Taylor & Francis
Refine
Year of publication
- 2016 (3) (remove)
Institute
Has Fulltext
- no (3)
Language
- English (3)
Document Type
- Article (2)
- Conference Proceeding (1)
Is part of the Bibliography
- no (3)
This paper describes the procedure on the evaluation of the masonry chapter for the next generation of Eurocode 8, the European Standard for earthquake-resistant design. In CEN, TC 250/SC8, working group WG 1 has been established to support the subcommittee on the topic of masonry on both design of new structures (EN1998-1) and assessment of existing structures (EN1998-3). The aim is to elaborate suggestions for amendments which fit the current state of the art in masonry and earthquake-resistant design. Focus will be on modelling, simplified methods, linear-analysis (q-values, overstrength-values), nonlinear procedures, out-of-plane design as well as on clearer definition of limit states. Beside these, topics related to general material properties, reinforced masonry, confined masonry, mixed structures and non-structural infills will be covered too. This paper presents the preliminary work and results up to the submission date.
Optical flow estimation is known from Computer Vision where it is used to determine obstacle movements through a sequence of images following an assumption of brightness conservation. This paper presents the first study on application of the optical flow method to aerated stepped spillway flows. For this purpose, the flow is captured with a high-speed camera and illuminated with a synchronized LED light source. The flow velocities, obtained using a basic Horn–Schunck method for estimation of the optical flow coupled with an image pyramid multi-resolution approach for image filtering, compare well with data from intrusive conductivity probe measurements. Application of the Horn–Schunck method yields densely populated flow field data sets with velocity information for every pixel. It is found that the image pyramid approach has the most significant effect on the accuracy compared to other image processing techniques. However, the final results show some dependency on the pixel intensity distribution, with better accuracy found for grey values between 100 and 150.
Autoradiography is a well-established method of nuclear imaging. When different radionuclides are present simultaneously, additional processing is needed to distinguish distributions of radionuclides. In this work, a method is presented where aluminium absorbers of different thickness are used to produce images with different cut-off energies. By subtracting images pixel-by-pixel one can generate images representing certain ranges of β-particle energies. The method is applied to the measurement of irradiated reactor graphite samples containing several radionuclides to determine the spatial distribution of these radionuclides within pre-defined energy windows. The process was repeated under fixed parameters after thermal treatment of the samples. The greyscale images of the distribution after treatment were subtracted from the corresponding pre-treatment images. Significant changes in the intensity and distribution of radionuclides could be observed in some samples. Due to the thermal treatment parameters the most significant differences were observed in the ³H and ¹⁴C inventory and distribution.