Article
Refine
Year of publication
- 2021 (109) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (39)
- IfB - Institut für Bioengineering (27)
- Fachbereich Wirtschaftswissenschaften (16)
- INB - Institut für Nano- und Biotechnologien (15)
- Fachbereich Luft- und Raumfahrttechnik (12)
- Fachbereich Chemie und Biotechnologie (11)
- Fachbereich Bauingenieurwesen (8)
- Fachbereich Energietechnik (7)
- Fachbereich Elektrotechnik und Informationstechnik (6)
- Fachbereich Maschinenbau und Mechatronik (4)
Document Type
- Article (109) (remove)
Keywords
- Principal component analysis (2)
- capacitive field-effect sensor (2)
- constructive alignment (2)
- examination (2)
- harmonic radar (2)
- long-term retention (2)
- multimodal (2)
- practical learning (2)
- Aircraft sizing (1)
- AlterG (1)
- Architektur (1)
- Authenticity (1)
- Bacillus sp (1)
- Bemessung (1)
- Biosolubilization (1)
- Bloom’s Taxonomy (1)
- Bone quality and biomechanics (1)
- Bootstrap (1)
- Boundary integral equations (1)
- CFD (1)
- Capacitive field-effect sensor (1)
- CellDrum (1)
- Competence Developing Games (1)
- DLR-ESTEC GOSSAMER roadmap for solar sailing (1)
- Deuterated solvents (1)
- Deuterium NMR (1)
- Deutschland (1)
- Drinfeld modules (1)
- Earthquake (1)
- Empirical process (1)
- Environmental impact (1)
- Erdbebeneinwirkung (1)
- Frame structure (1)
- Frequency mixing magnetic detection (1)
- Functional Delta Method (1)
- GOSSAMER-1 (1)
- Game-based learning (1)
- Glaucoma (1)
- Hadamard differentiability (1)
- Helmholtz equation (1)
- Heparin (1)
- Hyperdifferentials (1)
- IR (1)
- IR spectroscopy (1)
- IT security education (1)
- Interior Neumann eigenvalues (1)
- Keyword analysis (1)
- LPS (1)
- Label-free detection (1)
- Langevin theory (1)
- Linear discriminant analysis (1)
- MUT measurement; scanner (1)
- Magnetic nanoparticles (1)
- Manufacturer (1)
- Mauerwerksbauten (1)
- Micromagnetic simulation (1)
- Modelica (1)
- Multi-storey (1)
- Muscle Fascicle (1)
- Muscle Force (1)
- Nonequilibrium dynamics (1)
- Numerics (1)
- Ocular blood flow (1)
- Paired sample (1)
- Parasitic drag (1)
- Piping (1)
- Plant virus (1)
- Potential theory (1)
- Powertrain (1)
- PushoverAnalysen (1)
- RVA (1)
- Radar (1)
- SFCW (1)
- Septic cardiomyopathy (1)
- Simulation (1)
- Skeletal muscle (1)
- Small Aral Sea (1)
- Small spacecraft (1)
- Soft independent modeling of class analogy (1)
- Solar sail (1)
- Standardization (1)
- Stiffness (1)
- TMV adsorption (1)
- Tank (1)
- Ta₂O₅ gate (1)
- Tendon Rupture (1)
- Tendons (1)
- Tobacco mosaic virus (TMV) (1)
- Transcendence (1)
- UAV (1)
- Ultrasound (1)
- VOP compression (1)
- Vascular response (1)
- Verhaltensbeiwerte (1)
- Visual field asymmetry (1)
- Wasserbau (1)
- Wasserwirtschaft (1)
- Zeta potential (1)
- acetoin (1)
- acetoin reductase (1)
- actin cytoskeleton (1)
- actuator-sensor system (1)
- alcoholic beverages (1)
- autonomous navigation (1)
- bioburdens (1)
- biosensors (1)
- body imaging at UHF MRI (1)
- building energy modelling (1)
- building energy simulation (1)
- business culture (1)
- capacitive EIS sensor (1)
- capacitive electrolyte–insulator–semiconductor sensors (1)
- capacitive field-effect sensors (1)
- cardiomyocyte biomechanics (1)
- change (1)
- colorization (1)
- control gate (1)
- crop yield (1)
- cyber-physical production systems (1)
- detection of charged macromolecules (1)
