Fachbereich Energietechnik
Refine
Year of publication
Institute
- Fachbereich Energietechnik (1067)
- Nowum-Energy (55)
- Solar-Institut Jülich (42)
- INB - Institut für Nano- und Biotechnologien (26)
- ECSM European Center for Sustainable Mobility (16)
- Kommission für Forschung und Entwicklung (14)
- Fachbereich Chemie und Biotechnologie (5)
- Fachbereich Medizintechnik und Technomathematik (5)
- Fachbereich Bauingenieurwesen (4)
- Fachbereich Elektrotechnik und Informationstechnik (3)
Has Fulltext
- no (1067) (remove)
Language
- English (562)
- German (502)
- Multiple languages (1)
- Dutch (1)
- Spanish (1)
Document Type
- Article (593)
- Conference Proceeding (230)
- Book (126)
- Part of a Book (83)
- Doctoral Thesis (10)
- Conference: Meeting Abstract (8)
- Report (7)
- Other (4)
- Talk (2)
- Contribution to a Periodical (1)
Keywords
- Earthquake (5)
- Diversity Management (4)
- Energy storage (4)
- Power plants (4)
- Seismic design (4)
- Associated liquids (3)
- Concentrated solar power (3)
- Hybrid energy system (3)
- INODIS (3)
- Out-of-plane load (3)
- Seismic loading (3)
- earthquakes (3)
- Adjacent buildings (2)
- Central receiver power plant (2)
- Concentrated systems (2)
- Diversity (2)
- Electricity generation (2)
- Energierecht (2)
- Engineering Habitus (2)
- Gas turbine (2)
- Historical centres (2)
- Human-robot collaboration (2)
- INSYSME (2)
- Innovation Management (2)
- Masonry infill (2)
- Organizational Culture (2)
- Shake table test (2)
- Solar thermal technologies (2)
- Stone masonry (2)
- Tanks (2)
- cyber physical production system (2)
- digital shadow (2)
- engineering education (2)
- industrial facilities (2)
- installations (2)
- piping (2)
- seismic design (2)
- seismic loading (2)
- Academia (1)
- Acceptance (1)
- Anti-Bias (1)
- Antibias (1)
- Artificial intelligence (1)
- Ausfachungsmauerwerk (1)
- BIM (1)
- Basisisolierung (1)
- Bauwerksüberwachung (1)
- Behaviour factor q (1)
- Bemessung (1)
- Best practice sharing (1)
- Blind prediction competition (1)
- Bloom Taxonomy (1)
- COMSOL Multiphysics (1)
- Camera system (1)
- Capacity Curve (1)
- Cardiovascular MRI (1)
- Central receiver system (1)
- Ceramics (1)
- Change Management (1)
- Change management (1)
- Civil engineering (1)
- Cloud passages (1)
- Cognitive assistance system (1)
- Components (1)
- Concentrated solar collector (1)
- Concentrating solar power (1)
- Control optimization (1)
- Corporate Culture (1)
- DAC (1)
- DIN EN 1996 (1)
- DNI forecast (1)
- DNI forecasting (1)
- Decision theory (1)
- Decoupling (1)
- Design Thinking (1)
- Design examples (1)
- Digital leadership (1)
- Digitalization (1)
- Direct normal irradiance forecast (1)
- District data model (1)
- District energy planning platform (1)
- Diversity management (1)
- Dynamic simulation (1)
- EN 1998-4 (1)
- ESHM20, industrial facilities (1)
- Earthquake Engineering (1)
- Electrochemistry (1)
- Elektrizität (1)
- Emilia-Romagna earthquake (1)
- Emissionshandel (1)
- Empirical consequence curves (1)
- Empirical fragility functions (1)
- Energiekonzept (1)
- Energy system (1)
- Energy system planning (1)
- Engineering (1)
- Engineering Education (1)
- Erdbeben (1)
- Erdbebeneinwirkung (1)
- Erneuerbares Energiengesetz (1)
- Ethics (1)
- Eurocode 8 (1)
- Feuchtigkeit (1)
- Fracture classification (1)
- Frame structure (1)
- Fresnel power plant (1)
- Future Skills (1)
- Future skills (1)
- Gas (1)
- Gender (1)
- Genetic algorithm (1)
- Germany (1)
- Gesamtwassergehalt (1)
- Global change (1)
- Gust wind response (1)
- Heliostat Field Calibration (1)
- Heliostats (1)
- Higher Education (1)
- Hilbert Room (1)
- Human factors (1)
- Human-centered work design (1)
- Hybridization (1)
- Imaging (1)
- In- plane damage (1)
- In-plane (1)
- In-plane load (1)
- In-plane performance, isolation (1)
- Inclusive work climate (1)
- Industrial facilities (1)
- Industrial units (1)
- Infill wall design (1)
- Innovation (1)
- Interaction (1)
- Interculturality (1)
