Article
Refine
Year of publication
- 2013 (137) (remove)
Document Type
- Article (137) (remove)
Has Fulltext
- no (137) (remove)
Keywords
- Bacillus atrophaeus (1)
- Distorsion des oberen Sprunggelenks (1)
- Prozessabläufe (1)
- Prozessmodellierung (1)
- Prozessstandardisierung (1)
- Referenzmodellierung (1)
- Sprunggelenkorthesen (1)
- ankle braces (1)
- ankle sprain (1)
- calorimetric gas sensor (1)
- calorimetric gas sensor;hydrogen peroxide;wireless sensor system (1)
- eTOM (1)
- fibulare Bandruptur (1)
- hydrogen peroxide (1)
- rupture of the fibular ligament (1)
- sterilisation (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (48)
- INB - Institut für Nano- und Biotechnologien (32)
- Fachbereich Chemie und Biotechnologie (24)
- IfB - Institut für Bioengineering (20)
- Fachbereich Wirtschaftswissenschaften (18)
- Fachbereich Elektrotechnik und Informationstechnik (12)
- Fachbereich Energietechnik (12)
- Sonstiges (6)
- Fachbereich Luft- und Raumfahrttechnik (5)
- Fachbereich Bauingenieurwesen (4)
- Fachbereich Gestaltung (3)
- Fachbereich Maschinenbau und Mechatronik (3)
- ECSM European Center for Sustainable Mobility (2)
- Fachbereich Architektur (2)
- Solar-Institut Jülich (1)
Impedance spectroscopy: A tool for real-time in situ monitoring of the degradation of biopolymers
(2013)
Investigation of the degradation kinetics of biodegradable polymers is essential for the development of implantable biomedical devices with predicted biodegradability. In this work, an impedimetric sensor has been applied for real-time and in situ monitoring of degradation processes of biopolymers. The sensor consists of two platinum thin-film electrodes covered by a polymer film to be studied. The benchmark biomedical polymer poly(D,L-lactic acid) (PDLLA) was used as a model system. PDLLA films were deposited on the sensor structure from a polymer solution by using the spin-coating method. The degradation kinetics of PDLLA films have been studied in alkaline solutions of pH 9 and 12 by means of an impedance spectroscopy (IS) method. Any changes in a polymer capacitance/resistance induced by water uptake and/or polymer degradation will modulate the global impedance of the polymer-covered sensor that can be used as an indicator of the polymer degradation. The degradation rate can be evaluated from the time-dependent impedance spectra. As expected, a faster degradation has been observed for PDLLA films exposed to pH 12 solution.
The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the spatial distribution of specific ions on the sensing surface. The conventional chemical imaging system based on the light-addressable potentiometric sensor (LAPS), however, required a long time to obtain a chemical image, due to the slow mechanical scan of a single light beam. For high-speed imaging, a plurality of light beams modulated at different frequencies can be employed to measure the ion concentrations simultaneously at different locations on the sensor plate by frequency division multiplex (FDM). However, the conventional measurement geometry of back-side illumination limited the bandwidth of the modulation frequency required for FDM measurement, because of the low-pass filtering characteristics of carrier diffusion in the Si substrate. In this study, a high-speed chemical imaging system based on front-side-illuminated LAPS was developed, which achieved high-speed spatiotemporal recording of pH change at a rate of 70 frames per second.
Biotechnological downstream processing is usually an elaborate procedure, requiring a multitude of unit operations to isolate the target component. Besides the disadvantageous space-time yield, the risks of cross-contaminations and product loss grow fast with the complexity of the isolation procedure. A significant reduction of unit operations can be achieved by application of magnetic particles, especially if these are functionalized with affinity ligands. As magnetic susceptible materials are highly uncommon in biotechnological processes, target binding and selective separation of such particles from fermentation or reactions broths can be done in a single step. Since the magnetizable particles can be produced from iron salts and low priced polymers, a single-use implementation of these systems is highly conceivable. In this article, the principles of magnetizable particles, their synthesis and functionalization are explained. Furthermore, applications in the area of reaction engineering, microfluidics and downstream processing are discussed focusing on established single-use technologies and development potential.
The concept of an injective affine embedding of the quantum states into a set of classical states, i.e., into the set of the probability measures on some measurable space, as well as its relation to statistically complete observables is revisited, and its limitation in view of a classical reformulation of the statistical scheme of quantum mechanics is discussed. In particular, on the basis of a theorem concerning a non-denseness property of a set of coexistent effects, it is shown that an injective classical embedding of the quantum states cannot be supplemented by an at least approximate classical description of the quantum mechanical effects. As an alternative approach, the concept of quasi-probability representations of quantum mechanics is considered.