Elsevier
Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (181)
- INB - Institut für Nano- und Biotechnologien (105)
- IfB - Institut für Bioengineering (63)
- Fachbereich Chemie und Biotechnologie (58)
- Fachbereich Luft- und Raumfahrttechnik (33)
- Fachbereich Energietechnik (29)
- Fachbereich Maschinenbau und Mechatronik (16)
- Fachbereich Bauingenieurwesen (14)
- Solar-Institut Jülich (14)
- Fachbereich Elektrotechnik und Informationstechnik (9)
Language
- English (347) (remove)
Document Type
- Article (326)
- Part of a Book (11)
- Conference Proceeding (9)
- Other (1)
Keywords
- Earthquake (4)
- LAPS (4)
- Gamification (3)
- Heparin (3)
- Central receiver power plant (2)
- Central receiver system (2)
- Chemometrics (2)
- Concentrated solar collector (2)
- Concentrated systems (2)
- Field-effect sensor (2)
- Gas turbine (2)
- IR spectroscopy (2)
- Light-addressable potentiometric sensor (2)
- NMR spectroscopy (2)
- Solar concentration (2)
- Standardization (2)
- hydrogen peroxide (2)
- qNMR (2)
- (Bio)degradation (1)
- (Poly)saccharides (1)
- Adaptive Systems (1)
- Adaptive control (1)
- Additive Manufacturing (1)
- Additive manufacturing (1)
- Alginate beads (1)
- Aloe vera (1)
- Alzheimer's disease (1)
- Anastomotic leakage (1)
- Assembly (1)
- Assistive technology (1)
- Asymptotic efficiency (1)
- Augmented Reality (1)
- Authenticity (1)
- Autolysis (1)
- Automatic control (1)
- Avalanche (1)
- Bacillus atrophaeus (1)
- Binder Jetting (1)
- Biocomposites (1)
- Biomass (1)
- Bootstrapping (1)
- Borehole heat exchanger (1)
- CNOT (1)
- Calorimetric gas sensor (1)
- Capacitive field-effect (1)
- Cardiac tissue (1)
- Carrier solvents (1)
- Cell permeability (1)
- CellDrum (1)
- Cellular force (1)
- Censored data (1)
- Chemical images (1)
- Chemical imaging sensor (1)
- Chemical sensor (1)
- Chimeric liver-humanized mice (1)
- Collective risk model (1)
- Competitiveness (1)
- Computational biomechanics (1)
- Concentrating solar power (1)
- Constitutive model (1)
- Contractile tension (1)
- Cross border adjustment mechanism (1)
- Crude heparin (1)
- C–V method (1)
- DLR-ESTEC GOSSAMER roadmap for solar sailing (1)
- DNA biosensor (1)
- DNA hybridization (1)
- Damage mechanics theory (1)
- Decomposition (1)
- Decoupling (1)
- Dehydrogenase (1)
- Detergent protease (1)
- Deuterated solvents (1)
- Deuterium NMR (1)
- Diaphorase (1)
- Digital Twin (1)
- Dimensional splitting (1)
- Directed Energy Deposition (1)
- Discontinuous fractures (1)
- Drinfeld modules (1)
- Drug distribution (1)
- Drug metabolism (1)
- Drug simulation (1)
- Dry-low-NOx (DLN) combustion (1)
- Dynamic simulation (1)
- E-Mobility (1)
- E. coli detection (1)
- EGG (1)
- EIS capacitive sensor (1)
- Electrolyte–insulator–semiconductor (1)
- Electromechanical modeling (1)
- Electronic cigarettes (1)
- End-to-end colorectal anastomosis (1)
- Endothelial cells (1)
- Energy-intensive industry (1)
- Enzymatic biosensor (1)
- Enzyme logic gate (1)
- Error Recovery (1)
- Exponential time differencing (1)
- External knee adduction moments (1)
- Extracellular enzymes (1)
- Fault detection (1)
- Field effect (1)
- Finite differences (1)
- Finite element analysis (1)
- Finite element modelling (1)
- Floor prices (1)
- Fracture classification (1)
- Frame structure (1)
- Free-base nicotine (1)
- Freeze–thaw process (1)
- Frequency adaption (1)
- Fresnel collector (1)
- Fresnel power plant (1)
- Fuel cell (1)
- GOSSAMER-1 (1)
- Gamma distribution (1)
- Goodness-of-fit test (1)
- Hazard assessment (1)
- Health management system (1)
- Heat transport (1)
- High hydrogen combustion (1)
- Higher derivations (1)
- Hodgkin–Huxley models (1)
- Homogenization (1)
- Human-Computer interaction (1)
- Humidity (1)
- Hybridization (1)
- Hydrogen combustion (1)
- Hydrogen gas turbine (1)
- Hydrogen peroxide (1)
- Hypersecretion (1)
