Fachbereich Elektrotechnik und Informationstechnik
Refine
Year of publication
- 2024 (3)
- 2023 (3)
- 2022 (5)
- 2021 (6)
- 2020 (10)
- 2019 (9)
- 2018 (13)
- 2017 (8)
- 2016 (14)
- 2015 (8)
- 2014 (13)
- 2013 (13)
- 2012 (16)
- 2011 (25)
- 2010 (21)
- 2009 (23)
- 2008 (29)
- 2007 (22)
- 2006 (23)
- 2005 (20)
- 2004 (27)
- 2003 (14)
- 2002 (16)
- 2001 (13)
- 2000 (25)
- 1999 (20)
- 1998 (18)
- 1997 (29)
- 1996 (16)
- 1995 (19)
- 1994 (19)
- 1993 (16)
- 1992 (12)
- 1991 (11)
- 1990 (8)
- 1989 (13)
- 1988 (10)
- 1987 (5)
- 1986 (6)
- 1985 (9)
- 1984 (2)
- 1983 (3)
- 1982 (2)
- 1981 (3)
- 1980 (8)
- 1979 (4)
- 1978 (7)
- 1977 (1)
- 1976 (6)
- 1975 (2)
- 1974 (4)
- 1973 (1)
- 1972 (3)
- 1970 (1)
Institute
Document Type
- Article (637) (remove)
Keywords
- Multimediamarkt (6)
- Hot S-parameter (2)
- Literaturanalyse (2)
- MINLP (2)
- Referenzmodellierung (2)
- 197m/gHg (1)
- 3-D printing (1)
- Anwendungsorientierter Forschungsansatz (1)
- Arbeit 4.0 (1)
- Automated driving (1)
Dielectric Properties of Polyolefins Stressed by High Electrical Fields. Fruth, B. ; Krause, G.
(1987)
Dielectric Properties of Polyolefins Stressed by High Electrical Fields / Fruth, B. ; Krause, G.
(1988)
In: Unterrichtsblätter / Deutsche Telekom AG. 53. 2000. 7. S. 326-340. (15 S. ) Die Multimedia-Dienste erhalten durch die Datenreduktion bei der Kompressionstechnologie eine Wirtschaftlichkeit, die den breiteren Einsatz von breitbandigen Diensten erlaubt. Die Dienste benötigen für die verschiedenen Medien nicht mehr so große Übertragungs- und Speicherleistungen. Bei den entwickelten Verfahren, den so genannten MPEG-(Motion Picture Experts Group-)Standards, werden die Video- und Tonsignale in die digitale Ebene überführt und anschließend unrelevante Signalanteile entfernt. Der daraus resultierende Datenstrom benötigt weniger Bandbreite bei der Übertragung zum Endkunden. Die MPEG-Organisation wurde bereits im Jahre 1988 ins Leben gerufen und ist ein gemeinsames Gremium der beiden Organisationen ISO (International Standard Organization) und IEC (International Electrotechnical Commission), welches sich mit der Standardisierung von Kodier- und Kompressionsverfahren für die digitalen Bild-, Video und Audioformate befasst. Mittlerweile sind vier wichtige Standards mit MPEG-1, MPEG-2 und MPEG-4 verabschiedet worden sowie mit MPEG-7 in Vorbereitung. Da die Grundlagen zu MPEG-1, -2 und -Audio bereits in anderen Beiträgen behandelt wurden, werden hier ausschließlich die neuen bzw. aktuellen MPEG-Standards vorgestellt.
Im Rahmen der Digitalisierung ist die zunehmende Automatisierung von bisher manuellen Prozessschritten ein Aspekt, der massive Auswirkungen auf die zukünftige Arbeitswelt haben wird. In diesem Kontext werden an den Einsatz von Softwarerobotern zur Prozessautomatisierung hohe Erwartungen geknüpft. Bei den Implementierungsansätzen wird die Diskussion aktuell insbesondere durch Robotic Process Automation (RPA) und Chatbots geprägt. Beide Ansätze verfolgen das gemeinsame Ziel einer 1:1-Automatisierung von menschlichen Handlungen und dadurch ein direktes Ersetzen von Mitarbeitern durch Maschinen. Bei RPA werden Prozesse durch Softwareroboter erlernt und automatisiert ausgeführt. Dabei emulieren RPA-Roboter die Eingaben auf der bestehenden Präsentationsschicht, so dass keine Änderungen an vorhandenen Anwendungssystemen notwendig sind. Am Markt werden bereits unterschiedliche RPA-Lösungen als Softwareprodukte angeboten. Durch Chatbots werden Ein- und Ausgaben von Anwendungssystemen über natürliche Sprache realisiert. Dadurch ist die Automatisierung von unternehmensexterner Kommunikation (z. B. mit Kunden) aber auch von unternehmensinternen Assistenztätigkeiten möglich. Der Beitrag diskutiert die Auswirkungen von Softwarerobotern auf die Arbeitswelt anhand von Anwendungsbeispielen und erläutert die unternehmensindividuelle Entscheidung über den Einsatz von Softwarerobotern anhand von Effektivitäts- und Effizienzzielen.
