Fachbereich Elektrotechnik und Informationstechnik
Refine
Year of publication
- 2012 (41) (remove)
Institute
Document Type
- Article (16)
- Conference Proceeding (13)
- Conference: Meeting Abstract (5)
- Book (2)
- Part of a Book (2)
- Patent (2)
- Doctoral Thesis (1)
Keywords
- Gleichspannungswandler (1)
- IP-based networks (1)
- IndraMotion (1)
- MATLAB , MLPI , Motion control , Open Core , industrial drives , rapid control prototypin , sercos automation bus (1)
- Motion-Logic System (1)
- NGN (1)
- SPS (1)
- Speicherprogrammierte Steuerung (1)
- Wärmeübertragung (1)
- next generation network (1)
- product bundling (1)
- telecommunication (1)
Security Awareness ist derzeit ein viel diskutiertes Thema. Es reicht nicht, einfach nur ein paar technische Systeme (z.B. Firewalls) zu installieren, um ein angemessenes Schutzniveau zu erzielen. Neben einer guten Organisation von IT Security ist es auch notwendig, den Mitarbeiter einzubinden. Der vielzitierte "Faktor Mensch" ist derjenige, der die Technik korrekt anwenden muss und der durch falsches Verhalten technische und organisatorische Schutzmaßnahmen aushebeln kann. Deshalb reicht es nicht aus, wenn sich der Mitarbeiter der Gefahren bewusst ("aware") ist, er muss auch dementsprechend "sicher" handeln.
Mit freundlicher Genehmigung der Autoren und des Oldenbourg Industrieverlags https://www.oldenbourg-industrieverlag.de/de/9783835633223-33223 erschienen als Beitrag im Tagungsband zur AALE-Tagung 2012. 9. Fachkonferenz 4.-5. Mai 2012, Aachen, Fachhochschule. ISBN 9783835633223 S 6-2. S. 165-174 Zusammenfassung der Autoren: "Abschließend kann festgehalten werden, dass die gesamten durchgeführten Überlegungen von den Messergebnissen der Inbetriebnahme positiv bestätigt werden. Es wird durch diese Topologie eine maximale Systemverfügbarkeit garantiert und die Zellen werden optimal betrieben. Ein Blick in die Zukunft für dieses Projekt zeigt viele Erweiterungs- und Optimierungsaufgaben. So muss der DC/DC-Wandler für einen bidirektionalen Betrieb erweitert werden, um einen Rekuperationsbetrieb zu gewährleisten bzw. die Zellen laden zu können. Dadurch können gleichzeitig die Gleichrichterdioden im Sekundärleistungsteil durch IGBTs oder MOSFETs ersetzt werden. Die voll funktionsfähige Version des DC/DC-Wandlers könnte höchstwahrscheinlich direkt auf die Anschlusspole der Zelle montiert werden, wodurch das Gewicht gesenkt wird. Durch die verringerte Verlustleistung in den Zuleitungen könnte der Wirkungsgrad noch einmal gesteigert werden.
This contribution discusses the utilization of RF power in an MRI system with RF mode shimming which enables the superposition of circularly polarized modes of a transmit RF coil array driven by a Butler matrix. Since the required power for the individual modes can vary widely, mode-shimming can result in a significant underutilization of the total available RF power. A variable power combiner (VPC) is proposed to improve the power utilization: it can be realized as a reconfiguration of the MRI transmit system by the inclusion of one additional matrix network which receives the power from all transmit amplifiers at its input ports and provides any desired (combined) power distribution at its output ports by controlling the phase and amplitude of the amplifiers’ input signals. The power distribution at the output ports of the VPC is then fed into the “mode” ports of the coil array Butler matrix in order to superimpose the spatial modes at the highest achievable power utilization. The VPC configuration is compared to the standard configuration of the transmit chain of our MRI system with 8 transmit channels and 16 coils. In realistic scenarios, improved power utilization was achieved from 17% to 60% and from 14% to 55% for an elliptical phantom and a region of interest in the abdomen, respectively, and an increase of the power utilization of 1 dB for a region of interest in the upper leg. In general, it is found that the VPC allows significant improvement in power utilization when the shimming solution demands only a few modes to be energized, while the technique can yield loss in power utilization in cases with many modes required at high power level.
If we think about applications for modern Power MOSFETs using trench technology, running them in linear mode may not be top of the priority list. Yet there are multiple uses for Trench Power MOSFETs in linear mode. In fact, even turning the device on and off in switching applications is a form of linear operation. Also, these components can be run in linear mode to protect the device against voltage surges. This article will illustrate the factors that need to be considered for linear operation and show how Trench Power MOSFETs are suited to it.
Mit freundlicher Genehmigung der Autoren und des Oldenbourg Industrieverlags https://www.oldenbourg-industrieverlag.de/de/9783835633223-33223 erschienen als Beitrag im Tagungsband zur AALE-Tagung 2012. 9. Fachkonferenz 4.-5. Mai 2012, Aachen, Fachhochschule. ISBN 9783835633223 S 2-1 S. 37-46 Original-Abstract der Autoren: "Dieser Artikel beschreibt eine universelle Programmierschnittstelle zur Entwicklung von Motion-Logic Applikationen für industrielle Motion-Controller. Sie ermöglicht die Entwicklung von Software mit modernen Hochsprachen, wie C/C++. Visual Basic, C#, Java, Objective-Cund visuellen Programmiersprachen, wie LabVIEW in Koexistenz mit klassischen Programmiersprachen für speicherprogrammierbare Steuerungen nach IEC 61131-3. Daraus ergeben sich neue Möglichkeiten industrielle Antriebs- und Steuerungssysteme mit ihrem IT-Umfeld zu verbinden."
Die Veränderungen des Telekommunikationsmarktes haben in der Praxis zu einer Vielzahl von Transformationsprojekten geführt. Was gehört aber zu einem “Transformationsprojekt”, welche Prozesse und Systeme werden verändert? Zur Beantwortung dieser Frage haben wir 184 Berichte zu Projekten analysiert, die als "Transformationsprojekte" bezeichnet waren. Für die Analyse haben wir einen Kodierungsrahmen konzipiert und anhand dessen die Berichte mit einem hierarchischen Clustering-Verfahren in Themen gruppiert. Die Ergebnisse liefern Hinweise über die in der Praxis gesetzten Schwerpunkte und Prioritäten. Sie können
somit als Unterstützung für Unternehmen dienen, die ein Transformationsprojekt planen. Sie weisen zudem darauf hin, in welchen Bereichen eines Unternehmens Unterstützung durch wissenschaftlich erprobte Werkzeuge und Modelle nötig ist.