- INSYSME (1)
- Imaging (1)
- Impedance spectroscopy (1)
- In-plane performance, isolation (1)
- Independence test (1)
- Infill wall design (1)
- Inorganic ions (1)
- Interplanetary flight (1)
- Interstellar objects (1)
- Inverse dynamic problem (1)
- Inverse kinematic problem (1)
- Ions (1)
- Iterative learning control (1)
- Knockout mice (1)
- L-PBF (1)
- LPBF (1)
- Label-free detection (1)
- Landslide tsunamis (1)
- Large scale tests (1)
- Larynx position (1)
- Laser-Powder Bed Fusion (1)
- Layer-by-layer adsorption (1)
- Level system (1)
- Light-addressable Potentiometric Sensor (1)
- Lipopolysaccharide (1)
- Liver (1)
- Low field NMR (1)
- Low-field NMR (1)
- Manipulated variables (1)
- Marker-free mutagenesis (1)
- Masonry infill (1)
- Masonry partition walls (1)
- Master stamp (1)
- Matrix exponential (1)
- Micromix combustion (1)
- Mild cognitive impairment (1)
- Missions (1)
- Mobility transition (1)
- Molecular modelling (1)
- Molecular weight determination (1)
- Molten salt receiver system (1)
- Molten salt solar tower (1)
- Morphing (1)
- Multi-criteria decision analysis (1)
- Multi-storey (1)
- Musculoskeletal model (1)
- NMR (1)
- NMR exchange relaxometry (1)
- Natural fibres (1)
- Negative impedance convertor (1)
- Niacin (1)
- Non-model-based Evaluation (1)
- Non-parallel fissures (1)
- Numerical modelling (1)
- Online diagnostic (1)
- Optical and thermal analysis (1)
- Organic acids (1)
- Organic light-emitting diode display (1)
- Out-of-plane capacity (1)
- Overland flow (1)
- PLS-regression (1)
- Parametric bootstrap (1)
- Periods (1)
- Photolithographic mimics (1)
- Piping (1)
- Poly(allylamine hydrochloride) (1)
- Poly(d,l-lacticacid) (1)
- Polyimide (1)
- Polymer-matrix composites (1)
- Powder Material (1)
- Power conversion systems (1)
- Preference assessment (1)
- Principal component analysis (1)
- Probability distribution mapping (1)
- Product-integration (1)
- Proper Orthogonal Decomposition (1)
- Pulsations (1)
- Q-criterion (1)
- Quality control (1)
- Quantum chemistry (1)
- Quartz crystal microbalance (1)
- Reaction-diffusion systems (1)
- Real distinct pole (1)
- Real-time monitoring (1)
- Recombinant activated protein C (1)
- Regionalization (1)
- Rehabilitation engineering (1)
- Reinforced concrete frame (1)
- Resonance-mode measurement (1)
- Retinal vessel analysis (1)
- Riboflavin (1)
- Robotic rehabilitation (1)
- Seismic loading (1)
- Semi-parametric random censorship model (1)
- Shoulder (1)
- Simultaneous determination (1)
- Slab deflection (1)
- Small spacecraft (1)
- Snow (1)
- Soft independent modeling of class analogy (1)
- Solar dish (1)
- Solar sail (1)
- Solitary waves (1)
- Spacecraft (1)
- Spectroscopy (1)
- Spleen (1)
- Steel industry (1)
- Stenotrophomonas maltophilia (1)
- Sterilisation process (1)
- Stress concentrations (1)
- Support System (1)
- Surface imprinted polymer (1)
- Surgical staplers (1)
- Survival analysis (1)
- Tank (1)
- Thiamine (1)
- Tomography (1)
- Toxicology (1)
- Trajectories (1)
- Transcendence (1)
- Transfer impedance (1)
- Transient flux distribution (1)
- Two-phase modelling (1)
- USP (1)
- Uniaxial compression test (1)
- Uracil-phosphoribosyltransferase (1)
- User study (1)
- Vapnik–Čhervonenkis class (1)
- Variable height stapler design (1)
- Vasomotions (1)
- Virtual reality (1)
- Vitamin A (1)
- Vitamin B (1)
- Voice assessment (1)
- Volterra integral equation (1)
- Weak organic acids (1)
- XOR (1)
- anaesthetic complications (1)
- barium strontium titanate (1)
- calorimetric gas sensor (1)
- coherent structures (1)
- constructive alignment (1)
- contactless conductivity sensor (1)
- dental trauma (1)
- difficult airway (1)
- double-lumen tube intubation (1)
- enzymatic (bio)degradation (1)
- examination (1)
- field-effect sensor (1)
- hiPS cardiomyocytes (1)
- high-k material (1)
- hydraulic modelling (1)
