Wiley-VCH
Refine
Year of publication
Institute
- Fachbereich Chemie und Biotechnologie (78)
- Fachbereich Medizintechnik und Technomathematik (52)
- INB - Institut für Nano- und Biotechnologien (49)
- Fachbereich Elektrotechnik und Informationstechnik (6)
- Fachbereich Energietechnik (3)
- Fachbereich Maschinenbau und Mechatronik (3)
- IfB - Institut für Bioengineering (3)
- Institut fuer Angewandte Polymerchemie (3)
- Nowum-Energy (3)
- Arbeitsstelle fuer Hochschuldidaktik und Studienberatung (1)
Document Type
- Article (83)
- Conference: Meeting Abstract (49)
- Part of a Book (8)
- Review (1)
Keywords
- biosensors (3)
- capacitive field-effect sensors (2)
- Adsorbentien (1)
- Adsorption (1)
- Bacillus atrophaeus (1)
- Bioabsorbable (1)
- Biofuel (1)
- Biorefinery (1)
- Butanol (1)
- CRISPR/Cas9 (1)
Ground or aerial robots equipped with advanced sensing technologies, such as three-dimensional laser scanners and advanced mapping algorithms, are deemed useful as a supporting technology for first responders. A great deal of excellent research in the field exists, but practical applications at real disaster sites are scarce. Many projects concentrate on equipping robots with advanced capabilities, such as autonomous exploration or object manipulation. In spite of this, realistic application areas for such robots are limited to teleoperated reconnaissance or search. In this paper, we investigate how well state-of-the-art and off-the-shelf components and algorithms are suited for reconnaissance in current disaster-relief scenarios. The basic idea is to make use of some of the most common sensors and deploy some widely used algorithms in a disaster situation, and to evaluate how well the components work for these scenarios. We acquired the sensor data from two field experiments, one from a disaster-relief operation in a motorway tunnel, and one from a mapping experiment in a partly closed down motorway tunnel. Based on these data, which we make publicly available, we evaluate state-of-the-art and off-the-shelf mapping approaches. In our analysis, we integrate opinions and replies from first responders as well as from some algorithm developers on the usefulness of the data and the limitations of the deployed approaches, respectively. We discuss the lessons we learned during the two missions. These lessons are interesting for the community working in similar areas of urban search and rescue, particularly reconnaissance and search.
Detection of triacetone triperoxide using temperature cycled metal-oxide semiconductor gas sensors
(2015)
Die Detektion von Schadstoffen repräsentiert in der Umweltanalytik eine wichtige Aufgabenstellung. Gerade die Abwasser- bzw. Brauchwasseranalytik sowie die Prozesskontrolle haben einen hohen Stellenwert. Siliziumbasierte Dünnschichtsensoren bieten eine kostengünstige Möglichkeit, „online“-Messungen bzw. Vor-Ort-Messungen zeitnah durchzuführen. In dieser Arbeit wird ein potentiometrisches Sensorarray auf der Basis von Chalkogenidgläsern zur Detektion von Schwermetallen in wässrigen Medien vorgestellt.
Engineering of functional interfaces / Patrick Wagner ; Theodor Doll ; Michael J. Schöning (eds.)
(2014)
Among the variety of transducer concepts proposed for label-free detection of biomolecules, the semiconductor field-effect device (FED) is one of the most attractive platforms. As medical techniques continue to progress towards diagnostic and therapies based on biomarkers, the ability of FEDs for a label-free, fast and real-time detection of multiple pathogenic and physiologically relevant molecules with high specificity and sensitivity offers very promising prospects for their application in point-of-care and personalized medicine for an early diagnosis and treatment of diseases. The presented paper reviews recent advances and current trends in research and development of different FEDs for label-free, direct electrical detection of charged biomolecules by their intrinsic molecular charge. The authors are mainly focusing on the detection of the DNA hybridization event, antibody-antigen affinity reaction as well as clinically relevant biomolecules such as cardiac and cancer biomarkers.
A multi-spot (4 × 4 spots) light-addressable potentiometric sensor (MLAPS) consisting of an Al–p-Si–SiO2 structure has been applied for the label-free electrical detection of DNA (deoxyribonucleic acid) immobilization and hybridization by the intrinsic molecular charge for the first time. Single-stranded probe ssDNA molecules (20 bases) were covalently immobilized onto the silanized SiO2 gate surface. The unspecific adsorption of mismatch ssDNA on the MLAPS gate surface was blocked by bovine serum albumin molecules. To reduce the screening effect and to achieve a high sensor signal, the measurements were performed in a low ionic-strength solution. The photocurrent–voltage (I–V) curves were simultaneously recorded on all 16 spots after each surface functionalization step. Large shifts of I–V curves of 25 mV were registered after the DNA immobilization and hybridization event. In contrast, a small potential shift (∼5 mV) was observed in case of mismatch ssDNA, revealing good specificity of the sensor. The obtained results demonstrate the potential of the MLAPS as promising transducer platform for the multi-spot label-free electrical detection of DNA molecules by their intrinsic molecular charge.