- digital factory (1)
- drop jump (1)
- ecological structure (1)
- enzymatic biosensor (1)
- enzyme kinetics (1)
- equivalent circuit (1)
- event-based simulation (1)
- field-effect sensor (1)
- frequency mixing magnetic detection (1)
- gait (1)
- genetic algorithm (1)
- global optimization (1)
- gold nanoparticles (1)
- graphene oxide (1)
- harmonic radar tags (1)
- heat demand (1)
- heat transfer coefficient (1)
- humic acid (1)
- hyper-gravity (1)
- hypo-gravity (1)
- industrial agents (1)
- integrated transmit coil arrays (1)
- intraclass correlation coefficient (1)
- large-scale inspection (1)
- layer-by-layer technique (1)
- light-addressable electrode (1)
- light-addressable potentiometric sensor (1)
- lignite (1)
- locomotion (1)
- low-rank coal (1)
- magnetic nanoparticles (1)
- management (1)
- metagenomics (1)
- microbial diversity (1)
- microfluidics (1)
- microwave measurements (1)
- mobile manipulation (1)
- motivation (1)
- multi-agent systems (1)
- multianalyte detection (1)
- multiplex detection (1)
- muscle fascicle behavior (1)
- muscle mechanics (1)
- nanomaterials (1)
- nonlinear VNA measurements (1)
- nonlinear radar (1)
- on-chip integrated addressable EISCAP sensors (1)
- parabolic flight (1)
- penicillin (1)
- penicillinase (1)
- photoelectrochemistry (1)
- plant virus detection (1)
- polyaniline (1)
- polystyrene sulfonate (1)
- qNMR (1)
- rehabilitation (1)
- running (1)
- sarcomere operating length (1)
- series elastic element behavior (1)
- shotgun sequencing (1)
- shoulder (1)
- soil amendment (1)
- soil health (1)
- soil remediation (1)
- sprint start (1)
- standard error of measurement (1)
- sterility tests (1)
- sterilization efficacy (1)
- sterilization methods (1)
- stochastic optimization (1)
- stretch reflex (1)
- surface-orthogonal path planning (1)
- t-modules (1)
- test-retest reliability (1)
- titanium dioxide photoanode (1)
- tobacco mosaic virus (TMV) (1)
- transponder (1)
- ultrasonography (1)
- ultrasound imaging (1)
- unloading (1)
- validation methods (1)
- walking (1)
- wind turbine production (1)
Aneurysmal subarachnoid hemorrhage (aSAH) is associated with early and delayed brain injury due to several underlying and interrelated processes, which include inflammation, oxidative stress, endothelial, and neuronal apoptosis. Treatment with melatonin, a cytoprotective neurohormone with anti-inflammatory, anti-oxidant and anti-apoptotic effects, has been shown to attenuate early brain injury (EBI) and to prevent delayed cerebral vasospasm in experimental aSAH models. Less is known about the role of endogenous melatonin for aSAH outcome and how its production is altered by the pathophysiological cascades initiated during EBI. In the present observational study, we analyzed changes in melatonin levels during the first three weeks after aSAH.
Performing tasks, such as running and jumping, requires activation of the agonist and antagonist muscles before (motor unit pre-activation) and during movement performance (Santello and Mcdonagh, 1998). A well-timed and regulated muscle activation elicits a stretch-shortening cycle (SSC) response, naturally occurring in bouncing movements (Ishikawa and Komi, 2004; Taube et al., 2012). By definition, the SSC describes the stretching of a pre-activated muscle-tendon complex immediately followed by a muscle shortening in the concentric push-off phase (Komi, 1984).