- Interdisciplinarity (1)
- Isolation (1)
- Key competences (1)
- Leadership (1)
- Left ventriular function (1)
- Lightning protection system (1)
- Linear elastic analysis (1)
- LiveLink for MATLAB (1)
- MR-stethoscope (1)
- Magnetic field strength (1)
- Magnetic resonance imaging (MRI) (1)
- Masonry partition walls (1)
- Masonry structures (1)
- Mauerwerksbauten (1)
- Mauerwerksgebäude (1)
- Measuring instruments (1)
- Mixed integer linear programming (MILP) (1)
- Modern constructions (1)
- Molten salt receiver (1)
- Molten salt receiver system (1)
- Molten salt receiver system, (1)
- Molten salt solar tower (1)
- Momentenverteilung (1)
- Monitoring (1)
- Monte Carlo Tree Search (1)
- Morphing (1)
- Multi-storey (1)
- Neo-Deterministic (1)
- Nowcasting (1)
- Numerical modelling (1)
- Operators (1)
- Optimization module (1)
- Organizational culture (1)
- Out-of-plane (1)
- Out-of-plane capacity (1)
- Out-of-plane failure (1)
- Out-of-plane strength (1)
- PBEE (1)
- PTC (1)
- Parabolic trough collector (1)
- Perception (1)
- Photovoltaics (1)
- Piping (1)
- Postulates (1)
- Power conversion systems (1)
- Precast buildings (1)
- Privacy (1)
- Probability distribution mapping (1)
- Process prediction (1)
- Psychological concepts (1)
- Pushover analysis (1)
- PushoverAnalysen (1)
- Quadrocopter (1)
- Quantenmechanik (1)
- RC frames (1)
- Rahmentragwirkung (1)
- Reinforced concrete frame (1)
- Renewable energy (1)
- Renewable energy integration (1)
- Response spectrum (1)
- Responsibility (1)
- Schrödingers cat (1)
- Seismic (1)
- Seismic Hazard (1)
- Sensor (1)
- Shoulder (1)
- Silos (1)
- Slab deflection (1)
- Social impact measurement (1)
- Solar concentration (1)
- Solar dish (1)
- Solar irradiance (1)
- Spectral analysis (1)
- Stahlbetonrahmen (1)
- Star design (1)
- Structural design (1)
- Structural health monitoring (1)
- Sustainability (1)
- Sustainable engineering education (1)
- Tank (1)
- Thermal Energy Storage (1)
- Time-series aggregation (1)
- Transient flux distribution (1)
- Two-phase modelling (1)
- Typical periods (1)
- UAV (1)
- Uncertainty analysis (1)
- Unmanned aerial vehicle (1)
- Unreinforced masonry buildings (1)
- Unreinforced masonry walls (1)
- Verdunstungskälte (1)
- Verhaltensbeiwerte (1)
- Vulnerability Curves (1)
- Wand-Decken-Interaktion (1)
- Wellenausbreitung (1)
- Wind turbulence (1)
- Window opening (1)
- Ziegelmauerwerk (1)
- antennas (1)
- arresters (1)
- atmospheric modeling (1)
- behaviour factor q (1)
- best practice (1)
- body limbs (1)
- bullying (1)
- carbon dioxide removal (1)
- cardiac gating (1)
- cardiovascular MR imaging (1)
- change management (1)
- churches (1)
- climate neutrality (1)
- concentrating collector (1)
- conductors (1)
- connection detail (1)
- cyber-physical production system (1)
- deserts (1)
- digital twin (1)
- digitalization (1)
- direct air capture (1)
- dissemination (1)
- diversity (1)
- diversity management (1)
- down-conductor (1)
- early warning and response system (1)
- earthquake (1)
- earthquake engineering (1)
- economics (1)
- education (1)
- elastomeric bearing (1)
- electrical circuits (1)
- electrical engineering (1)
- electrocardiogram (1)
- energy concept (1)
- energy transition (1)
- engineering (1)
- equivalent stiffness (1)
- field simulation (1)
- finite element method (1)
- fluid structure interaction (1)
- fragility curves (1)
- friction pendulum bearing (1)
- gender and diversity (1)
- granular silo (1)
- high field MR imaging (1)
- high-frequency technology (1)
- human digital shadow (1)
- human factors (1)
- human-machine interface (1)
- hypoplasticity (1)
- impulsive effects (1)
- in-plane (1)
- in-plane and out-of-plane failure (1)
- in-plane behaviour (1)
- innovation (1)
- innovation management (1)
- integration SHM in BIM (1)
- interconnected sensor systems (1)
- internet of production (1)
- lessons learned (1)
- lightning (1)
- lightning protection (1)
- linear elastic analysis; (1)
- liquid storage tank (1)
- liquid-storage tank (1)