- impedance spectroscopy (1)
- in-situ monitoring (1)
- intraclass correlation coefficient (1)
- lable-free detection (1)
- long-term retention (1)
- magnetic actuation (1)
- magnetic separation (1)
- magnetic tweezers (1)
- magnetophoretic velocity (1)
- model performance (1)
- multi-functional material (1)
- multimodal (1)
- novel photoexcitation method (1)
- poly(d, l-lactic acid) (1)
- practical learning (1)
- shoulder (1)
- spatial resolution (1)
- standard error of measurement (1)
- sterilisation (1)
- stretch reflex (1)
- superparamagnetic bead (1)
- t-modules (1)
- test-retest reliability (1)
- tilted constant illumination (1)
- videolaryngoscopy (1)
A variety of transition metals, e.g., copper, zinc, cadmium, lead, etc. are widely used in industry as components for wires, coatings, alloys, batteries, paints and so on. The inevitable presence of transition metals in industrial processes implies the ambition of developing a proper analytical technique for their adequate monitoring. Most of these elements, especially lead and cadmium, are acutely toxic for biological organisms. Quantitative determination of these metals at low activity levels in different environmental and industrial samples is therefore a vital task. A promising approach to achieve an at-side or on-line monitoring on a miniaturized and cost efficient way is the combination of a common potentiometric sensor array with heavy metal-sensitive thin-film materials, like chalcogenide glasses and polymeric materials, respectively.
Real-time and reliable monitoring of the biogas process is crucial for a stable and efficient operation of biogas production in order to avoid digester breakdowns. The concentration of dissolved hydrogen (H₂) represents one of the key parameters for biogas process control. In this work, a one-chip integrated combined amperometric/field-effect sensor for monitoring the dissolved H₂ concentration has been developed for biogas applications. The combination of two different transducer principles might allow a more accurate and reliable measurement of dissolved H₂ as an early warning indicator of digester failures. The feasibility of the approach has been demonstrated by simultaneous amperometric/field-effect measurements of dissolved H₂ concentrations in electrolyte solutions. Both, the amperometric and the field-effect transducer show a linear response behaviour in the H₂ concentration range from 0.1 to 3% (v/v) with a slope of 198.4 ± 13.7 nA/% (v/v) and 14.9 ± 0.5 mV/% (v/v), respectively.
Using a cell-based gas biosensor for investigation of adverse effects of acetone vapors in vitro
(2013)
In vitro studies of the degradation kinetic of biopolymers are essential for the design and optimization of implantable biomedical devices. In the presented work, a field-effect capacitive sensor has been applied for the real-time and in situ monitoring of degradation processes of biopolymers for the first time. The polymer-covered field-effect sensor is, in principle, capable to detect any changes in bulk, surface and interface properties of the polymer induced by degradation processes. The feasibility of this approach has been experimentally proven by using the commercially available biomedical polymer poly(D,L-lactic acid) (PDLLA) as a model system. PDLLA films of different thicknesses were deposited on the Ta₂O₅-gate surface of the field-effect structure from a polymer solution by means of spin-coating method. The polymer-modified field-effect sensors have been characterized by means of capacitance–voltage and impedance-spectroscopy method. The degradation of the PDLLA was accelerated by changing the degradation medium from neutral (pH 7.2) to alkaline (pH 9) condition, resulting in drastic changes in the capacitance and impedance spectra of the polymer-modified field-effect sensor.