The metabolic activity of Chinese hamster ovary (CHO) cells was observed using a light-addressable potentiometric sensor (LAPS). The dependency toward different glucose concentrations (17–200 mM) follows a Michaelis–Menten kinetics trajectory with Kₘ = 32.8 mM, and the obtained Kₘ value in this experiment was compared with that found in literature. In addition, the pH shift induced by glucose metabolism of tumor cells transfected with the HPV-16 genome (C3 cells) was successfully observed. These results indicate the possibility to determine the tumor cells metabolism with a LAPS-based measurement device.
The light-addressable potentiometric sensor (LAPS) is a semiconductor-based potentiometric sensor using a light probe with an ability of detecting the concentration of biochemical species in a spatially resolved manner. As an important biomedical sensor, research has been conducted to improve its performance, for instance, to realize high-speed measurement. In this work, the idea of facilitating the device-level simulation, instead of using an equivalent-circuit model, is presented for detailed analysis and optimization of the performance of the LAPS. Both carrier distribution and photocurrent response have been simulated to provide new insight into both amplitude-mode and phase-mode operations of the LAPS. Various device parameters can be examined to effectively design and optimize the LAPS structures and setups for enhanced performance.
Planar and three-dimensional (3D) interdigitated electrodes (IDE) with electrode digits separated by an insulating barrier of different heights were electrochemically characterized and compared in terms of their sensing properties. Due to the impact of the surface resistance, both types of IDE structures display a non-linear behavior in low-ionic strength solutions. The experimental data were fitted to an electrical equivalent circuit and interpreted taking into account the surface-charge-governed properties. The effect of a charged polyelectrolyte layer electrostatically assembled onto the sensor surface on the surface resistance in solutions with different KCl concentration is studied. In case of the same electrode footprint, 3D-IDEs show a larger cell constant and a higher sensitivity to molecular adsorption than that of planar IDEs. The obtained results demonstrate the potential of 3D-IDEs as a new transducer structure for a direct label-free sensing of charged molecules.
It is well known that biochemical and biotechnological processes are strongly dependent and affected by a variety of physico-chemical parameters such as pH value, temperature, pressure and electrolyte conductivity. Therefore, these quantities have to be monitored or controlled in order to guarantee a stable process operation, optimization and high yield. In this work, a sensor chip for the multiparameter detection of three physico-chemical parameters such as electrolyte conductivity, pH and temperature is realized using barium strontium titanate (BST) as multipurpose material. The chip integrates a capacitively coupled four-electrode electrolyte-conductivity sensor, a capacitive field-effect pH sensor and a thin-film Pt-temperature sensor. Due to the multifunctional properties of BST, it is utilized as final outermost coating layer of the processed sensor chip and serves as passivation and protection layer as well as pH-sensitive transducer material at the same time. The results of testing of the individual sensors of the developed multiparameter sensor chip are presented. In addition, a quasi-simultaneous multiparameter characterization of the sensor chip in buffer solutions with different pH value and electrolyte conductivity is performed. To study the sensor behavior and the suitability of BST as multifunctional material under harsh environmental conditions, the sensor chip was exemplarily tested in a biogas digestate.
In this work, the catalyst manganese(IV) oxide (MnO2), of calorimetric gas sensors (to monitor the sterilization agent vaporized hydrogen peroxide) has been investigated in more detail. Chemical analyses by means of X-ray-induced photoelectron spectroscopy have been performed to unravel the surface chemistry prior and after exposure to hydrogen peroxide vapor at elevated temperature, as applied in the sterilization processes of beverage cartons. The surface characterization reveals a change in oxidation states of the metal oxide catalyst after exposure to hydrogen peroxide. Additionally, a cleaning effect of the catalyst, which itself is attached to the sensor surface by means of a polymer interlayer, could be observed.
It is well known that the degradation environment can strongly influence the biodegradability and kinetics of biodegradation processes of polymers. Therefore, besides the monitoring of the degradation process, it is also necessary to control the medium in which the degradation takes place. In this work, a micromachined multi-parameter sensor chip for the control of the polymer-degradation medium has been developed. The chip combines a capacitive field-effect pH sensor, a four-electrode electrolyte-conductivity sensor and a thin-film Pt-temperature sensor. The results of characterization of individual sensors are presented. In addition, the multi-parameter sensor chip together with an impedimetric polymer-degradation sensor was simultaneously characterized in degradation solutions with different pH and electrolyte conductivity. The obtained results demonstrate the feasibility of the multi-parameter sensor chip for the control of the polymer-degradation medium.