Given the importance of SSC actions for human movement, it is not surprising that many studies investigated the biomechanics of this phenomenon; in particular, drop jumps (DJs) represent a good paradigm to study muscle fascicle and tendon behavior in ballistic movements involving the SSC.
Within a DJ, three main phases [pre-activation, braking, and push-off (PO; Komi, 2000)] have been recognized and extensively studied in common and challenging conditions, such as changes in load, falling height, or simulated hypo-gravity (Avela et al., 1994; Arampatzis et al., 2001; Fukashiro et al., 2005; Ishikawa et al., 2005; Sousa et al., 2007; Ritzmann et al., 2016; Helm et al., 2020).
These studies show that the timing and amount of triceps-surae muscle-tendon unit pre-activation in DJs are differentially regulated based on the load applied to the muscle, being optimal in normal “Earth” gravity conditions (Avela et al., 1994), but decreased in simulated hypo-gravity, hyper-gravity (Avela et al., 1994; Ritzmann et al., 2016), or unknown conditions (i.e., unknown falling heights; Helm et al., 2020). Some authors indicated that, when falling from heights different from the optimal one [defined as the drop height giving a maximum DJ performance indicated as peak ground reaction force (GRF) or jump high], electromyographic (EMG) activity of the plantar flexors increases from lower than optimal to higher than optimal heights (Ishikawa and Komi, 2004; Sousa et al., 2007).
These findings highlight the ability of the central nervous system to regulate the timing and amount of pre-activation according to different jumping conditions, thus regulating muscle fascicle length, tendon and joint stiffness as well as position, in order to safely land on the ground and quickly re-bounce.
Similarly, to pre-activation, also in the braking phase, the plantar flexors are differentially regulated. In optimal height (i.e., load) jumping conditions, gastrocnemius medialis (GM) fascicles shorten at early ground contact (possibly due to the intervention of the stretch reflex; Gollhofer et al., 1992) and behave quasi-isometrically in the late braking phase, enabling tendon elongation, and storage of elastic energy (Gollhofer et al., 1992; Fukashiro et al., 2005; Sousa et al., 2007). When increasing the falling height (augmenting the impact GRF), the quasi-isometric behavior of fascicles disappears, and fast fascicle lengthening occurs (Ishikawa et al., 2005; Sousa et al., 2007).
In the third and last PO phase, fascicles shorten and the tendon releases the elastic energy previously stored. Bobbert et al. (1987) reported no influence of jumping height on the work done and on the net vertical impulse assessed during PO; this observation suggests that, despite an optimal DJ performance might be achieved only in specific conditions (falling heights, loads), the central nervous system seems to be able to regulate muscle behavior in order to effectively perform the required task also in challenging situations.
Although the regulation of triceps-surae muscle-tendon unit in DJs has been extensively investigated, very few studies focused on sarcomeres behavior during the performance of this SSC movement (Kurokawa et al., 2003; Fukashiro et al., 2005, 2006). Sarcomeres represent muscle contractile units and are known to express different amounts of force depending on their length (Gordon et al., 1966; Walker and Schrodt, 1974); thus, understanding the time course of their responses during DJs is fundamental to gain further insights into muscle force-generating capacity. In vivo measurement of sarcomere length in humans has been so far been performed only in static positions and under highly controlled experimental conditions (Llewellyn et al., 2008; Sanchez et al., 2015). Instead, human sarcomere length estimation (achieved by dividing GM measured fascicle length for a fixed sarcomere number) in dynamic contractions provided an indirect measure of sarcomere operating range during squat jump, countermovement jump, and DJ (Fukashiro et al., 2005, 2006; Kurokawa et al., 2003). The results of these studies showed that sarcomeres operate in the ascending limb of their length-tension (L-T) relationship in all types of jumps, and particularly so in DJ.