- liquid-structure interaction (1)
- lizards (1)
- macro-element (1)
- magnetic resonance imaging (1)
- masonry infill (1)
- masonry structures (1)
- metal façade (1)
- microwave technology (1)
- modern constructions (1)
- negative emissions (1)
- nonlinear transient analyses (1)
- open educational resources (1)
- out-of-plane (1)
- out-of-plane behaviour (1)
- phonocardiogram (1)
- planning (1)
- plasma technology (1)
- point-focussing system (1)
- policy recommendations (1)
- power generation (1)
- power transmission lines (1)
- probability distribution (1)
- raytracing (1)
- recommendations for actions (1)
- renewable energies (1)
- research association (1)
- rollout (1)
- safety control (1)
- seismic (1)
- seismic hazard (1)
- seismic isolation (1)
- seismic response (1)
- seismic risk (1)
- seismic structural damage detection via SHM (1)
- seismic vulnerability (1)
- simplified approach (1)
- social responsible engineering (1)
- solar process heat (1)
- standards (1)
- steel columns (1)
- storage dispatch (1)
- storage optimisation (1)
- structure-soil-structure interaction (1)
- surges (1)
- swimming (1)
- teaching (1)
- thermal storage (1)
- touch voltage (1)
- truss (1)
- unreinforced masonry buildings (1)
- user & usage (1)
- vault (1)
- vocal fold oscillation (1)
- wave propagation (1)
The proposed Den Haag Zuidwest district heating system of the city of The Hague consists of a deep doublet in a Jurassic sandstone layer that is designed for a production temperature of 75 °C and a reinjection temperature of 40 °C at a flow rate of 150 m3 h−1. The prediction of reservoir temperature and production behavior is crucial for success of the proposed geothermal doublet. This work presents the results of a study of the important geothermal and geohydrological issues for the doublet design. In the first phase of the study, the influences of the three-dimensional (3D) structures of anticlines and synclines on the temperature field were examined. A comprehensive petrophysical investigation was performed to build a large scale 3D-model of the reservoir. Several bottomhole temperatures (BHTs), as well as petrophysical logs were used to calibrate the model using thermal conductivity measurements on 50 samples from boreholes in different lithological units in the study area. Profiles and cross sections extracted from the calculated temperature field were used to study the temperature in the surrounding areas of the planned doublet. In the second phase of the project, a detailed 3D numerical reservoir model was set up, with the aim of predicting the evolution of the producer and injector temperatures, and the extent of the cooled area around the injector. The temperature model from the first phase provided the boundary conditions for the reservoir model. Hydraulic parameters for the target horizons, such as porosity and permeability, were taken from data available from the nearby exploration wells. The simulation results are encouraging as no significant thermal breakthrough is predicted. For the originally planned location of the producer, the extracted water temperature is predicted to be around 79 °C, with an almost negligible cooling in the first 50 years of production. When the producer is located shallower parts of the reservoir, the yield water temperatures is lower, starting at ≈76 °C and decreasing to ≈74 °C after 50 years of operation. This comparatively larger decrease in temperature with time is caused by the structural feature of the reservoir, namely a higher dip causes the cooler water to easily move downward. In view of the poor reservoir data, the reservoir simulation model is constructed to allow iterative updates using data assimilation during planned drilling, testing, and production phases. Measurements during an 8 h pumping test carried out in late 2010 suggest that a flow rate of 150 m3 h−1 is achievable. Fluid temperatures of 76.5 °C were measured, which is very close to the predicted value.