Die tert.-Butyloxycarbonyl-Gruppe (Boc) läßt sich mittels reiner Trifluoressigsäure nicht selektiv neben dem Benzyloxycarbonyl-Rest (Z) abspalten. Das gelingt auch nicht mit Lösungen von Trifluoressigsäure bzw. Chlorwasserstoff in organischen Lösungsmitteln. Kern-substituierte Z-Gruppen wie Z(pCl), Z(mCl) oder Z(pNO₂) sind zwar stabiler, werden aber von den obengenannten Reagenzien ebenfalls angegriffen bzw. sind nicht mehr acidolytisch abspaltbar. – Mit 70proz. wäßriger Trifluoressigsäure gelingt die Abspaltung von Boc neben Z dagegen fast selektiv; dabei werden aber Benzylester, besonders Glutaminsäure-γ-benzylester, teilweise hydrolysiert, während Methyl- sowie Äthylester nahezu beständig sind. Die Brauchbarkeit des Abspaltungsverfahrens wird anhand der schrittweise durchgeführten Synthese zweier Heptapeptid-Derivate gezeigt. – Ähnlich spezifisch gelingt die Abspaltung von Boc mit Bortrifluorid-ätherat in Eisessig; Benzylester sind gegenüber diesem Reagenz stabiler als gegen wäßrige Trifluoressigsäure. Das Bortrifluorid-Verfahren eignet sich besonders für die Abspaltung von Boc-Gruppen neben säurelabilen Thiol-Schutzgruppen (Tetrahydropyranyl- bzw. Trityl-Rest) sowie neben dem Cyclocystinyl-Rest. Die Leistungsfähigkeit der Methode wird durch die Synthese zweier Peptid-Derivate mit S-Trityl-Schutzgruppen belegt. Als Nebenreaktion ist die Acetylierung von aliphatischen Hydroxylgruppen möglich. Sie läßt sich vermeiden, wenn man die Spaltung in anderen Lösungsmitteln durchführt. Die als Modellverbindungen für Stabilitätsuntersuchungen verwendeten Nε-acylierten Lysin-Derivate werden mit dem Aminosäureanalysator quantitativ neben Lysin bestimmt.
Es wird die Synthese der Sequenz A 6–9 des Schafinsulins in der geschützten Form Boc-Cys-Cys-Ala-Gly-OBuᵗ (5) sowie das Verhalten dieses monomeren cyclischen Cystinpeptidderivates gegenüber den in der Peptidchemie gebräuchlichen Reagenzien Bortrifluorid/Eisessig, Triäthylamin und Hydrazinhydrat beschrieben.
Die Darstellung der N-[2-(p-Biphenylyl)isopropyloxycarbonyl]-Derivate (Bpoc-Derivate) des Cysteins unter Verwendung der Thiolschutzgruppen Tetrahydropyranyl (Thp) für 1, Diphenylmethyl (Dpm) für 2, Trityl (Trt) für 3 und S-tert.-Butyl (SBut) für 4 sowie die Synthese von aktivierten Estern der Bpoc-Derivate des Glycins (5), Isoleucins (6) und Prolins (7) werden beschrieben. An einem Beispiel wird die Möglichkeit aufgezeigt, die Bpoc-Gruppe über das Bpoc-Azid nachträglich in den Peptidverband einzuführen.
Die Synthese der Sequenzen A2—21 (13) und A1—21 (15) der Schafinsulin-A-Kette als monomere cyclische Dicystinpeptidderivate wird beschrieben. Die intrachenaren Cystinbrücken A6—7 und A 11 —20 vermitteln die Löslichkeit dieser Derivate in Dimethylformamid und ermöglichen erstmalig die Reindarstellung vollgeschützter Insulin-A-Kettenderivate. Die während der Synthese eingesetzten Schutzgruppen lassen sich mittels Trifluoressigsäure und 2-Mercaptoäthanol quantitativ entfernen.
The objectives of the present work are to characterize the Gas Metal Arc Welding process of DP 600 sheet steel and to summarize the modelling techniques. The time-temperature evolution during the welding cycle was measured experimentally and modelled with the softwaretool SimWeld. To model the phase transformations during the welding cycle dilatometer tests were done to quantify the parameters for phase field modelling by MICRESS®. The important input parameters are interface mobility, nucleation density, etc. A contribution was made to include austenite to bainite transformation in MICRESS®. This is useful to predict the microstructure in the fast cooling segments. The phase transformation model is capable to predict the microstructure along the heating and cooling cycles of welding. Tensile tests have shown the evidence of failure at the heat affected zone, which has the ferrite-tempered martensite microstructure.