However, most of the available observations on sarcomere and muscle fascicle behavior were made in condition of constant gravity. Thus, in order to understand how sarcomere and muscle fascicle length are regulated in variable gravity conditions, we performed experiments in a parabolic flight, involving variable gravity levels, ranging from about zero-g to about double the Earth’s gravity (1 g; Waldvogel et al., 2021).
Specifically, the aims of the present study were as follows:
1. To investigate the ability of the neuromuscular system in regulating fascicle length in response to conditions of variable gravity.
2. To estimate sarcomere operative length in the different DJ phases, in order to calculate its theoretical force production and its possible modulation in conditions of variable gravity.
We hypothesized that muscle fascicles would be differentially regulated in different gravity conditions compared to 1 g, particularly in anticipation of landing and re-bouncing in unknown gravity levels. In addition, we hypothesized that sarcomeres would operate in the upper part of the ascending limb of their L-T relationship, possibly lengthening during the braking phase (especially in hyper-gravity) while operating quasi-isometrically in 1 g.
Quantitative nuclear magnetic resonance (qNMR) is routinely performed by the internal or external standardization. The manuscript describes a simple alternative to these common workflows by using NMR signal of another active nuclei of calibration compound. For example, for any arbitrary compound quantification by NMR can be based on the use of an indirect concentration referencing that relies on a solvent having both 1H and 2H signals. To perform high-quality quantification, the deuteration level of the utilized deuterated solvent has to be estimated.
In this contribution the new method was applied to the determination of deuteration levels in different deuterated solvents (MeOD, ACN, CDCl3, acetone, benzene, DMSO-d6). Isopropanol-d6, which contains a defined number of deuterons and protons, was used for standardization. Validation characteristics (precision, accuracy, robustness) were calculated and the results showed that the method can be used in routine practice. Uncertainty budget was also evaluated. In general, this novel approach, using standardization by 2H integral, benefits from reduced sample preparation steps and uncertainties, and can be applied in different application areas (purity determination, forensics, pharmaceutical analysis, etc.).
Quantitative nuclear magnetic resonance (qNMR) is considered as a powerful tool for multicomponent mixture analysis as well as for the purity determination of single compounds. Special attention is currently paid to the training of operators and study directors involved in qNMR testing. To assure that only qualified personnel are used for sample preparation at our GxP-accredited laboratory, weighing test was proposed. Sixteen participants performed six-fold weighing of the binary mixture of dibutylated hydroxytoluene (BHT) and 1,2,4,5-tetrachloro-3-nitrobenzene (TCNB). To evaluate the quality of data analysis, all spectra were evaluated manually by a qNMR expert and using in-house developed automated routine. The results revealed that mean values are comparable and both evaluation approaches are free of systematic error. However, automated evaluation resulted in an approximately 20% increase in precision. The same findings were revealed for qNMR analysis of 32 compounds used in pharmaceutical industry. Weighing test by six-fold determination in binary mixtures and automated qNMR methodology can be recommended as efficient tools for evaluating staff proficiency. The automated qNMR method significantly increases throughput and precision of qNMR for routine measurements and extends application scope of qNMR.
In this study, a recently proposed NMR standardization approach by 2H integral of deuterated solvent for quantitative multicomponent analysis of complex mixtures is presented. As a proof of principle, the existing NMR routine for the analysis of Aloe vera products was modified. Instead of using absolute integrals of targeted compounds and internal standard (nicotinamide) from 1H-NMR spectra, quantification was performed based on the ratio of a particular 1H-NMR compound integral and 2H-NMR signal of deuterated solvent D2O. Validation characteristics (linearity, repeatability, accuracy) were evaluated and the results showed that the method has the same precision as internal standardization in case of multicomponent screening. Moreover, a dehydration process by freeze drying is not necessary for the new routine. Now, our NMR profiling of A. vera products needs only limited sample preparation and data processing. The new standardization methodology provides an appealing alternative for multicomponent NMR screening. In general, this novel approach, using standardization by 2H integral, benefits from reduced sample preparation steps and uncertainties, and is recommended in different application areas (purity determination, forensics, pharmaceutical analysis, etc.).