The Effect of Openings on Out-of-Plane Capacity of Masonry Infilled Reinforced Concrete Frames
(2018)
Cryopumps without liquid nitrogen shielding are used to provide a vacuum of 10−6 torr in the spectrometer. The vacuum system is subdivided in three sections that can be separated by valves.
The first section (scattering chamber) has a volume of 60 l, two rotation transmissions with 35 cm dia and a sliding seal that allows a rotation of 160° without deteriorating the vacuum. The second section includes the vacuum chambers inside the magnets with 6 × 80 cm cross-section and a length of 1200 cm. The third section (detector box) has a volume of 4300 l and contains a moveable detector system. The gas inside the detector with a pressure of 760 torr is separated from the vacuum by a 15 μm mylar foil with an area of 300 cm2. The detector box can be valved off by a valve with the dimension of 10 × 100 cm.
The layout of system is given. The instrumentation and the interlock system are described. First experiences with this system are presented.
With proven impact of statistical fracture analysis on fracture classifications, it is desirable to minimize the manual work and to maximize repeatability of this approach. We address this with an algorithm that reduces the manual effort to segmentation, fragment identification and reduction. The fracture edge detection and heat map generation are performed automatically. With the same input, the algorithm always delivers the same output. The tool transforms one intact template consecutively onto each fractured specimen by linear least square optimization, detects the fragment edges in the template and then superimposes them to generate a fracture probability heat map.
We hypothesized that the algorithm runs faster than the manual evaluation and with low (< 5 mm) deviation. We tested the hypothesis in 10 fractured proximal humeri and found that it performs with good accuracy (2.5 mm ± 2.4 mm averaged Euclidean distance) and speed (23 times faster). When applied to a distal humerus, a tibia plateau, and a scaphoid fracture, the run times were low (1–2 min), and the detected edges correct by visual judgement. In the geometrically complex acetabulum, at a run time of 78 min some outliers were considered acceptable. An automatically generated fracture probability heat map based on 50 proximal humerus fractures matches the areas of high risk of fracture reported in medical literature.
Such automation of the fracture analysis method is advantageous and could be extended to reduce the manual effort even further.
The adsorption of fluor-carbon complexes on GaAs(110) studied by electron energy loss spectroscopy
(1986)
Textile reinforced concrete. Part I: Process model for collaborative research and development
(2003)
The Solar-Institute Jülich (SIJ) has initiated the construction of the first and only German solar tower power plant and is now involved in the accompanying research. The power plant for experimental and demonstration purposes in the town of Jülich started supplying electric energy in the beginning of 2008. The central receiver plant features as central innovation an open volumetric receiver, consisting of porous ceramic elements that simultaneously absorb the concentrated sunlight and transfer the heat to ambient air passing through the pores so that an average temperature of 680°C is reached. The subsequent steam cycle generates up to 1.5 MWe. A main field of research at the SIJ is the optimization of the absorber structures. To analyze the capability of new absorber specimens a special test facility was developed and set up in the laboratory. A high-performance near-infrared radiator offers for single test samples a variable and repeatable beam with a power of up to 320 kW/m² peak. The temperatures achieved on the absorber surface can reach more than 1000°C. To suck ambient air through the open absorber - like on the tower - it is mounted on a special blower system. An overview about the test facility and some recent results will be presented.