die vom Bundesverband Kalksandsteinindustrie eV in Hannover koordiniert wurde, durch unabhängige Gutachter und die Bauaufsicht eingehend geprüft und für richtig befunden. Die Durchführung des Nachweises erfolgte auf Grundlage eines an der RWTH Aachen entwickelten neuen Nachweiskonzeptes. Die baupraktische Anwendbarkeit und einfache Nachvollziehbarkeit dieses Konzepts ist durch eine softwaretechnische Umsetzung sichergestellt.