Wiley
Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (47)
- INB - Institut für Nano- und Biotechnologien (33)
- Fachbereich Chemie und Biotechnologie (29)
- IfB - Institut für Bioengineering (18)
- Fachbereich Elektrotechnik und Informationstechnik (17)
- Fachbereich Energietechnik (14)
- Fachbereich Bauingenieurwesen (8)
- Fachbereich Luft- und Raumfahrttechnik (3)
- Fachbereich Maschinenbau und Mechatronik (3)
- Fachbereich Wirtschaftswissenschaften (2)
Has Fulltext
- no (118) (remove)
Document Type
- Article (115)
- Part of a Book (1)
- Conference: Meeting Abstract (1)
- Conference Proceeding (1)
Keywords
- Bemessung (1)
- ES-FEM (1)
- Erdbebeneinwirkung (1)
- FS-FEM (1)
- Mauerwerksbauten (1)
- PushoverAnalysen (1)
- S-FEM (1)
- VOP compression (1)
- Verhaltensbeiwerte (1)
- attitude dynamics (1)
Für die Ermittlung der erforderlichen Einspanntiefe von eingespannten Stahlquerschnitten in Betonkonstruktionen existieren verschiedene Bemessungsmodelle. Diese basieren vorwiegend auf Grundlage nationaler Normen wie z. B. DIN 18800 [1] und DIN 1045 [2], die durch die europäische Normung ersetzt wurden. Aus diesem Grund wird in diesem Aufsatz ein Berechnungsmodell für die erforderliche Einspanntiefe von eingespannten Stahlquerschnitten in Betonkonstruktionen auf Grundlage des Eurocodes vorgestellt. Das Grundgerüst für dieses Berechnungsmodell bildet das Verfahren nach Kindmann und Laumann, welches in [3] behandelt wurde. Gleichzeitig werden neue Formeln zur direkten Ermittlung der Mindesteinspanntiefe vorgestellt. Behandelt werden gewalzte I-Profile für einachsige Biegung um die starke Achse (y-y) mit Drucknormalkraft.
Moderne Mauerwerksbauten müssen nach heutigen Anforderungen architektonisch, statisch, energetisch sowie schall- und brandschutztechnisch optimal ausgelegt sein. Aufgrund der Komplexität und engen Verzahnung der einzelnen Anforderungen ist eine integrale Gebäudeplanung zur Erzielung einer qualitativ hochwertigen Bauwerkslösung unbedingt notwendig. Diese erfordert von den Fachplanern vertieftes Spezialwissen in den verschiedenen Bereichen, um insbesondere die Schnittstellen und Bauwerksdetails korrekt zu planen und auszuführen. Der Beitrag stellt die integrale Gebäudeplanung am Beispiel eines Geschossbaus in Ziegelbauweise mit Lösungen für wesentliche Detailpunkte vor
Bei der Ausarbeitung des nationalen Anwendungsdokumentes zur DIN EN 1998-1 waren die in der ENV-Fassung enthaltenen vereinfachten Regeln im Lichte aktueller Forschungsergebnisse zu überprüfen und zu überarbeiten. Die gleiche Aufgabe stellte sich auch für die Neufassung der DIN 4149. In beiden Fällen sind neben konstruktiven Regeln für die Art und Anordnung der zur Gebäudeaussteifung heranzuziehenden Wände im Grundriss Tabellen enthalten, die unter bestimmten Bedingungen den Entfall eines rechnerischen Nachweises der Tragwände im Erdbebenfall ermöglichen. Dies ist für Schwachbebengebiete, wie sie in Deutschland und anderen Ländern Mitteleuropas anzutreffen sind, sinnvoll, um unnötigen Rechenaufwand sowie Probleme mit der Führbarkeit von Nachweisen so weit wie möglich auszuschalten. Im vorliegenden Beitrag werden die Hintergründe der vereinfachten Regeln diskutiert und die Ergebnisse der Anwendung mit verschiedenen Rechenverfahren verglichen und bewertet.
A concept for a new generation of an integrated multi-functional biosensor/actuator system is developed, which is based on biomolecular logic principles. Such a system is expected to be able to detect multiple biochemical input signals simultaneously and in real-time and convert them into electrical output signals with logical operations such as OR, AND, etc. The system can be designed as a closed-loop drug release device triggered by an enzyme logic gate, while the release of the drug induced by the actuator at the required dosage and timing will be controlled by an additional drug sensor. Thus, the system could help to make an accurate and specific diagnosis. The presented concept is exemplarily demonstrated by using an enzyme logic gate based on a glucose/glucose oxidase system, a temperature-responsive hydrogel mimicking the actuator function and an insulin (drug) sensor. In this work, the results of functional testing of individual amperometric glucose and insulin sensors as well as an impedimetric sensor for the detection of the hydrogel swelling/shrinking are presented.