Die Airysche Spannungsfunktion für die unendliche anisotrope, orthotrope und isotrope Scheibe
(1980)
Objective
The purpose of this study is to (i) design a small and mobile Magnetic field ALert SEnsor (MALSE), (ii) to carefully evaluate its sensors to their consistency of activation/deactivation and sensitivity to magnetic fields, and (iii) to demonstrate the applicability of MALSE in 1.5 T, 3.0 T and 7.0 T MR fringe field environments.
Methods
MALSE comprises a set of reed sensors, which activate in response to their exposure to a magnetic field. The activation/deactivation of reed sensors was examined by moving them in/out of the fringe field generated by 7TMR.
Results
The consistency with which individual reed sensors would activate at the same field strength was found to be 100% for the setup used. All of the reed switches investigated required a substantial drop in ambient magnetic field strength before they deactivated.
Conclusions
MALSE is a simple concept for alerting MRI staff to a ferromagnetic object being brought into fringe magnetic fields which exceeds MALSEs activation magnetic field. MALSE can easily be attached to ferromagnetic objects within the vicinity of a scanner, thus creating a barrier for hazardous situations induced by ferromagnetic parts which should not enter the vicinity of an MR-system to occur.
A novel method to determine the extruded length of a metallic wire for a directed energy deposition (DED) process using a microwave (MW) plasma jet with a straight-through wire feed is presented. The method is based on the relative comparison of the measured frequency response obtained by the large-signal scattering parameter (Hot-S) technique. In the practical working range, repeatability of less than 6% for a nonactive plasma and 9% for the active plasma state is found. Measurements are conducted with a focus on a simple solution to decrease the processing time and reduce the integration time of the process into the existing hardware. It is shown that monitoring a single frequency for magnitude and phase changes is sufficient to achieve good accuracy. A combination of different measurement values to determine the length is possible. The applicability to different diameter of the same material is shown as well as a contact detection of the wire and metallic substrate.
Purpose:
To investigate the feasibility of using magnetohydrodynamic (MHD) effects for synchronization of magnetic resonance imaging (MRI) with the cardiac cycle.
Materials and Methods:
The MHD effect was scrutinized using a pulsatile flow phantom at B0 = 7.0 T. MHD effects were examined in vivo in healthy volunteers (n = 10) for B0 ranging from 0.05–7.0 T. Noncontrast-enhanced MR angiography (MRA) of the carotids was performed using a gated steady-state free-precession (SSFP) imaging technique in conjunction with electrocardiogram (ECG) and MHD synchronization.
Results:
The MHD potential correlates with flow velocities derived from phase contrast MRI. MHD voltages depend on the orientation between B0 and the flow of a conductive fluid. An increase in the interelectrode spacing along the flow increases the MHD potential. In vivo measurement of the MHD effect provides peak voltages of 1.5 mV for surface areas close to the common carotid artery at B0 = 7.0 T. Synchronization of MRI with the cardiac cycle using MHD triggering is feasible. MHD triggered MRA of the carotids at 3.0 T showed an overall image quality and richness of anatomic detail, which is comparable to ECG-triggered MRAs.
Conclusion:
This feasibility study demonstrates the use of MHD effects for synchronization of MR acquisitions with the cardiac cycle. J. Magn. Reson. Imaging 2012;36:364–372. © 2012 Wiley Periodicals, Inc.
Design of a Measurement Setup for the Impedance of Low-Resistance Plate-Conductors in the RF-Range
(2006)
Purpose
To design and evaluate a four-channel cardiac transceiver coil array for functional cardiac imaging at 7T.
Materials and Methods
A four-element cardiac transceiver surface coil array was developed with two rectangular loops mounted on an anterior former and two rectangular loops on a posterior former. specific absorption rate (SAR) simulations were performed and a Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-1 calibration method was applied prior to obtain 2D FLASH CINE (mSENSE, R = 2) images from nine healthy volunteers with a spatial resolution of up to 1 × 1 × 2.5 mm3.
Results
Tuning and matching was found to be better than 10 dB for all subjects. The decoupling (S21) was measured to be >18 dB between neighboring loops, >20 dB for opposite loops, and >30 dB for other loop combinations. SAR values were well within the limits provided by the IEC. Imaging provided clinically acceptable signal homogeneity with an excellent blood-myocardium contrast applying the Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-2 calibration approach.
Conclusion
A four-channel cardiac transceiver coil array for 7T was built, allowing for cardiac imaging with clinically acceptable signal homogeneity and an excellent blood-myocardium contrast. Minor anatomic structures, such as pericardium, mitral, and tricuspid valves and their apparatus, as well as trabeculae, were accurately delineated.