Realisation of a calorimetric gas sensor on polyimide foil for applications in aseptic food industry
(2012)
A calorimetric gas sensor is presented for the monitoring of vapour-phase H2O2 at elevated temperature during sterilisation processes in aseptic food industry. The sensor was built up on a flexible polyimide foil (thickness: 25 μm) that has been chosen due to its thermal stability and low thermal conductivity. The sensor set-up consists of two temperature-sensitive platinum thin-film resistances passivated by a layer of SU-8 photo resist and catalytically activated by manganese(IV) oxide. Instead of an active heating structure, the calorimetric sensor utilises the elevated temperature of the evaporated H2O2 aerosol. In an experimental test rig, the sensor has shown a sensitivity of 4.78 °C/(%, v/v) in a H2O2 concentration range of 0%, v/v to 8%, v/v. Furthermore, the sensor possesses the same, unchanged sensor signal even at varied medium temperatures between 210 °C and 270 °C of the gas stream. At flow rates of the gas stream from 8 m3/h to 12 m3/h, the sensor has shown only a slightly reduced sensitivity at a low flow rate of 8 m3/h. The sensor characterisation demonstrates the suitability of the calorimetric gas sensor for monitoring the efficiency of industrial sterilisation processes.
The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the two-dimensional distribution of specific ions or molecules in the solution. In this study, we developed a miniaturized chemical imaging sensor system with an OLED display panel as a light source that scans the sensor plate. In the proposed configuration, the display panel is placed directly below the sensor plate and illuminates the back surface. The measured area defined by illumination can be arbitrarily customized to fit the size and the shape of the sample to be measured. The waveform of the generated photocurrent, the current–voltage characteristics and the pH sensitivity were investigated and pH imaging with this miniaturized system was demonstrated.
Patients after coarctation repair still have an increased risk of cardiovascular or cerebrovascular events. This has been explained by the persisting hypertension and alterations in the peripheral vessels. However, involvement of the central vessels such as the retinal arteries is virtually unknown. A total of 34 patients after coarctation repair (22 men and 12 women; 23 to 58 years old, age range 0 to 32 years at surgical repair) and 34 nonhypertensive controls underwent structural and functional retinal vessel analysis. Using structural analysis, the vessel diameters were measured. Using functional analysis, the endothelium-dependent vessel dilation in response to flicker light stimulation was assessed. In the patients after coarctation repair, the retinal arteriolar diameter was significantly reduced compared to that of the controls (median 182 μm, first to third quartile 171 to 197; vs 197 μm, first to third quartile 193 to 206; p <0.001). These findings were independent of the peripheral blood pressure and age at intervention. No differences were found for venules. The functional analysis findings were not different between the patients and controls (maximum dilation 3.5%, first to third quartile 2.1% to 4.5% vs 3.6%, first to third quartile 2.2% to 4.3%; p = 0.81), indicating preserved autoregulative mechanisms. In conclusion, the retinal artery diameter is reduced in patients after coarctation repair, independent of their current blood pressure level and age at intervention. As a structural marker of chronic vessel damage associated with past, current, or future hypertension, retinal arteriolar narrowing has been linked to stroke incidence. These results indicate an involvement of cerebral microcirculation in aortic coarctation, despite timely repair, and might contribute to explain the increased rate of cerebrovascular events in such patients.
The impact of surgical staplers on tissues has been studied mostly in an empirical manner. In this paper, finite element method was used to clarify the mechanics of tissue stapling and associated phenomena. Various stapling modalities and several designs of circular staplers were investigated to evaluate the impact of the device on tissues and mechanical performance of the end-to-end colorectal anastomosis. Numerical simulations demonstrated that a single row of staples is not adequate to resist leakage due to non-linear buckling and opening of the tissue layers between two adjacent staples. Compared to the single staple row configuration, significant increase in stress experienced by the tissue at the inner staple rows was observed in two and three rows designs. On the other hand, adding second and/or third staple row had no effect on strain in the tissue inside the staples. Variable height design with higher staples in outer rows significantly reduced the stresses and strains in outer rows when compared to the same configuration with flat cartridge.
Influence of a freeze–thaw cycle on the stress–stretch curves of tissues of porcine abdominal organs
(2012)
The paper investigates both fresh porcine spleen and liver and the possible decomposition of these organs under a freeze–thaw cycle. The effect of tissue preservation condition is an important factor which should be taken into account for protracted biomechanical tests. In this work, tension tests were conducted for a large number of tissue specimens from twenty pigs divided into two groups of 10. Concretely, the first group was tested in fresh state; the other one was tested after a freeze-thaw cycle which simulates the conservation conditions before biomechanical experiments. A modified Fung model for isotropic behavior was adopted for the curve fitting of each kind of tissues. Experimental results show strong effects of the realistic freeze–thaw cycle on the capsule of elastin-rich spleen but negligible effects on the liver which virtually contains no elastin. This different behavior could be explained by the autolysis of elastin by elastolytic enzymes during the warmer period after thawing. Realistic biomechanical properties of elastin-rich organs can only be expected if really fresh tissue is tested. The observations are supported by tests of intestines.