A new microfluidic assembly method for semiconductor-based biosensors using 3D-printing technologies was proposed for a rapid and cost-efficient design of new sensor systems. The microfluidic unit is designed and printed by a 3D-printer in just a few hours and assembled on a light-addressable potentiometric sensor (LAPS) chip using a photo resin. The cell growth curves obtained from culturing cells within microfluidics-based LAPS systems were compared with cell growth curves in cell culture flasks to examine biocompatibility of the 3D-printed chips. Furthermore, an optimal cell culturing within microfluidics-based LAPS chips was achieved by adjusting the fetal calf serum concentrations of the cell culture medium, an important factor for the cell proliferation.
Poly(N-isopropylacrylamide) (PNIPAAm) hydrogel films with incorporated graphene oxide (GO) were developed and tested as light-stimulated actuators. GO dispersions were synthesized via Hummers method and characterized toward their optical properties and photothermal energy conversion. The hydrogels were prepared by means of photopolymerization. In addition, the influence of GO within the hydrogel network on the lower critical solution temperature (LCST) was investigated by differential scanning calorimetry (DSC). The optical absorbance and the response to illumination were determined as a function of GO concentration for thin hydrogel films. A proof of principle for the stimulation with light was performed.
An enzyme-based multi-parameter biosensor is developed for monitoring the concentration of formate, d-lactate, and l-lactate in biological samples. The sensor is based on the specific dehydrogenation by an oxidized β-nicotinamide adenine dinucleotide (NAD+)-dependent dehydrogenase (formate dehydrogenase, d-lactic dehydrogenase, and l-lactic dehydrogenase, respectively) in combination with a diaphorase from Clostridium kluyveri (EC 1.8.1.4). The enzymes are immobilized on a platinum working electrode by cross-linking with glutaraldehyde (GA). The principle of the determination scheme in case of l-lactate is as follows: l-lactic dehydrogenase (l-LDH) converts l-lactate into pyruvate by reaction with NAD+. In the presence of hexacyanoferrate(III), the resulting reduced β-nicotinamide adenine dinucleotide (NADH) is then regenerated enzymatically by diaphorase. The electrochemical detection is based on the current generated by oxidation of hexacyanoferrate(II) at an applied potential of +0.3 V vs. an Ag/AgCl reference electrode. The biosensor will be electrochemically characterized in terms of linear working range and sensitivity. Additionally, the successful practical application of the sensor is demonstrated in an extract from maize silage.
Simulating the electromagnetic‐thermal treatment of thin aluminium layers for adhesion improvement
(2015)
A composite layer material used in packaging industry is made from joining layers of different materials using an adhesive. An important processing step in the production of aluminium-containing composites is the surface treatment and consequent coating of adhesive material on the aluminium surface. To increase adhesion strength between aluminium layer and the adhesive material, the foil is heat treated. For efficient heating, induction heating was considered as state-of-the-art treatment process. Due to the complexity of the heating process and the unpredictable nature of the heating source, the control of the process is not yet optimised. In this work, a finite element analysis of the process was established and various process parameters were studied. The process was simplified and modelled in 3D. The numerical model contains an air domain, an aluminium layer and a copper coil fitted with a magnetic field concentrating material. The effect of changing the speed of the aluminium foil (or rolling speed) was studied with the change of the coil current. Statistical analysis was used for generating a general control equation of coil current with changing rolling speed.
High-k perovskite oxide of barium strontium titanate (BST) represents a very attractive multi-functional transducer material for the development of (bio-)chemical sensors. In this work, a Si-based sensor chip containing Pt interdigitated electrodes covered with a thin BST layer (485 nm) has been developed for multi-parameter chemical sensing. The chip has been applied for the contactless measurement of the electrolyte conductivity, the detection of adsorbed charged macromolecules (positively charged polyelectrolytes of polyethylenimine) and the concentration of hydrogen peroxide (H2O2) vapor. The experimental results of functional testing of individual sensors are presented. The mechanism of the BST sensitivity to charged polyelectrolytes and H2O2 vapor has been proposed and discussed.