Solar-Institut Jülich
Refine
Year of publication
Institute
- Solar-Institut Jülich (107)
- Fachbereich Bauingenieurwesen (10)
- Fachbereich Energietechnik (10)
- ECSM European Center for Sustainable Mobility (1)
- Fachbereich Chemie und Biotechnologie (1)
- IBB - Institut für Baustoffe und Baukonstruktionen (1)
- Institut fuer Angewandte Polymerchemie (1)
- Kommission für Forschung und Entwicklung (1)
Document Type
- Article (107) (remove)
Keywords
- Haustechnik (2)
- Heizung (2)
- Klimatechnik (2)
- Lüftung (2)
- Lüftungstechnik (2)
- Abluft (1)
- Dynamic simulation (1)
- Mischen (1)
- Modelica (1)
- Molten salt receiver system (1)
- Molten salt solar tower (1)
- Nasskühlturm (1)
- Transient flux distribution (1)
- Trockenkühlturm (1)
- Two-phase modelling (1)
- borefields (1)
- building energy modelling (1)
- building energy simulation (1)
- concentrating collector (1)
- energy (1)
- geothermal (1)
- heat demand (1)
- heat transfer coefficient (1)
- kombiniertes Verfahren (1)
- point-focussing system (1)
- raytracing (1)
- sizing (1)
- solar process heat (1)
Speicher statt Kohle. Integration thermischer Stromspeicher in vorhandene Kraftwerksstandorte
(2019)
The optical performance of a 2-axis solar concentrator was simulated with the COMSOL Multiphysics® software. The concentrator consists of a mirror array, which was created using the application builder. The mirror facets are preconfigured to form a focal point. During tracking all mirrors are moved simultaneously in a coupled mode by 2 motors in two axes, in order to keep the system in focus with the moving sun. Optical errors on each reflecting surface were implemented in combination with the solar angular cone of ± 4.65 mrad. As a result, the intercept factor of solar radiation that is available to the receiver was calculated as a function of the transversal and longitudinal angles of incidence. In addition, the intensity distribution on the receiver plane was calculated as a function of the incidence angles.
In this paper the results of a techno-economic analysis of improved and optimized molten salt solar tower plants (MSSTP plants) are presented. The potential improvements that were analyzed include different receiver designs, different designs of the HTF-system and plant control, increased molten salt temperatures (up to 640°C) and multi-tower systems. Detailed technological and economic models of the solar field, solar receiver and high temperature fluid system (HTF-system) were developed and used to find potential improvements compared to a reference plant based on Solar Two technology and up-to-date cost estimations. The annual yield model calculates the annual outputs and the LCOE of all variants. An improved external tubular receiver and improved HTF-system achieves a significant decrease of LCOE compared to the reference. This is caused by lower receiver cost as well as improvements of the HTF-system and plant operation strategy, significantly reducing the plant own consumption. A novel star receiver shows potential for further cost decrease. The cavity receiver concepts result in higher LCOE due to their high investment cost, despite achieving higher efficiencies. Increased molten salt temperatures seem possible with an adapted, closed loop HTF-system and achieve comparable results to the original improved system (with 565°C) under the given boundary conditions. In this analysis all multi tower systems show lower economic viability compared to single tower systems, caused by high additional cost for piping connections and higher cost of the receivers.
REFERENCES
Optimisation of a urea selective catalytic reduction system with a coated ceramic mixing element
(2017)
Simulation model for the transient process behaviour of solar aluminium recycling in a rotary kiln
(2015)
This paper describes the modeling of a high-temperature storage system for an existing solar tower power plant with open volumetric receiver technology, which uses air as heat transfer medium (HTF). The storage system model has been developed in the simulation environment Matlab/Simulink®. The storage type under investigation is a packed bed thermal energy storage system which has the characteristics of a regenerator. Thermal energy can be stored and discharged as required via the HTF air. The air mass flow distribution is controlled by valves, and the mass flow by two blowers. The thermal storage operation strategy has a direct and significant impact on the energetic and economic efficiency of the solar tower power plants.