Article
Refine
Year of publication
Document Type
- Article (117) (remove)
Has Fulltext
- no (117) (remove)
Keywords
- damage (2)
- Anastomotic leakage (1)
- Autolysis (1)
- Biocomposites (1)
- Cardiac myocytes (1)
- Cardiac tissue (1)
- CellDrum (1)
- Computational biomechanics (1)
- Constitutive model (1)
- Damage mechanics theory (1)
- Decomposition (1)
- Discontinuous fractures (1)
- Distorsion des oberen Sprunggelenks (1)
- Drug simulation (1)
- ES-FEM (1)
- Electromechanical modeling (1)
- End-to-end colorectal anastomosis (1)
- FS-FEM (1)
- Finite element analysis (1)
- Finite element modelling (1)
- Freeze–thaw process (1)
- Frequency adaption (1)
- Heart tissue culture (1)
- Hodgkin–Huxley models (1)
- Homogenization (1)
- Induced pluripotent stem cells (1)
- Inotropic compounds (1)
- Ion channels (1)
- Liver (1)
- Natural fibres (1)
- Non-parallel fissures (1)
- Pharmacology (1)
- Polymer-matrix composites (1)
- S-FEM (1)
- Spleen (1)
- Sprunggelenkorthesen (1)
- Stress concentrations (1)
- Surgical staplers (1)
- Uniaxial compression test (1)
- Variable height stapler design (1)
- anaesthetic complications (1)
- anisotropy (1)
- ankle braces (1)
- ankle sprain (1)
- biaxial tensile experiment (1)
- chance constrained programming (1)
- constitutive modeling (1)
- dental trauma (1)
- difficult airway (1)
- distorted element (1)
- double-lumen tube intubation (1)
- fibulare Bandruptur (1)
- hiPS cardiomyocytes (1)
- hyperelastic (1)
- limit analysis (1)
- non-simplex S-FEM elements (1)
- reliability of structures (1)
- rupture of the fibular ligament (1)
- shakedown analysis (1)
- smooth muscle contraction (1)
- stochastic programming (1)
- strain energy function (1)
- videolaryngoscopy (1)
- virgin passive (1)
- viscoelasticity (1)
Institute
Shakedown analysis of two dimensional structures by an edge-based smoothed finite element method
(2010)
Sensitivity of and Influences on the Reliability of an HTR-Module Primary Circuit Pressure Boundary
(1993)
We present an electromechanically coupled computational model for the investigation of a thin cardiac tissue construct consisting of human-induced pluripotent stem cell-derived atrial, ventricular and sinoatrial cardiomyocytes. The mechanical and electrophysiological parts of the finite element model, as well as their coupling are explained in detail. The model is implemented in the open source finite element code Code_Aster and is employed for the simulation of a thin circular membrane deflected by a monolayer of autonomously beating, circular, thin cardiac tissue. Two cardio-active drugs, S-Bay K8644 and veratridine, are applied in experiments and simulations and are investigated with respect to their chronotropic effects on the tissue. These results demonstrate the potential of coupled micro- and macroscopic electromechanical models of cardiac tissue to be adapted to experimental results at the cellular level. Further model improvements are discussed taking into account experimentally measurable quantities that can easily be extracted from the obtained experimental results. The goal is to estimate the potential to adapt the presented model to sample specific cell cultures.
Reliability of the Primary Circuit Pressure Boundary of an HTR-Module under Accident Conditions
(1993)
Surgical reconstruction of the interosseous membrane (IOM) could restore longitudinal forearm stability to avoid persisting disability due to capituloradial and ulnocarpal impingement in Essex Lopresti lesions. This biomechanical study aimed to assess longitudinal forearm stability of intact specimens, after sectioning of the IOM and after reconstruction with a TightRope construct using either a single or double bundle technique.